Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

被引:5
|
作者
Croft, Stephen [1 ]
Burr, Tom [2 ]
Favalli, Andrea [3 ]
Nicholson, Andrew [1 ]
机构
[1] Oak Ridge Natl Lab, One Bethel Valley Rd, Oak Ridge, TN USA
[2] IAEA, A-1400 Vienna, Austria
[3] Los Alamos Natl Lab, MS E540, Los Alamos, NM 87545 USA
关键词
Neutron collar; Fresh LWR fuel assay; Linear regression; Errors in predictor; UNCERTAINTY;
D O I
10.1016/j.nima.2015.11.154
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The declared linear density of U-238 and U-235 in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of U-235 (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This paper compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. We find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters. Published by Elsevier B.V.
引用
收藏
页码:70 / 75
页数:6
相关论文
共 29 条
  • [1] First principle active neutron coincidence counting measurements of uranium oxide
    Goddard, Braden
    Charlton, William
    Peerani, Paolo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 739 : 1 - 5
  • [2] Technical Basis for the Use of a Correlated Neutron Source in the Uranium Neutron Coincidence Collar
    Root, M. A.
    Menlove, H. O.
    Lanza, R. C.
    Rael, C. D.
    Miller, K. A.
    Marlow, J. B.
    NUCLEAR TECHNOLOGY, 2017, 197 (02) : 180 - 190
  • [3] Calibration of an active well coincidence counter and a passive neutron coincidence collar for verification of fast breeder fresh fuel assemblies
    Czock, K.H.
    Fager, J.
    Saringer, G.
    Menlove, H.O.
    Mozhaev, V.
    Tuzov, A.
    Pshakin, G.
    JNMM, Journal of the Institute of Nuclear Materials Management, 26 (04): : 36 - 40
  • [4] Field testing of a fast-neutron coincidence collar for fresh uranium fuel verification
    Beaumont, Jonathan
    Lee, Taehoon
    Mayorov, Mikhail
    Jeon, Jong Kyu
    Bonino, Anibal
    Grund, Marcos
    Dutra, Marcos
    Renha, Geraldo
    Ahn, Seung Ho
    Kim, Ki Hyun
    Park, Jung Suk
    Yang, Gui Hyun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 962
  • [5] URANIUM AND PLUTONIUM ASSAY OF CREATED WASTE BY GAMMA RAY, SINGLES NEUTRON, AND SLOW NEUTRON COINCIDENCE COUNTING.
    Harlan, Ronald A.
    National Bureau of Standards, Special Publication, 1979, : 622 - 632
  • [6] Determination of multielements by neutron activation analysis using a coincidence counting method
    Suzuki, S
    Okada, Y
    Hirai, S
    BUNSEKI KAGAKU, 2000, 49 (11) : 875 - 880
  • [7] Distinguishing fissile uranium isotopes using an active well neutron coincidence counter
    Reed, Richard L.
    Evans, Louise G.
    McElroy Jr, Robert D.
    Lockhart, Madeline L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [8] MCNP-PoliMi Analysis of Neutron-Source Penetrability in Uranium-Oxide Samples Measured with an Active Well Coincidence Counter
    Clarke, S. D.
    Flaska, M.
    Pozzi, S. A.
    Oberer, R. B.
    Chiang, L. G.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 995 - 999
  • [9] Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay
    Broughton, D. P.
    Grund, M. S.
    Renha Jr, G.
    Croft, S.
    Favalli, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1001