Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

被引:5
|
作者
Croft, Stephen [1 ]
Burr, Tom [2 ]
Favalli, Andrea [3 ]
Nicholson, Andrew [1 ]
机构
[1] Oak Ridge Natl Lab, One Bethel Valley Rd, Oak Ridge, TN USA
[2] IAEA, A-1400 Vienna, Austria
[3] Los Alamos Natl Lab, MS E540, Los Alamos, NM 87545 USA
关键词
Neutron collar; Fresh LWR fuel assay; Linear regression; Errors in predictor; UNCERTAINTY;
D O I
10.1016/j.nima.2015.11.154
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The declared linear density of U-238 and U-235 in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of U-235 (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This paper compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. We find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters. Published by Elsevier B.V.
引用
收藏
页码:70 / 75
页数:6
相关论文
共 29 条
  • [21] ESTIMATION OF NEUTRON-ACTIVATION ANALYSIS ERRORS CAUSED BY NEUTRON-FIELD DEPRESSION AND BY COINCIDENCE OF THE ENERGIES OF THE NEUTRON-CAPTURE RESONANCE LEVELS OF THE NUCLIDES ANALYZED AND INTERFERING ELEMENTS
    KISELEVA, TT
    FIRSOV, VI
    SHULEPNIKOV, MN
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1982, 37 (06): : 778 - 783
  • [22] Isotopic ratio of 129I/127I in seaweed measured by neutron activation analysis with γ-γ coincidence
    Toh, Y
    Hatsukawa, Y
    Oshima, M
    Shinohara, N
    Hayakawa, T
    Kushita, K
    Ueno, T
    HEALTH PHYSICS, 2002, 83 (01): : 110 - 113
  • [23] Regression analysis of coincidence measurements for determinating the neutron emission rate of 252Cf spontaneous fission
    Li Yong-Ming
    Wang Liang
    Chen Xiang-Lin
    Ruan Nian-Show
    Zhao De-Shan
    ACTA PHYSICA SINICA, 2018, 67 (24)
  • [24] Using the JCC-71 neutron coincidence collar as a benchmark for detector characterization with PTR-32 list mode data acquisition
    Simone, A. T.
    Croft, S.
    Hayward, J. P.
    Worrall, L. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 908 : 24 - 34
  • [25] A proposed semi-empirical method for 235U mass calibration of the active-well neutron coincidence counter
    El-Gammal, W.
    Zidan, W. I.
    Elhakim, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (02): : 731 - 741
  • [26] Neutron coincidence counting based on time interval analysis with one- and two-dimensional Rossi-alpha distributions: An application for passive neutron waste assay
    Bruggeman, M
    Baeten, P
    DeBoeck, W
    Carchon, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03): : 511 - 518
  • [27] Epithermal instrumental neutron activation analysis for the determination of gold and arsenic in Ghanaian gold tailings using conventional and anti-coincidence counting
    B. J. B. Nyarko
    Y. Serfor-Armah
    J. Holzbecher
    E. K. Osae
    E. H. K. Akaho
    D. Carboo
    A. Chatt
    Journal of Radioanalytical and Nuclear Chemistry, 2003, 256 : 253 - 257
  • [28] Epithermal instrumental neutron activation analysis for the determination of gold and arsenic in Ghanaian gold tailings using conventional and anti-coincidence counting
    Nyarko, BJB
    Serfor-Armah, Y
    Holzbecher, J
    Osae, EK
    Akaho, EHK
    Carboo, D
    Chatt, A
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 256 (02) : 253 - 257
  • [29] Single- and multi-deadtime parameter corrections of one- and two-dimensional Rossi-alpha distributions for time interval analysis in neutron coincidence counting
    Baeten, P
    Bruggeman, M
    Carchon, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (03): : 345 - 358