Proximal Interphalangeal Joint Silicone Arthroplasty - Comparison of Swanson and NeuFlex® Implants using a New Evaluation Score

被引:17
|
作者
Stahlenbrecher, A. [1 ]
Hoch, J. [1 ]
机构
[1] Klinikum Neustadt, Klin Hand Brust & Plast Chirurg, D-23730 Neustadt, Germany
关键词
proximal interphalangeal joint; PIPJ endoprosthesis; Swanson implant; NeuFlex (R) implant; score; HAND;
D O I
10.1055/s-0029-1220921
中图分类号
R61 [外科手术学];
学科分类号
摘要
Proximal interphalangeal joint arthroplasty with a silicone implant has proven to be successful in cases of degenerative, post-traumatic or rheumatic arthritis. The recent changing of the implant's design by introducing a 30-degree preflexion has replaced the common Swanson implant in some centres. Nevertheless, directly comparing follow-up studies between the two implant forms are still lacking as well as the use of a standard evaluation score for proximal interphalangeal joint arthroplasties. Between 1990 and 2007 a series of 67 proximal interphalangeal joint arthroplasties with a silicone device has been carried out in 54 patients. Among these a retrospective clinical and radiological investigation could be performed on 43 patients with 53 joints at 6-144, in the mean 34 months, after operation. 39 cases of degenerative, 12 cases of post-traumatic, I case of rheumatic arthritis and 1 post-traumatic arthrodesis were treated with 20 Swanson implants and 33 NeuFlex (R) implants. In 41 joints a mediolateral approach taking care of the extensor tendon's integrity was used, in 12 joints the extensor tendon was dissected longitudinally using a dorsal approach. At the time of investigation 5 implants had already been removed due to infection, implant fracture and painful extensive osteophytes. Comparing the remaining prostheses, 18 Swanson implants and 30 NeuFlex (R) implants, the latter showed a better average total range of motion, improving from 42.5 degrees preoperatively to 56 degrees postoperatively, in contrast to the Swanson implants with a deterioration from 50.8 degrees preoperatively to 47.2 degrees postoperatively. However, they were inferior to the classic Swanson implant as the joint's circumference was more enlarged by 1.8 mm in the mean and a geater finger length shortning of average 2.5 mm as well as a higher rate of stress pain and instability (15%) were evident. While the NeuFlex (R) implants led to a better subjective satisfaction, the Swanson implants gained better objective results using a new evaluation score (11% very good, 50% good, 28% satisfactory, 11% bad) than the NeuFlex (R) implants (50% good, 40% satisfactory, 10% bad). Remarkably the NeuFlex (R) devices showed an extremely high rate of early implant fractures after 8-31 months, in the mean 18 months, postoperatively, which was not seen with any of the Swanson implants - in spite of an average duration of 59.4 months.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 50 条
  • [11] Silicone Proximal Interphalangeal Joint Arthroplasty for Primary Osteoarthritis Using a Volar Approach
    Proubasta, Ignacio R.
    Lamas, Claudia G.
    Natera, Luis
    Millan, Angelica
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (06): : 1075 - 1081
  • [12] The dorsal approach to silicone implant arthroplasty of the proximal interphalangeal joint
    Bickel, Kyle D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (06): : 909 - 913
  • [13] Lateral shotgun approach for proximal interphalangeal joint silicone arthroplasty
    Tsumura, Takuya
    Matsumoto, Taiichi
    Ikeguchi, Ryosuke
    Kakinoki, Ryosuke
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (08) : 803 - 805
  • [14] An Outcomes Study of Proximal Interphalangeal Joint Silicone Implant Arthroplasty Using the Volar Approach
    Riggs, Jeanne M.
    Burns, Patricia B.
    Chung, Kevin C.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 150 (02) : 341 - 351
  • [15] Pyrocarbon versus Silicone Proximal Interphalangeal Joint Arthroplasty: A Systematic Review
    Chan, Kevin
    Ayeni, Olubimpe
    McKnight, Leslie
    Ignacy, Teegan A.
    Farrokhyar, Forough
    Thoma, Achilleas
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (01) : 114 - 124
  • [16] Proximal interphalangeal Joint Replacement : Resurfacing Pyrocarbon versus Silicone Arthroplasty
    Van Nuffel, Maarten
    Degreef, Ilse
    Willems, Sofie
    De Smet, Luc
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (02): : 190 - 195
  • [17] SILICONE REPLACEMENT ARTHROPLASTY IN POST TRAUMATIC DISABILITIES OF PROXIMAL INTERPHALANGEAL JOINT
    STRICKLAND, JW
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (05): : 1096 - 1096
  • [18] Long-term assessment of Swanson implant arthroplasty in the proximal interphalangeal joint of the hand
    Takigawa, S
    Meletiou, S
    Sauerbier, M
    Cooney, WP
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (05): : 785 - 795
  • [19] Factors Associated With Reoperation After Silicone Proximal Interphalangeal Joint Arthroplasty
    Lans, Jonathan
    Notermans, Bo J. W.
    Germawi, Lazin
    Lee, Hang
    Jupiter, Jesse B.
    Chen, Neal C.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (04): : 461 - 466
  • [20] Outcomes of Multiple Digit Proximal Interphalangeal Joint Swanson Arthroplasty Done at a Single Operation
    Hourston, George
    Begum, Rumina
    Sarker, Shahrier
    Chojnowski, Adrian
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2022, 27 (02): : 280 - 284