Linear, logarithmic, and polynomial models of M-mode echocardiographic measurements in dogs

被引:47
|
作者
Gonçalves, AC
Orton, EC
Boon, JA
Salman, MD
机构
[1] Colorado State Univ, Coll Vet Med & Biomed Sci, Dept Clin Sci, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Coll Vet Med & Biomed Sci, Dept Environm Hlth, Ft Collins, CO 80523 USA
关键词
D O I
10.2460/ajvr.2002.63.994
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine whether logarithmic and polynomial models are superior to simple linear models for predicting reference values for M-mode echocardiographic variables in dogs with a wide range of body weights. Animals-69 apparently healthy adult male and female dogs of various breeds, ages (range, 1 to 12 years; median, 3.5 years), and body weights (range, 3.9 to 97.7 kg; median, 25.4 kg). Procedure-Echocardiographic M-mode measurements of the interventricular septum, left ventricular dimension (LVD), left ventricular wall, aorta, and left atrium were obtained. Simple linear, second-order polynomial, third-order polynomial, and logarithmic regression models were determined by use of the least-squares method to describe the relationship between M-mode measurements and body weight. Differences in adjusted R-2 values of logarithmic and polynomial models were tested for significance of contribution, compared with the simple linear model. Results-Significant differences in adjusted R-2 were found when comparing simple linear with logarithmic or polynomial models for LVD-diastole, LVD-systole, aorta, and left atrium. Differences in adjusted R-2 between second-order polynomial, third-order polynomial, and logarithmic models were not significant for any M-mode measurement. Conclusions and Clinical Relevance-In this study, logarithmic or second-order polynomial models predicted reference values of M-mode measurements for size of the cardiac chambers better than simple linear models for dogs with a wide range of body weights. Logarithmic and polynomial models were not superior to simple linear models for M-mode measurements of cardiac wall thickness.
引用
收藏
页码:994 / 999
页数:6
相关论文
共 50 条
  • [31] ON THE EXPLANATION OF THE M-MODE ECHOCARDIOGRAPHIC IMAGE OF AN ATRIAL-MYXOMA
    STEFANADIS, C
    TOUTOUZAS, P
    KREMASTINOS, D
    VASSILIADIS, J
    EUROPEAN HEART JOURNAL, 1985, 6 (10) : 865 - 869
  • [32] M-MODE ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR FUNCTION
    POPP, RL
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (05): : 1312 - 1318
  • [33] Movement track extracting in omnidirectional M-mode echocardiographic image
    Huang Liqin
    Lin Qiang
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 538 - 542
  • [34] Echocardiographic Applications of M-Mode Ultrasonography in Anesthesiology and Critical Care
    Prada, Gabriel
    Vieillard-Baron, Antoine
    Martin, Archer K.
    Hernandez, Antonio
    Mookadam, Farouk
    Ramakrishna, Harish
    Diaz-Gomez, Jose L.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (06) : 1559 - 1583
  • [35] M-MODE ECHOCARDIOGRAPHIC FINDINGS IN CHILDREN WITH IDIOPATHIC RESTRICTIVE CARDIOMYOPATHY
    MEHTA, AV
    FERRER, PL
    PICKOFF, AS
    SINGH, SS
    WOLFF, GS
    TAMER, DS
    GARCIA, OL
    GELBAND, H
    PEDIATRIC CARDIOLOGY, 1984, 5 (04) : 273 - 279
  • [36] M-MODE ECHOCARDIOGRAPHIC FEATURES OF PRIMARY PULMONARY-HYPERTENSION
    THENABADU, PN
    DEEN, M
    ABEYWARDENE, A
    SUMATHIPALA, RW
    CLINICAL RESEARCH, 1980, 28 (02): : A199 - A199
  • [37] NONPROLAPSING LEFT ATRIAL TUMOR - THE M-MODE ECHOCARDIOGRAPHIC DIAGNOSIS
    LEE, YC
    MAGRAM, MY
    CHEST, 1980, 78 (02) : 332 - 333
  • [38] VALIDATION OF M-MODE ECHOCARDIOGRAPHIC DIAMETER OF THE DILATED ASCENDING AORTA
    PYERITZ, RE
    BRINKER, JA
    FORTUIN, NJ
    WEISS, JL
    CLINICAL RESEARCH, 1980, 28 (02): : A204 - A204
  • [39] REPRODUCIBILITY OF M-MODE ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR FUNCTION - SIGNIFICANCE OF THE TEMPORAL RANGE OF MEASUREMENTS
    KUPARI, M
    EUROPEAN HEART JOURNAL, 1984, 5 (05) : 412 - 418
  • [40] REPRODUCIBILITY AND AGREEMENT OF 2D VS M-MODE ECHOCARDIOGRAPHIC LINEAR MEASUREMENTS IN ESTIMATION OF LEFT VENTRICLE MASS IN NORMAL ADULT SUBJECTS
    Rossi, D.
    Alessi, F.
    Campanile, C.
    Pinna, G.
    Forni, G.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24 (SUPPL C)