Assessing Four-dimensional Radiotherapy Planning and Respiratory Motion-induced Dose Difference Based on Biologically Effective Uniform Dose

被引:3
|
作者
Su, Fan-Chi [1 ,2 ]
Shi, Chengyu [1 ,2 ]
Mavroidis, Panayiotis [3 ,4 ,5 ]
Goytia, Virginia [6 ]
Crownover, Richard [1 ,2 ]
Rassiah-Szegedi, Prema [7 ]
Papanikolaou, Niko [1 ,2 ]
机构
[1] Canc Therapy & Res Ctr S Texas, Dept Radiat Oncol, San Antonio, TX 78284 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Div Radiol Sci, San Antonio, TX 78229 USA
[3] Karolinska Inst, Dept Med Radiat Phys, S-10401 Stockholm, Sweden
[4] Stockholm Univ, Stockholm, Sweden
[5] Larissa Univ Hosp, Dept Med Phys, Larisa, Greece
[6] Ctr Radiat Oncol, Brandon, FL 33511 USA
[7] Univ Utah, Dept Radiat Oncol, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Four-dimensional treatment planning; Biologically effective uniform dose; Treatment planning; Radiobiological objectives; Organ motion; RELATIVE SERIALITY MODEL; BREAST-CANCER; ORGAN MOTION; MULTILEAF COLLIMATOR; RADIATION-THERAPY; TARGET VOLUME; IRRADIATION; DELIVERY; IMRT; PROBABILITY;
D O I
10.1177/153303460900800303
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Four-dimensional (4D) radiotherapy is considered as a feasible and ideal solution to accommodate intra-fractional respiratory motion during conformal radiation therapy. With explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy, 4D treatment planning in principle provides better dose conformity. However, the clinical benefits of developing 4D treatment plans in terms of tumor control rate and normal tissue complication probability as compared to other treatment plans based on CT images of a fixed respiratory phase remains mostly unproven. The aim of our study is to comprehensively evaluate 4D treatment planning for nine lung tumor cases with both physical and biological measures using biologically effective uniform dose ((D) over bar) together with complication-free tumor control probability, P+. Based on the examined lung cancer patients and PTV margin applied, we found similar but not identical curves of DVH, and slightly different mean doses in tumor (up to 1.5%) and normal tissue in all cases when comparing 4D, P-0%, and P-50% plans. When it comes to biological evaluations, we did not observe definitively PTV size dependence in P+ among these nine lung cancer patients with various sizes of PTV. Moreover, it is not necessary that 4D plans would have better target coverage or higher P+ as compared to a fixed phase IMRT plan. However, on the contrary to significant deviations in P+ (up to 14.7%) observed if delivering the IMRT plan made at end-inhalation incorrectly at end-exhalation phase, we estimated the overall P+, P-B, and P-I for 4D composite plans that have accounted for intra-fractional respiratory motion.
引用
收藏
页码:187 / 199
页数:13
相关论文
共 50 条
  • [21] An analysis of respiratory induced kidney motion on four-dimensional computed tomography and its implications for stereotactic kidney radiotherapy
    Shankar Siva
    Daniel Pham
    Suki Gill
    Mathias Bressel
    Kim Dang
    Thomas Devereux
    Tomas Kron
    Farshad Foroudi
    Radiation Oncology, 8
  • [22] Bladder surface dose modeling in prostate cancer radiotherapy: An analysis of motion-induced variations and the cumulative dose across the treatment
    Lao, Yi
    Cao, Minsong
    Yang, Yingli
    Kishan, Amar U.
    Yang, Wensha
    Wang, Yalin
    Sheng, Ke
    MEDICAL PHYSICS, 2021, 48 (12) : 8024 - 8036
  • [23] An analysis of respiratory induced kidney motion on four-dimensional computed tomography and its implications for stereotactic kidney radiotherapy
    Siva, Shankar
    Pham, Daniel
    Gill, Suki
    Bressel, Mathias
    Dang, Kim
    Devereux, Thomas
    Kron, Tomas
    Foroudi, Farshad
    RADIATION ONCOLOGY, 2013, 8
  • [24] Treatment planning for heavy-ion radiotherapy:: calculation and optimization of biologically effective dose
    Krämer, M
    Scholz, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3319 - 3330
  • [25] Accuracy and sensitivity of four-dimensional dose calculation to systematic motion variability in stereotatic body radiotherapy (SBRT) for lung cancer
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Ng, Sherry C. Y.
    Tong, Anthony S. M.
    Tam, Eric K. W.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 303 - 317
  • [26] Evaluation of dose prediction error and optimization convergence error in four-dimensional inverse planning of robotic stereotactic lung radiotherapy
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Tong, Anthony
    Tam, Eric
    Ng, Sherry C. Y.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 182 - 195
  • [27] Adaptive Radiation Therapy with a Four-Dimensional Dose Calculation Algorithm That Optimizes Dose Distribution Considering Breathing Motion
    Ali, I.
    Alsbou, N.
    Algan, O.
    Ahmad, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3437 - 3438
  • [28] Four-dimensional dose evaluation using deformable image registration in radiotherapy for liver cancer
    Jung, Sang Hoon
    Yoon, Sang Min
    Park, Sung Ho
    Cho, Byungchul
    Park, Jae Won
    Jung, Jinhong
    Park, Jin-hong
    Kim, Jong Hoon
    Ahn, Seung Do
    MEDICAL PHYSICS, 2013, 40 (01)
  • [29] A four-dimensional dosimeter and quality assurance phantom to quantify respiratory motion effects on the dose delivery for adaptive radiation therapy
    Meyers, Taylor
    Alsbou, Nesreen
    Ahmad, Salahuddin
    Ali, Imad
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2025, 24
  • [30] Motion-weighted target volume and dose-volume histogram: A practical approximation of four-dimensional planning and evaluation
    Zhang, Geoffrey
    Feygelman, Vladimir
    Huang, Tzung-Chi
    Stevens, Craig
    Li, Weiqi
    Dilling, Thomas
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 (01) : 67 - 72