Treatment of chronic type B aortic dissection with endovascular stent-graft placement

被引:14
|
作者
Kato, N [1 ]
Hirano, T [1 ]
Shimono, T [1 ]
Nomura, Y [1 ]
Goto, M [1 ]
Sakuma, H [1 ]
Yada, I [1 ]
Takeda, K [1 ]
机构
[1] Mie Univ Hosp, Dept Radiol, Tsu, Mie 514, Japan
关键词
aorta; dissection; stent graft; endovascular intervention;
D O I
10.1007/s002709910010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 74-year-old man with chronic aortic dissection was treated with an endovascular stent graft, fabricated from expanded polytetrafluoroethylene and a Z-stent. It was placed in the true lumen to close an entry tear. Closure was obtained immediately and thrombosis of the false lumen at the descending thoracic aorta was observed on computed tomography (CT) obtained 1 week later. No procedure-related complications developed. The patient is doing well with no adverse events including aortic rupture or aortic branch ischemia.
引用
收藏
页码:60 / 62
页数:3
相关论文
共 50 条
  • [1] Treatment of chronic type B aortic dissection with endovascular stent-graft placement
    Noriyuki Kato
    Tadanori Hirano
    Takatsugu Shimono
    Yoshiyuki Nomura
    Miwako Goto
    Hajime Sakuma
    Isao Yada
    Kan Takeda
    CardioVascular and Interventional Radiology, 2000, 23 : 60 - 62
  • [2] The comparison of separate stent-graft and conventional stent-graft for the endovascular treatment of chronic type B aortic dissection
    Shim, WH
    Park, SH
    Ko, YG
    Choi, DH
    Jang, YS
    Lee, DY
    Chang, BC
    EUROPEAN HEART JOURNAL, 2004, 25 : 215 - 215
  • [3] Endovascular Stent-graft Placement for Retrograde Type A Aortic Dissection
    Jiang, Jianjun
    Ding, Xiangjiu
    Zhang, Guangyong
    Hu, Sanyuan
    Su, Qingbo
    Li, Feng
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (03) : 415 - 417
  • [4] Endovascular Stent-graft Placement in Stanford Type B Aortic Dissection in China
    Chang, G. -Qi
    Li, Z. -Lun
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 37 (06) : 646 - 653
  • [5] Endovascular stent-graft placement for complications of acute type B aortic dissection
    Eggebrecht, H
    Lönn, L
    Herold, U
    Breuckmann, F
    Leyh, R
    Jakob, HG
    Erbel, R
    CURRENT OPINION IN CARDIOLOGY, 2005, 20 (06) : 477 - 483
  • [6] Endovascular stent-graft placement for the treatment of acute aortic dissection
    Dake, MD
    Kato, N
    Mitchell, RS
    Semba, CP
    Razavi, MK
    Shimono, T
    Hirano, T
    Takeda, K
    Yada, I
    Miller, DC
    NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20): : 1546 - 1552
  • [7] Comment on "Endovascular Stent-graft Placement in Stanford Type B Aortic Dissection in China"
    Xiong, J.
    Guo, W.
    Liu, X. P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (04) : 542 - 542
  • [8] Treatment of chronic aortic dissection by transluminal endovascular stent-graft placement: Preliminary results
    Kato, N
    Hirano, T
    Shimono, T
    Ishida, M
    Takano, K
    Nishide, Y
    Kawaguchi, T
    Yada, I
    Takeda, R
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (07) : 835 - 840
  • [9] Endovascular stent-graft placement in aortic dissection - a metaanalysis
    Eggebrecht, H.
    Nienaber, C. A.
    Neuhaeuser, M.
    Kische, S.
    Schmermund, A.
    Rehders, T.
    Jakob, H. G.
    Erbel, R.
    EUROPEAN HEART JOURNAL, 2005, 26 : 659 - 659
  • [10] Retrograde type A aortic dissections after endovascular stent-graft placement for type B dissection
    Bellos, J. K.
    Petrosyan, A.
    Abdulamit, T.
    Trastour, J. -C.
    Bergeron, P.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2010, 51 (01): : 85 - 93