Moisture and drug solid-state monitoring during a continuous drying process using empirical and mass balance models

被引:43
|
作者
Fonteyne, Margot [1 ]
Gildemyn, Delphine [1 ]
Peeters, Elisabeth [2 ]
Mortier, Severine Therese F. C. [3 ]
Vercruysse, Jurgen [2 ]
Gernaey, Krist V. [4 ]
Vervaet, Chris [2 ]
Remon, Jean Paul [2 ]
Nopens, Ingmar [3 ]
De Beer, Thomas [1 ]
机构
[1] Univ Ghent, Lab Pharmaceut Proc Analyt Technol, B-9000 Ghent, Belgium
[2] Univ Ghent, Lab Pharmaceut Technol, B-9000 Ghent, Belgium
[3] Univ Ghent, BIOMATH, Dept Math Modelling Stat & Bioinformat, B-9000 Ghent, Belgium
[4] Tech Univ Denmark, Dept Chem & Biochem Engn, DK-2800 Lyngby, Denmark
关键词
NIR spectroscopy; Raman spectroscopy; Real-time monitoring; End-point detection; Granule size fractions; Fluid bed drying; PAT; NEAR-INFRARED SPECTROSCOPY; FLUIDIZED-BED GRANULATOR; TWIN-SCREW GRANULATION; IN-LINE; PHARMACEUTICAL GRANULES; QUALITY ATTRIBUTES; HYDRATE FORMATION; END-POINT; SCALE-UP; POLYMORPHISM;
D O I
10.1016/j.ejpb.2014.02.015
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Classically, the end point detection during fluid bed drying has been performed using indirect parameters, such as the product temperature or the humidity of the outlet drying air. This paper aims at comparing those classic methods to both in-line moisture and solid-state determination by means of Process Analytical Technology (PAT) tools (Raman and NIR spectroscopy) and a mass balance approach. The six-segmented fluid bed drying system being part of a fully continuous from-powder-to-tablet production line (ConsiGma (TM)-25) was used for this study. A theophylline:lactose:PVP (30:67.5:2.5) blend was chosen as model formulation. For the development of the NIR-based moisture determination model, 15 calibration experiments in the fluid bed dryer were performed. Six test experiments were conducted afterwards, and the product was monitored in-line with NIR and Raman spectroscopy during drying. The results (drying endpoint and residual moisture) obtained via the NIR-based moisture determination model, the classical approach by means of indirect parameters and the mass balance model were then compared. Our conclusion is that the PAT-based method is most suited for use in a production set-up. Secondly, the different size fractions of the dried granules obtained during different experiments (fines, yield and oversized granules) were compared separately, revealing differences in both solid state of theophylline and moisture content between the different granule size fractions. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:616 / 628
页数:13
相关论文
共 28 条
  • [1] A SOLID-STATE SENSOR FOR CONTINUOUS MONITORING OF HYDROGEN USING SILVER SULFIDE
    NAGASHIMA, K
    SUZUKI, S
    BUNSEKI KAGAKU, 1986, 35 (09) : 826 - 828
  • [2] On-line monitoring of vacuum drying of theophylline using NIR spectroscopy: solid-state transitions, water content and semi-empirical modeling
    Amira, Touil
    Roman, Peczalski
    Fethi, Zagrouba
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2016, 42 (11) : 1825 - 1832
  • [3] Continuous on-line measurement of solid moisture content during fluidized bed drying using triboelectric probes
    Portoghese, Federica
    Berruti, Franco
    Briens, Cedric
    POWDER TECHNOLOGY, 2008, 181 (02) : 169 - 177
  • [4] Monitoring of polypeptide content in the solid-state fermentation process of rapeseed meal using NIRS and chemometrics
    Xing, Zheng
    Hou, Xiaoshan
    Tang, Yingxiu
    He, Ronghai
    Mintah, Benjamin K.
    Dabbour, Mokhtar
    Ma, Haile
    JOURNAL OF FOOD PROCESS ENGINEERING, 2018, 41 (07)
  • [5] Newly designed multi-stacked circular tray solid-state bioreactor: analysis of a distributed parameter gas balance during solid-state fermentation with influence of variable initial moisture content arrangements
    Musaalbakri Abdul Manan
    Colin Webb
    Bioresources and Bioprocessing, 7
  • [6] Newly designed multi-stacked circular tray solid-state bioreactor: analysis of a distributed parameter gas balance during solid-state fermentation with influence of variable initial moisture content arrangements
    Manan, Musaalbakri Abdul
    Webb, Colin
    BIORESOURCES AND BIOPROCESSING, 2020, 7 (01)
  • [7] Determination of total acid content and moisture content during solid-state fermentation processes using hyperspectral imaging
    Zhu, Yaodi
    Zou, Xiaobo
    Shen, Tingting
    Shi, Jiyong
    Zhao, Jiewen
    Holmes, Mel
    Li, Guoquan
    JOURNAL OF FOOD ENGINEERING, 2016, 174 : 75 - 84
  • [8] Monitoring solid-state transformations in theophylline-lactose granules during drying in the multipart microscale fluid bed powder processor
    Kivikero, Niina
    Kogermann, K.
    Strachan, C.
    Savolainen, M.
    Juppo, A.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 34 (01) : S25 - S25
  • [9] Effects of Drying Process on an IgG1 Monoclonal Antibody Using Solid-State Hydrogen Deuterium Exchange with Mass Spectrometric Analysis (ssHDX-MS)
    Moussa, Ehab M.
    Wilson, Nathan E.
    Zhou, Qi Tony
    Singh, Satish K.
    Nema, Sandeep
    Topp, Elizabeth M.
    PHARMACEUTICAL RESEARCH, 2018, 35 (01)
  • [10] Effects of Drying Process on an IgG1 Monoclonal Antibody Using Solid-State Hydrogen Deuterium Exchange with Mass Spectrometric Analysis (ssHDX-MS)
    Ehab M. Moussa
    Nathan E. Wilson
    Qi Tony Zhou
    Satish K. Singh
    Sandeep Nema
    Elizabeth M. Topp
    Pharmaceutical Research, 2018, 35