Coronary Artery Disease: Diagnostic Accuracy of CT Coronary Angiography-A Comparison of High and Standard Spatial Resolution Scanning

被引:79
|
作者
Pontone, Gianluca [1 ]
Bertella, Erika [1 ]
Mushtaq, Saima [1 ]
Loguercio, Monica [1 ]
Cortinovis, Sarah [1 ]
Baggiano, Andrea [1 ]
Conte, Edoardo [1 ]
Annoni, Andrea [1 ]
Formenti, Alberto [1 ]
Beltrama, Virginia [1 ]
Guaricci, Andrea Igoren [2 ]
Andreini, Daniele [1 ,3 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, I-20138 Milan, Italy
[2] Univ Foggia, Dept Cardiol, Foggia, Italy
[3] Univ Milan, Dept Cardiovasc Sci & Community Hlth, Milan, Italy
关键词
64-SLICE COMPUTED-TOMOGRAPHY; IMAGE QUALITY; MDCT; ULTRASOUND; PLAQUE; ECG;
D O I
10.1148/radiol.13130909
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the image quality, evaluability, diagnostic accuracy, and radiation exposure of high-spatial-resolution (HR, 0.23-mm) computed tomographic (CT) coronary angiography with standard spatial resolution (SR, 0.625-mm) 64-section imaging in patients at high risk for coronary artery disease (CAD) by using invasive coronary angiography (ICA) as the reference method. Materials and Methods: Written informed consent was obtained from all patients, and the study protocol was approved by the institutional ethical committee. Patients at high risk for CAD (n = 184) who were scheduled for ICA were randomly assigned for study with SR (n = 91) or HR (n = 93) coronary CT angiography before they underwent ICA. To compare the two groups, the Student t test or Wilcoxon test were used to evaluate differences in continuous variables. The chi(2) test or Fisher exact test were used, as appropriate, for categorical data. The McNemar test was used to compare the diagnostic performance of coronary CT angiography versus that of ICA in each group. Results: HR coronary CT angiography showed a higher image quality score (3.7 vs 3.4, P < .001) and evaluability (97% vs 92%, P < .002). In a segment-based analysis, HR coronary CT angiography showed a higher specificity, positive predictive value, and accuracy in comparison with SR coronary CT angiography (98%, 91%, and 99% vs 95%, 80%, and 95%, respectively; P < .001). Moreover, HR coronary CT angiography showed a better agreement with ICA for calcified plaques compared with SR coronary CT angiography and ICA (83% vs 53%, P < .001). In a patient-based analysis, HR coronary CT angiography showed higher specificity and accuracy compared with SR coronary CT angiography (91% and 98% vs 46% and 92%, respectively; P < .01). No differences in radiation exposure were found between the two groups. Conclusion: Improved evaluability and accuracy were seen with HR compared with SR coronary CT angiography of calcified coronary artery lesions, suggesting a potential use for this technology in patients at high risk for CAD. (C) RSNA, 2014
引用
收藏
页码:688 / 694
页数:7
相关论文
共 50 条
  • [21] Multislice CT coronary angiography: a new gold-standard for the diagnosis of coronary artery disease?
    de Feyter, Pim J.
    [J]. NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (03): : 132 - 133
  • [22] Comparison of the Diagnostic Accuracy of PET and SPECT for Coronary Artery Disease
    Parker M.W.
    [J]. Current Cardiovascular Imaging Reports, 2015, 8 (1) : 1 - 12
  • [23] WHAT IS DIAGNOSTIC ACCURACY OF 256-ROW CT ANGIOGRAPHY FOR DETECTING OBSTRUCTIVE CORONARY ARTERY DISEASE?
    Rubinshtein, Ronen
    Pechersky, Oleg
    Gaspar, Tamar
    Halon, David A.
    Peled, Nathan
    Lewis, Basil S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E670 - E670
  • [24] Coronary artery abnormalities in Kawasaki disease: comparison between CT and MR coronary angiography
    Kim, Jong Woo
    Goo, Hyun Woo
    [J]. ACTA RADIOLOGICA, 2013, 54 (02) : 156 - 163
  • [25] Coronary CT Angiography for the Detection of Obstructive Coronary Artery Disease
    Maurovich-Horvat P.
    Ghoshhajra B.
    Ferencik M.
    [J]. Current Cardiovascular Imaging Reports, 2010, 3 (6) : 355 - 365
  • [26] Predictive value of coronary CT angiography in coronary artery disease
    Scherrenberg, Martijn
    Scherrenberg, Heleen
    Schoutede, Joren
    Van Droogenbroeck, Lotte
    Vandewinkel, Marie
    [J]. ACTA CARDIOLOGICA, 2020, 75 : 35 - 36
  • [27] Coronary Artery Disease Screening Using CT Coronary Angiography
    Cheong, Randy Wang Long
    See, Brian
    Tan, Benjamin Boon Chuan
    Koh, Choong Hou
    [J]. AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2020, 91 (10) : 812 - 817
  • [28] Coronary CT angiography for patients with suspected coronary artery disease
    Rossi, A.
    Dharampal, A.
    de Feyter, P. J.
    [J]. HEART, 2014, 100 (12) : 976 - 984
  • [29] Coronary CT angiography in coronary artery disease: Opportunities and challenges
    Sun, Zhonghua
    [J]. AUSTRALASIAN MEDICAL JOURNAL, 2016, 9 (05): : 111 - 123
  • [30] High speed versus standard SPECT: improved diagnostic accuracy in patients with coronary artery disease
    Gimelli, A.
    Kusch, A.
    Giorgetti, A.
    Genovesi, D.
    Ferdeghini, E. M.
    Marzullo, P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S248 - S248