Development of a Tongue Immobilization Device Using a 3D Printer for Intensity Modulated Radiation Therapy of Nasopharyngeal Cancer Patients

被引:6
|
作者
Ju, Sang Gyu [1 ]
Ahn, Yong Chan [1 ,2 ]
Kim, Yeong-bi [1 ]
Park, Seung Gyu [1 ]
Choi, Yoo-mi [1 ,2 ]
Na, Cho Hee [1 ,2 ]
Hong, Chae-Seon [3 ]
Oh, Dongryul [1 ]
Kwon, Dong Yeol [1 ]
Kim, Cheol Chong [1 ]
Kim, Dong Hyeon [4 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiat Oncol, 81 Irwon Ro, Seoul 06351, South Korea
[2] Sungkyunkwan Univ, Samsung Adv Inst Hlth Sci & Technol, Dept Med Device Management & Res, Seoul, South Korea
[3] Yonsei Univ, Coll Med, Yonsei Canc Ctr, Dept Radiat Oncol, Seoul, South Korea
[4] Kyungpook Natl Univ, Inst Adv Convergence Technol, Daegu, South Korea
来源
CANCER RESEARCH AND TREATMENT | 2021年 / 53卷 / 01期
关键词
Tongue immobilization device; 3D printing; Head and neck cancer; Tomotherapy; Radiation therapy; DOSE CALCULATION; LUNG-CANCER; NECK CANCER; CHEMO-IMRT; HEAD; RADIOTHERAPY; CHEMOTHERAPY; IRRADIATION; XEROSTOMIA; PREDICTORS;
D O I
10.4143/crt.2020.572
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose This study aimed to reduce radiation doses to the tongue, a patient-specific semi-customized tongue immobilization device (SCTID) was developed using a 3D printer for helical tomotherapy (HT) of nasopharyngeal cancer (NPCa). Dosimetric characteristics and setup stability of the SCT1D were compared with those of a standard mouthpiece (SMP). Materials and Methods For displacement and robust immobilization of the tongue, the SCTID consists of four parts: upper and lower tooth stoppers, tongue guider, tongue-tip position guide bar, and connectors. With the SCTID and SMP, two sets of planning computed tomography and HT plans were obtained for 10 NPCa patients. Dosimetric and geometric characteristics were compared. Position reproducibility of the tongue with SCT1D was evaluated by comparing with planned dose and adaptive accumulated dose of the tongue and base of the tongue based on daily setup mega-voltage computed tomography. Results Using the SCTID, the tongue was effectively displaced from the planning target volume compared to the SMR The median mucosa of the tongue (M-tongue) dose was significantly reduced (20.7 Gy vs. 27.8 Gy). The volumes of the M-tongue receiving a dose of 15 Gy, 30 Gy, and 45 Gy and the volumes of the mucosa of oral cavity and oropharynx (M-OC/OP) receiving a dose of 45 Gy and 60 Gy were significantly lower than using the SMR No significant differences was observed between the planned dose and the accumulated adaptive dose in any dosimetric characteristics of the tongue and base of tongue. Conclusion SCTID can not only reduce the dose to the M-tongue and M-OC/OP dramatically, when compared to SMP, but also provide excellent reproducibility and easy visual verification.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [1] Development of a customized tongue displacement device using a 3D printer in head and neck IMRT
    Hong, C. S.
    Ju, S. G.
    Oh, D.
    Ahn, Y. C.
    Na, C. H.
    Kwon, D. Y.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S516 - S517
  • [2] Intensity modulated radiation therapy in elderly patients with nasopharyngeal carcinoma
    Tianzhu Lu
    Xiaopeng Xiong
    Fangyan Zhong
    Xiaochang Gong
    Jingao Li
    Holistic Integrative Oncology, 2 (1):
  • [3] Development of a semi-customized tongue displacement device using a 3D printer for head and neck IMRT
    Chae-Seon Hong
    Dongryul Oh
    Sang Gyu Ju
    Yong Chan Ahn
    Cho Hee Na
    Dong Yeol Kwon
    Cheol Chong Kim
    Radiation Oncology, 14
  • [4] Development of a semi-customized tongue displacement device using a 3D printer for head and neck IMRT
    Hong, Chae-Seon
    Oh, Dongryul
    Ju, Sang Gyu
    Ahn, Yong Chan
    Na, Cho Hee
    Kwon, Dong Yeol
    Kim, Cheol Chong
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [5] Beam configurations for 3D tomographic intensity modulated radiation therapy
    Levine, RY
    Braunstein, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (05): : 765 - 787
  • [6] 3D treatment planning and intensity-modulated radiation therapy
    Purdy, JA
    ONCOLOGY-NEW YORK, 1999, 13 (10): : 155 - 168
  • [7] Comparative outcomes for 3D conformal versus intensity modulated radiation therapy for esophageal cancer
    Freilich, Jessica
    Chuong, Michael
    Yue, Binglin
    Fulp, William J.
    Abuodeh, Yazan Asad
    Almhanna, Khaldoun
    Meredith, Kenneth
    Karl, Richard C.
    Hoffe, Sarah
    Shridhar, Ravi
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (04)
  • [8] Comparison of 3D conformal radiation therapy and intensity-modulated radiation therapy in patients with endometrial cancer: efficacy, safety and prognostic analysis
    Minh-Hanh Ta
    Schernberg, Antoine
    Giraud, Paul
    Monnier, Laurie
    Darai, Emile
    Bendifallah, Sofiane
    Schlienger, Michel
    Touboul, Emmanuel
    Orthuon, Alexandre
    Challand, Thierry
    Huguet, Florence
    del Campo, Eleonor Rivin
    ACTA ONCOLOGICA, 2019, 58 (08) : 1127 - 1134
  • [9] Economical Evaluation of Cancer Types Using Intensity-Modulated Radiation Therapy Compared to 3D Conformal Radiation Therapy: A Systematic Review
    Alipour, Vahid
    Rezapour, Aziz
    Adel, Amin
    Pourtaleb, Arefeh
    Bazrafshan, Mitra
    Mohammadi, Mozhgan Sadat Ghaem
    Jahangiri, Reza
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2023, 52 (07) : 1355 - 1366
  • [10] Influence of intensity-modulated radiation therapy technique on xerostomia and related quality of life in patients treated with intensity-modulated radiation therapy for nasopharyngeal cancer
    Marucci, Laura
    Marzi, Simona
    Sperduti, Isabella
    Giovinazzo, Giuseppe
    Pinnaro, Paola
    Benassi, Marcello
    Strigari, Lidia
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2012, 34 (03): : 328 - 335