Identification of the slow wave of small bowel myoelectrical activity by surface recording

被引:0
|
作者
Martínez-de-Juan, JL [1 ]
Saiz, FJ [1 ]
Silvestre, J [1 ]
Ponce, JL [1 ]
机构
[1] Univ Politecn Valencia, Dept Ingn Electron, Grp Bioelectron, Valencia, Spain
关键词
surface recording; electroenterogram; small bowel; myoelectrical activity;
D O I
10.1109/IEMBS.2001.1020629
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The bioelectrical signal (electroenterogram) is recorded at the abdominal surface of Beagle dogs with the aim of detecting the slow wave of small bowel myoelectrical activity. Electroenterogram comprises two signals: the slow wave, which is permanently present and establishes the maximum rate of intestinal contraction, and a series of rapid activity peaks generated at the plateau of the slow wave when the small bowel contracts. Two biosignals were recorded using bipolar electrodes: the internal myoelectric signal at a point of the jejunum serosa, and the bioelectric signal at the abdominal wall. The coherence function was used to evaluate the relation between the spectral contents of the two signals (internal and external). The results show high coherence function values for frequencies of under 2 Hz. A maximum was even detected for a frequency round 0.3 Hz, corresponding to the frequency of the slow wave (between 16 and 19 cycles/min.). Based on the coherence function, it is shown that the signal recorded at the abdominal surface is closely related to the slow wave component of the internal signal. The model employed therefore offers a noninvasive technique for recording small bowel myoelectrical activity.
引用
收藏
页码:2024 / 2027
页数:4
相关论文
共 50 条
  • [32] AN INTRALUMINAL PROBE FOR RECORDING MYOELECTRICAL ACTIVITY OF THE HUMAN-COLON
    FIORAMONTI, J
    BUENO, L
    FREXINOS, J
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1980, 4 (8-9): : 546 - 550
  • [33] DEVELOPMENT OF METHODOLOGY FOR RECORDING COLONIC MYOELECTRICAL ACTIVITY IN THE INFANT PRIMATE
    CANNON, RA
    CHEUNG, ATW
    BIOMATERIALS ARTIFICIAL CELLS AND ARTIFICIAL ORGANS, 1989, 17 (01): : 81 - 92
  • [34] Gastric myoelectrical activity post-chemoradiotherapy and esophagectomy: a prospective study using subscapular surface recording
    Lawlor, PM
    McCullough, JA
    Byrne, PJ
    Reynolds, JV
    DISEASES OF THE ESOPHAGUS, 2004, 17 (01) : 76 - 80
  • [35] Stationarity study of the myoelectrical signal recorded from small bowel
    Garcia-Casado, J
    Marinez-De-Juan, JL
    Meseguer, M
    Ponce, JL
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 110 - 113
  • [36] Altered small bowel pacemaker activity in idiopathic slow transit constipation
    Mccourtney, J
    Muir, T
    Hemingway, D
    Finlay, I
    GUT, 1999, 44 : A78 - A78
  • [37] CONFIGURATION AND FREQUENCY GRADIENT OF ELECTRIC SLOW WAVE OVER CANINE SMALL BOWEL
    SZURSZEW.JH
    ELVEBACK, LR
    CODE, CF
    AMERICAN JOURNAL OF PHYSIOLOGY, 1970, 218 (05): : 1468 - &
  • [38] EFFECT OF COHERIN ON COLONIC MYOELECTRICAL ACTIVITY IN IRRITABLE BOWEL SYNDROME
    SNAPE, WJ
    SULLIVAN, MA
    COHEN, S
    GASTROENTEROLOGY, 1978, 74 (05) : 1097 - 1097
  • [39] SIMULTANEOUS RECORDING OF MYOELECTRICAL ACTIVITY AND RESISTANCE FROM THE HUMAN-COLON
    MORRIS, IR
    HAMMOND, P
    DARBY, C
    TAYLOR, I
    DIGESTION, 1983, 26 (01) : 33 - 42
  • [40] CONSTRUCTION OF WIRE LEADS AND ELECTRODES FOR USE IN SLOW-WAVE RECORDING IN SMALL ANIMALS
    COOLEY, RK
    VANDERWOLF, CH
    BRAIN RESEARCH BULLETIN, 1978, 3 (02) : 175 - 179