Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis

被引:0
|
作者
Sparacia, G [1 ]
Angileri, T [1 ]
Accardi, M [1 ]
Pappalardo, S [1 ]
Sarno, C [1 ]
DeMaria, M [1 ]
机构
[1] UNIV PALERMO,IST RADIOL P CIGNOLINI,I-90133 PALERMO,ITALY
来源
关键词
magnetic resonance imaging; spin-echo; fast spin-echo; brain; multiple sclerosis;
D O I
10.1177/19714009970100S2106
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We compared T2-weighted fast spin-echo (FSE) magnetic resonance (MR) imaging and conventional spin-echo (CSE) T2-weighted imaging in the detection of brain lesions of multiple sclerosis (MS). 20 patients with clinically definite MS underwent brain imaging with both FSE and CSE T2-weighted imaging. There was no significant difference in total number of lesions detected on FSE vs CSE (1354 vs 1378). Slightly more periventricular and subcortical lesions were detected using CSE than FSE, whereas more posterior cranial fossa lesions were detected by FSE. There was no statistically significant difference in the signal intensity (SI) ratio of MS lesions to that of surrounding normal white matter on FSE vs CSE, however the SI ratio of MS lesions was lower on FSE T2-weighted images (FSE = 1.87 +/- 0.39 vs CSE = 2.09 +/- 0.36). Considerable time savings can accrue when substituting FSE for CSE sequences in T2-weighted imaging, and this Is a compelling reason to employ such sequence in clinical practice. Our results suggest that although CSE sequences are required to confirm the diagnosis of brain involvement of MS lesions, T2-weighted FSE sequences can replace CSE sequences in long term monitoring especially when patient's movements preclude useful investigation and when optional scanning planes are required.
引用
收藏
页码:233 / 235
页数:3
相关论文
共 50 条
  • [31] T2-weighted spin-echo MR imaging of the liver: Breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression
    Soyer, P
    LeNormand, S
    deGivry, SC
    Gueye, C
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 593 - 597
  • [32] MR-IMAGING OF DISEASES OF THE BRAIN - COMPARISON OF CEASE AND CONVENTIONAL SPIN-ECHO T2-WEIGHTED PULSE SEQUENCES
    PATEL, MR
    KLUFAS, RA
    SHAPIRO, AW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 963 - 966
  • [33] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [34] A COMPARISON BETWEEN FAST AND CONVENTIONAL SPIN-ECHO IN THE DETECTION OF MULTIPLE-SCLEROSIS LESIONS
    THORPE, JW
    HALPIN, SF
    MACMANUS, DG
    BARKER, GJ
    KENDALL, BE
    MILLER, DH
    NEURORADIOLOGY, 1994, 36 (05) : 388 - 392
  • [35] T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
    Masui, T
    Katayama, M
    Kobayashi, S
    Sakahara, H
    Ito, T
    Nozaki, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 930 - 937
  • [36] REDUCTION OF MRT TIMING FOR EXAMINATION OF THE FEMALE PELVIS USING T2-WEIGHTED FAST SPIN-ECHO (FSE) TECHNIQUES - QUANTITATIVE AND QUALITATIVE COMPARISON OF CONVENTIONAL SPIN-ECHO (SE) AND FAST SPIN-ECHO (FSE)
    HALDEMANN, RC
    KRESTIN, GP
    DUEWELL, S
    MARINCEK, B
    VONSCHULTHESS, GK
    SAADIELMANDJRA, M
    FUCHS, WA
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (02): : 127 - 132
  • [37] Effect of Deep Learning Reconstruction on Respiratory-triggered T2-weighted MR Imaging of the Liver: A Comparison between the Single-shot Fast Spin-echo and Fast Spin-echo Sequences
    Kiso, Kengo
    Tsuboyama, Takahiro
    Onishi, Hiromitsu
    Ogawa, Kazuya
    Nakamoto, Atsushi
    Tatsumi, Mitsuaki
    Ota, Takashi
    Fukui, Hideyuki
    Yano, Keigo
    Honda, Toru
    Kakemoto, Shinji
    Koyama, Yoshihiro
    Tarewaki, Hiroyuki
    Tomiyama, Noriyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (02) : 214 - 224
  • [38] MR imaging of the rotator cuff mechanism: Comparison of spin-echo and turbo spin-echo sequences
    Sonin, AH
    Peduto, AJ
    Fitzgerald, SW
    Callahan, CM
    Bresler, ME
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 333 - 338
  • [39] Fat-suppressed T2-weighted MR imaging of the liver: Comparison of respiratory triggered fast spin-echo, breath-hold single-shot fast spin-echo and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Sakahara, H
    Nozaki, A
    RADIOLOGY, 2000, 217 : 587 - 587
  • [40] MR MYELOGRAPHY USING HEAVILY T2-WEIGHTED FAST SPIN-ECHO PULSE SEQUENCES WITH FAT PRESATURATION
    KRUDY, AG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (06) : 1315 - 1320