Endovascular stent-graft placement for the treatment of acute aortic dissection

被引:943
|
作者
Dake, MD
Kato, N
Mitchell, RS
Semba, CP
Razavi, MK
Shimono, T
Hirano, T
Takeda, K
Yada, I
Miller, DC
机构
[1] Stanford Univ, Med Ctr, Sch Med, Div Cardiovasc & Intervent Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Dept Cardiovasc & Thorac Surg, Stanford, CA 94305 USA
[3] Mie Univ, Sch Med, Dept Radiol, Tsu, Mie 514, Japan
[4] Mie Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Tsu, Mie 514, Japan
来源
NEW ENGLAND JOURNAL OF MEDICINE | 1999年 / 340卷 / 20期
关键词
D O I
10.1056/NEJM199905203402004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The standard treatment for acute aortic dissection is either surgical or medical therapy, depending on the morphologic features of the lesion and any associated complications. Irrespective of the form of treatment, the associated mortality and morbidity are considerable. Methods We studied the placement of endovascular stent-grafts across the primary entry tear for the management of acute aortic dissection originating in the descending thoracic aorta. We evaluated the feasibility, safety, and effectiveness of transluminal stent-graft placement over the entry tear in 4 patients with acute type A aortic dissections (which involve the ascending aorta) and 15 patients with acute type B aortic dissections (which are confined to the descending aorta). Dissections involved aortic branches in 14 of the 19 patients (74 percent), and symptomatic compromise of multiple branch vessels was observed in 7 patients (37 percent). The stent-grafts were made of self-expanding stainless-steel covered with woven polyester or polytetrafluoroethylene material. Results Placement of endovascular stent-grafts across the primary entry tears was technically successful in all 19 patients. Complete thrombosis of the thoracic aortic false lumen was achieved in 15 patients (79 percent), and partial thrombosis was achieved in 4 (21 percent). Revascularization of ischemic branch vessels, with subsequent relief of corresponding symptoms, occurred in 76 percent of the obstructed branches. Three of the 19 patients died within 30 days, for an early mortality rate of 16 percent (95 percent confidence interval, 0 to 32 percent). There were no deaths and no instances of aneurysm or aortic rupture during the subsequent average follow-up period of 13 months. Conclusions These initial results suggest that stent-graft coverage of the primary entry tear may be a promising new treatment for selected patients with acute aortic dissection. This technique requires further evaluation, however, to assess its therapeutic potential fully. (N Engl J Med 1999;340:1546-52.) (C)1999, Massachusetts Medical Society.
引用
收藏
页码:1546 / 1552
页数:7
相关论文
共 50 条
  • [1] Endovascular stent-graft placement in aortic dissection - a metaanalysis
    Eggebrecht, H.
    Nienaber, C. A.
    Neuhaeuser, M.
    Kische, S.
    Schmermund, A.
    Rehders, T.
    Jakob, H. G.
    Erbel, R.
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 : 659 - 659
  • [2] Treatment of acute type A dissection by percutaneous endovascular stent-graft placement
    Zimpfer, Daniel
    Czerny, Martin
    Kettenbach, Joachim
    Schoder, Maria
    Wolner, Ernst
    Lammer, Johannes
    Grimm, Michael
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (02): : 747 - 749
  • [3] Endovascular stent-graft placement for complications of acute type B aortic dissection
    Eggebrecht, H
    Lönn, L
    Herold, U
    Breuckmann, F
    Leyh, R
    Jakob, HG
    Erbel, R
    [J]. CURRENT OPINION IN CARDIOLOGY, 2005, 20 (06) : 477 - 483
  • [4] Endovascular stent-graft placement to obliterate the entry tear: A new treatment for acute aortic dissection
    Dake, MD
    Kato, N
    Slonim, SM
    Razavi, MK
    Semba, CP
    Kee, ST
    Sze, DY
    Samuels, SL
    Mitchell, RS
    Miller, DC
    [J]. CIRCULATION, 1998, 98 (17) : 67 - 67
  • [5] Endovascular Stent-graft Placement for Retrograde Type A Aortic Dissection
    Jiang, Jianjun
    Ding, Xiangjiu
    Zhang, Guangyong
    Hu, Sanyuan
    Su, Qingbo
    Li, Feng
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (03) : 415 - 417
  • [6] Retrograde aortic dissection after endovascular stent-graft placement
    Prieto Cuadra, Juan Daniel
    Alvarez Mancha, Ana Isabel
    Lucena Romero, Joaquin
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2020, 73 (05):
  • [7] Treatment of chronic type B aortic dissection with endovascular stent-graft placement
    Noriyuki Kato
    Tadanori Hirano
    Takatsugu Shimono
    Yoshiyuki Nomura
    Miwako Goto
    Hajime Sakuma
    Isao Yada
    Kan Takeda
    [J]. CardioVascular and Interventional Radiology, 2000, 23 : 60 - 62
  • [8] Treatment of chronic type B aortic dissection with endovascular stent-graft placement
    Kato, N
    Hirano, T
    Shimono, T
    Nomura, Y
    Goto, M
    Sakuma, H
    Yada, I
    Takeda, K
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (01) : 60 - 62
  • [9] Endovascular stent-graft placement in aortic dissection:: a meta-analysis
    Eggebrecht, H
    Nienaber, CA
    Neuhäuser, M
    Baumgart, D
    Kische, S
    Schmermund, A
    Herold, U
    Rehders, TC
    Jakob, HG
    Erbel, R
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (04) : 489 - 498
  • [10] Treatment of chronic aortic dissection by transluminal endovascular stent-graft placement: Preliminary results
    Kato, N
    Hirano, T
    Shimono, T
    Ishida, M
    Takano, K
    Nishide, Y
    Kawaguchi, T
    Yada, I
    Takeda, R
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (07) : 835 - 840