Concrete breakout capacity of cast-in-place concrete anchors in early-age concrete

被引:0
|
作者
Winters, James B. [1 ]
Dolan, Charles W. [2 ]
机构
[1] Wyoming Dept Transportat, Cheyenne, WY 82009 USA
[2] Univ Wyoming, Laramie, WY 82071 USA
来源
PCI JOURNAL | 2014年
关键词
Breakout; concrete; early age; insert; strength; TENSILE-STRENGTH; COMPRESSIVE STRENGTH;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
CI 318-08 appendix D, "Anchoring to Concrete," requires a minimum concrete strength of 2500 psi (17 MPa). Precast concrete elements are often stripped at strengths lower than 2500 psi, raising a concern as to whether the ACI equations are applicable for early-age concrete. This paper provides theoretical and experimental validation of the use of inserts in concrete strengths as low as 1000 psi (7 MPa). Theoretical validation is made by examining the gain in tensile and compressive strength of early-age concrete. Experimental validation comprised 78 pullout tests on headed stud assemblies in concrete with an age as young as 12 hours. The work concluded the following: The tensile strength of early-age concrete rises faster than the compressive strength. The pullout strength of the inserts exceed the theoretical capacity predicted by ACI 318-08 appendix D and the PCI Design Handbook: Precast and Prestressed Concrete.
引用
收藏
页码:114 / 131
页数:18
相关论文
共 50 条
  • [41] Cyclic Loading Test for Cast-in-Place Concrete-Filled Hollow Precast Concrete Columns
    Kim, Chang-Soo
    Lim, Woo-Young
    Park, Hong-Gun
    Oh, Jung-Keun
    ACI STRUCTURAL JOURNAL, 2016, 113 (02) : 205 - 215
  • [42] PRECAST CONCRETE AND CAST-IN-PLACE CONCRETE WITH POST-TENSIONING SPEEDS PARKING STRUCTURE CONSTRUCTION
    不详
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1973, 18 (03): : 98 - 99
  • [43] Flexure-shear behavior of precast concrete deck panels with cast-in-place concrete topping
    Dowell, Robert K.
    Auer, Roy
    PCI JOURNAL, 2011, : 60 - 74
  • [45] Flexure-shear behavior of precast concrete deck panels with cast-in-place concrete topping
    Dowell R.K.
    Auer R.
    PCI Journal, 2011, 56 (03): : 60 - 74
  • [46] Comparison of Core and In-Place Compressive Strengths for Early-Age Concrete
    Spalvier, Agustin
    Bittner, James A.
    Hall, Kerry
    Popovics, John S.
    ACI MATERIALS JOURNAL, 2019, 116 (03) : 63 - 72
  • [47] Early-age behavior of concrete overlays on continuously reinforced concrete pavements
    Kim, SM
    Nelson, PK
    Ruiz, M
    Rasmussen, RO
    Turner, D
    PAVEMENT REHABILITATION AND ACCELERATED TESTING 2003: PAVEMENT DESIGN, MANAGEMENT, AND PERFORMANCE, 2003, (1823): : 80 - 92
  • [48] Field study of plastic tube cast-in-place concrete pile
    陈永辉
    曹德洪
    王新泉
    杜海伟
    张霆
    JournalofCentralSouthUniversityofTechnology, 2008, 15(S2) (S2) : 195 - 202
  • [49] Methods for Managing Tolerance Compatibility: Windows in Cast-in-Place Concrete
    Milberg, Colin T.
    Tommelein, Iris D.
    JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT, 2020, 146 (02)
  • [50] Load Testing and Rating of Cast-in-Place Concrete Box Culverts
    Ulger, Tuna
    Okeil, Ayman M.
    Elshoura, Ahmed
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2020, 34 (02)