Linear, logarithmic, and polynomial models of M-mode echocardiographic measurements in dogs

被引:47
|
作者
Gonçalves, AC
Orton, EC
Boon, JA
Salman, MD
机构
[1] Colorado State Univ, Coll Vet Med & Biomed Sci, Dept Clin Sci, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Coll Vet Med & Biomed Sci, Dept Environm Hlth, Ft Collins, CO 80523 USA
关键词
D O I
10.2460/ajvr.2002.63.994
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine whether logarithmic and polynomial models are superior to simple linear models for predicting reference values for M-mode echocardiographic variables in dogs with a wide range of body weights. Animals-69 apparently healthy adult male and female dogs of various breeds, ages (range, 1 to 12 years; median, 3.5 years), and body weights (range, 3.9 to 97.7 kg; median, 25.4 kg). Procedure-Echocardiographic M-mode measurements of the interventricular septum, left ventricular dimension (LVD), left ventricular wall, aorta, and left atrium were obtained. Simple linear, second-order polynomial, third-order polynomial, and logarithmic regression models were determined by use of the least-squares method to describe the relationship between M-mode measurements and body weight. Differences in adjusted R-2 values of logarithmic and polynomial models were tested for significance of contribution, compared with the simple linear model. Results-Significant differences in adjusted R-2 were found when comparing simple linear with logarithmic or polynomial models for LVD-diastole, LVD-systole, aorta, and left atrium. Differences in adjusted R-2 between second-order polynomial, third-order polynomial, and logarithmic models were not significant for any M-mode measurement. Conclusions and Clinical Relevance-In this study, logarithmic or second-order polynomial models predicted reference values of M-mode measurements for size of the cardiac chambers better than simple linear models for dogs with a wide range of body weights. Logarithmic and polynomial models were not superior to simple linear models for M-mode measurements of cardiac wall thickness.
引用
收藏
页码:994 / 999
页数:6
相关论文
共 50 条
  • [1] M-MODE ECHOCARDIOGRAPHIC MEASUREMENTS IN NORMAL CHILEAN SUBJECTS
    OYONARTE, M
    LUKSIC, I
    LAGOS, F
    CUMSILLE, F
    KLENNER, C
    REVISTA MEDICA DE CHILE, 1988, 116 (01) : 34 - 39
  • [2] COMPARISON OF INDEPENDENT AND DERIVED M-MODE ECHOCARDIOGRAPHIC MEASUREMENTS
    PANIDIS, IP
    ROSS, J
    REN, JF
    KOTLER, MN
    MINTZ, GS
    AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (06): : 694 - 696
  • [3] M-mode echocardiographic diagnosis of dilated cardiomyopathy in giant breed dogs
    Koch, J
    Pedersen, HD
    Jensen, AL
    Flagstad, A
    JOURNAL OF VETERINARY MEDICINE SERIES A-ZENTRALBLATT FUR VETERINARMEDIZIN REIHE A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 1996, 43 (05): : 297 - 304
  • [4] Two-dimensional echocardiographic measures of left ventricular dimensions agree with M-mode measurements in dogs
    Rishniw, M.
    Corda, A.
    Spina, F.
    Caivano, D.
    JOURNAL OF VETERINARY CARDIOLOGY, 2021, 33 : 69 - 75
  • [5] STANDARDIZATION OF M-MODE ECHOCARDIOGRAPHIC LEFT-VENTRICULAR ANATOMIC MEASUREMENTS
    DEVEREUX, RB
    LUTAS, EM
    CASALE, PN
    KLIGFIELD, P
    EISENBERG, RR
    HAMMOND, IW
    MILLER, DH
    REIS, G
    ALDERMAN, MH
    LARAGH, JH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (06) : 1222 - 1230
  • [6] M-MODE ECHOCARDIOGRAPHIC VALUES IN SHEEP
    MOSES, BL
    ROSS, JN
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1987, 48 (09) : 1313 - 1318
  • [7] Reference Values of M-mode Echocardiographic Parameter in Adult Toy Breed Dogs
    Isayama, Noriko
    Uchimura, Yusuke
    Sasaki, Kenta
    Maeda, Erika
    Takahashi, Toshihisa
    Watanabe, Megumi
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [8] Echocardiographic evaluation of the left atrium of healthy dogs using the conventional M-mode and the bidimensional mode
    Prada, D. G.
    Oliveira, V. M. C.
    Larsson, M. H. M. A.
    Yamaki, F. L.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2012, 64 (03) : 585 - 592
  • [9] REPRODUCIBILITY OF M-MODE VERSUS 2D LINEAR ECHOCARDIOGRAPHIC MEASUREMENTS IN PATIENTS WITH LEFT VENTRICULAR DYSFUNCTION
    Rossi, D.
    Alessi, F.
    Pinna, G.
    Traversi, E.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0G) : G167 - G168
  • [10] RECOMMENDATIONS REGARDING QUANTITATION IN M-MODE ECHOCARDIOGRAPHY - RESULTS OF A SURVEY OF ECHOCARDIOGRAPHIC MEASUREMENTS
    SAHN, DJ
    DEMARIA, A
    KISSLO, J
    WEYMAN, A
    CIRCULATION, 1978, 58 (06) : 1072 - 1083