One-Year Outcomes from the TAXUS Express Stent Versus Cypher Stent

被引:11
|
作者
Mayor, Manuel [2 ]
Malik, Amir Z. [3 ]
Minor, Robert J., Jr. [4 ]
Deshpande, Mahesh C. [5 ]
Strauss, William E. [5 ]
Maloney, Thomas H. [5 ]
Baim, Donald S. [5 ]
O'Neill, William [2 ]
Kandzari, David E. [1 ]
机构
[1] Scripps Clin, La Jolla, CA 92037 USA
[2] Univ Miami, Miami, FL USA
[3] Heart Ctr N Texas, Ft Worth, TX USA
[4] OSF St Anthony Med Ctr, Rockford, IL USA
[5] Boston Sci Corp, Natick, MA USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2009年 / 103卷 / 07期
关键词
PACLITAXEL-ELUTING STENTS; BARE-METAL STENTS; RANDOMIZED CONTROLLED-TRIAL; CORONARY-ARTERY-DISEASE; DIABETIC-PATIENTS; POOLED ANALYSIS; REAL-WORLD; SIROLIMUS; MELLITUS; RESTENOSIS;
D O I
10.1016/j.amjcard.2008.11.052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared 1-year outcomes in patients treated with paclitaxel-eluting stents (PESs) or sirolimus-eluting stents (SESs) in "real-world" clinical practice. Clinical outcomes were evaluated in 1,558 consecutive, unselected, retrospectively collected patients treated with drug-eluting stents (DESs; PES = 816, SES = 742) at 1.9 United States centers. The primary end point was 1-year target vessel revascularization (TVR). The study included a prespecified diabetic cohort (PES = 289, SES = 247), for which efficacy comparisons between DESs were analyzed according to vessel diameter and presence of chronic kidney disease. Baseline demographic, angiographic, and procedural characteristics were similar between patients treated with PESs and those treated with SESs. At I year, there were no overall statistical differences in death, myocardial infarction, TVR, or stent thrombosis. In the diabetic cohort, however, the cumulative incidence of TVR was significantly lower for patients treated with PESs (3%) compared with SESs (9%, p <0.01), which persisted after adjustment for baseline differences (hazard ratio 0.29, 95% confidence interval 0.12 to 0.67). This decrease in TVR with PES was similar in insulin- and noninsulin-requiring diabetic patients. In multivariate analysis, independent predictors of TVR included diabetes, bifurcation stenting, and overlapping stents; in the diabetic cohort, treatment with. SESs was also a multivariate predictor of TVR. In conclusion, in this observational, retrospective analysis of DES-treated patients, PESs and SESs demonstrated similar overall safety and efficacy, but PESs were associated with a significant decrease in 1-year TVR rates in diabetic patients. (C) 2009 Elsevier Inc. (Am J Cardiol 2009;103:930-936)
引用
收藏
页码:930 / 936
页数:7
相关论文
共 50 条
  • [31] A volumetric intravascular ultrasound comparison of Cypher and Taxus in-stent restenosis.
    Ohlmann, P
    Kim, SW
    Mintz, GS
    Escolar, E
    Pichard, AD
    Satler, LF
    Kent, KM
    Suddath, WO
    Waksman, R
    Weissman, NJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 71D - 71D
  • [32] Five-year outcomes of Cypher™ coronary stent: report from J-PMS Study
    Jun-ichi Kotani
    Yuji Ikari
    Eisho Kyo
    Masato Nakamura
    Hiroyoshi Yokoi
    Kiyohiro Furuno
    Hideaki Inui
    Ken Kozuma
    Cardiovascular Intervention and Therapeutics, 2012, 27 (2) : 63 - 71
  • [33] New Study suggests Better Patient Outcomes with Cypher Sirolimus-Eluting Coronary Stent than with Taxus Stent in Real -World Clinical Settings
    不详
    JOURNAL FUR KARDIOLOGIE, 2007, 14 (7-8): : 249 - 249
  • [34] Economic Modeling of New Stent Platforms to Evaluate Cost Effectiveness: Analysis of the TAXUS Liberte Versus TAXUS Express Stents
    Turco, Mark A.
    Kansal, Anuraag R.
    Stern, Sean
    Amorosi, Stacey L.
    Underwood, Paul L.
    De Lissovoy, Greg
    Dawkins, Keith D.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (04) : 353 - 363
  • [35] Sirolimus eluting stent (Cypher™) in patients with diabetes mellitus:: results from the German Cypher Stent Registry
    Weber, Frank D.
    Schneider, Henrik
    Wiemer, Marcus
    Pfannebecker, Thomas
    Tebbe, Ulrich
    Hamm, Christian W.
    Senges, Jochen
    Schneider, Steffen
    Nienaber, Christoph A.
    CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (02) : 105 - 109
  • [36] One-year outcomes from an international study of the Ovation Abdominal Stent Graft System for endovascular aneurysm repair
    Mehta, Manish
    Valdes, Francisco E.
    Nolte, Thomas
    Mishkel, Gregory J.
    Jordan, William D.
    Gray, Bruce
    Eskandari, Mark K.
    Botti, Charles
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (01) : 65 - U122
  • [37] Sirolimus eluting stent (Cypher™) in patients with diabetes mellitus: results from the German Cypher Stent Registry
    Frank D. Weber
    Henrik Schneider
    Marcus Wiemer
    Thomas Pfannebecker
    Ulrich Tebbe
    Christian W. Hamm
    Jochen Senges
    Steffen Schneider
    Christoph A. Nienaber
    Clinical Research in Cardiology, 2008, 97 : 105 - 109
  • [38] Sirolimus coated stent versus bare stent:: Angiographic and IVUS analysis at four-month and one-year follow-up
    Feres, E
    Abizaid, A
    Alvaréz, G
    Stalco, R
    Pinto, I
    Mattos, LA
    Seixas, AC
    Tanajura, LK
    Chaves, A
    Centemero, M
    Abizaid, A
    Falotico, R
    Jaeger, J
    Sousa, A
    Sousa, JE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 59A - 59A
  • [39] One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS Stent the TAXUS-IV trial
    Stone, GW
    Ellis, SG
    Cox, DA
    Hermiller, J
    O'Shaughnessy, C
    Mann, JT
    Turco, M
    Caputo, R
    Bergin, P
    Greenberg, J
    Popma, JJ
    Russell, ME
    CIRCULATION, 2004, 109 (16) : 1942 - 1947
  • [40] One-year outcomes of patients with the zotarolimus-eluting coronary stent: RESOLUTE International Registry
    Neumann, Franz-Josef
    Widimsky, Petr
    Belardi, Jorge A.
    EUROINTERVENTION, 2012, 7 (10) : 1181 - 1188