Moisture and drug solid-state monitoring during a continuous drying process using empirical and mass balance models

被引:43
|
作者
Fonteyne, Margot [1 ]
Gildemyn, Delphine [1 ]
Peeters, Elisabeth [2 ]
Mortier, Severine Therese F. C. [3 ]
Vercruysse, Jurgen [2 ]
Gernaey, Krist V. [4 ]
Vervaet, Chris [2 ]
Remon, Jean Paul [2 ]
Nopens, Ingmar [3 ]
De Beer, Thomas [1 ]
机构
[1] Univ Ghent, Lab Pharmaceut Proc Analyt Technol, B-9000 Ghent, Belgium
[2] Univ Ghent, Lab Pharmaceut Technol, B-9000 Ghent, Belgium
[3] Univ Ghent, BIOMATH, Dept Math Modelling Stat & Bioinformat, B-9000 Ghent, Belgium
[4] Tech Univ Denmark, Dept Chem & Biochem Engn, DK-2800 Lyngby, Denmark
关键词
NIR spectroscopy; Raman spectroscopy; Real-time monitoring; End-point detection; Granule size fractions; Fluid bed drying; PAT; NEAR-INFRARED SPECTROSCOPY; FLUIDIZED-BED GRANULATOR; TWIN-SCREW GRANULATION; IN-LINE; PHARMACEUTICAL GRANULES; QUALITY ATTRIBUTES; HYDRATE FORMATION; END-POINT; SCALE-UP; POLYMORPHISM;
D O I
10.1016/j.ejpb.2014.02.015
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Classically, the end point detection during fluid bed drying has been performed using indirect parameters, such as the product temperature or the humidity of the outlet drying air. This paper aims at comparing those classic methods to both in-line moisture and solid-state determination by means of Process Analytical Technology (PAT) tools (Raman and NIR spectroscopy) and a mass balance approach. The six-segmented fluid bed drying system being part of a fully continuous from-powder-to-tablet production line (ConsiGma (TM)-25) was used for this study. A theophylline:lactose:PVP (30:67.5:2.5) blend was chosen as model formulation. For the development of the NIR-based moisture determination model, 15 calibration experiments in the fluid bed dryer were performed. Six test experiments were conducted afterwards, and the product was monitored in-line with NIR and Raman spectroscopy during drying. The results (drying endpoint and residual moisture) obtained via the NIR-based moisture determination model, the classical approach by means of indirect parameters and the mass balance model were then compared. Our conclusion is that the PAT-based method is most suited for use in a production set-up. Secondly, the different size fractions of the dried granules obtained during different experiments (fines, yield and oversized granules) were compared separately, revealing differences in both solid state of theophylline and moisture content between the different granule size fractions. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:616 / 628
页数:13
相关论文
共 28 条
  • [21] Monitoring moisture content in parchment coffee beans during drying using Fourier Transform near infrared (FT-NIR) spectroscopy: A dataset for calibrating chemometric-based models for moisture prediction
    Ordonez-Lozano, Sandrith
    Collazos-Escobar, Gentil A.
    Bahamon-Monje, Andres F.
    Gutierrez-Guzman, Nelson
    DATA IN BRIEF, 2025, 59
  • [22] Enhancing the melt stability of polylactide stereocomplexes using a solid-state cross-linking strategy during a melt-blending process
    Bai, Hongwei
    Liu, Huili
    Bai, Dongyu
    Zhang, Qin
    Wang, Ke
    Deng, Hua
    Chen, Feng
    Fu, Qiang
    POLYMER CHEMISTRY, 2014, 5 (20) : 5985 - 5993
  • [23] Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)-Solid-State Ion-Selective Electrodes (S-ISEs)
    Fan, Yingzheng
    Huang, Yuankai
    Linthicum, Will
    Liu, Fangyuan
    Beringhs, Andre O'Reilly
    Dang, Yanliu
    Xu, Zhiheng
    Chang, Shing-Yun
    Ling, Jing
    Huey, Bryan D.
    Suib, Steven L.
    Anson, W. K.
    Gao, Pu-Xian
    Lu, Xiuling
    Lei, Yu
    Shaw, Montgomery T.
    Li, Baikun
    ACS SENSORS, 2020, 5 (10) : 3182 - 3193
  • [24] Optimizing the Formulation and Lyophilization Process for a Fragment Antigen Binding (Fab) Protein Using Solid-State Hydrogen-Deuterium Exchange Mass Spectrometry (ssHDX-MS)
    Kumar, Lokesh
    Chandrababu, Karthik Balakrishna
    Balakrishnan, Shenbaga Moorthy
    Allmendinger, Andrea
    Walters, Benjamin
    Zarraga, Isidro E.
    Chang, Debby P.
    Nayak, Purnendu
    Topp, Elizabeth M.
    MOLECULAR PHARMACEUTICS, 2019, 16 (11) : 4485 - 4495
  • [25] Long-term continuous and real-time in situ monitoring of Pb(II) toxic contaminants in wastewater using solid-state ion selective membrane (S-ISM) Pb and pH auto-correction assembly
    Fan, Yingzheng
    Xu, Zhiheng
    Huang, Yuankai
    Wang, Tianbao
    Zheng, Sikai
    DePasquale, Alex
    Brueckner, Christian
    Lei, Yu
    Li, Baikun
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 400
  • [26] Real-time in situ auto-correction of K+ interference for continuous and long-term NH4+ monitoring in wastewater using solid-state ion selective membrane (S-ISM) sensor assembly
    Wang, Tianbao
    Xu, Zhiheng
    Huang, Yuankai
    Dai, Zheqin
    Wang, Xingyu
    Lee, Meredith
    Bagtzoglou, Christos
    Bruckner, Christian
    Lei, Yu
    Li, Baikun
    ENVIRONMENTAL RESEARCH, 2020, 189
  • [27] Multi-track, multi-layer dendrite growth and solid phase transformation analysis during additive manufacturing of H13 tool steel using a combined hybrid cellular automata/phase field, solid-state phase prediction models
    Neil S. Bailey
    Yung C. Shin
    The International Journal of Advanced Manufacturing Technology, 2022, 120 : 2089 - 2108
  • [28] Multi-track, multi-layer dendrite growth and solid phase transformation analysis during additive manufacturing of H13 tool steel using a combined hybrid cellular automata/phase field, solid-state phase prediction models
    Bailey, Neil S.
    Shin, Yung C.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2022, 120 (3-4): : 2089 - 2108