Experimental study of convective heat transfer from in-line cam shaped tube bank in crossflow

被引:63
|
作者
Lavasani, Arash Mirabdolah [1 ]
Bayat, Hamidreza [2 ]
Maarefdoost, Taher [2 ]
机构
[1] Islamic Azad Univ, Cent Tehran Branch, Dept Mech Engn, Tehran, Iran
[2] Islamic Azad Univ, Cent Tehran Branch, Young Researchers & Elite Club, Tehran, Iran
关键词
Experimental; Cam shaped; Tube bank; Heat transfer; Crossflow; FORCED-CONVECTION; ELLIPTIC TUBES; PRESSURE-DROP; EXCHANGER; PERFORMANCE; CYLINDERS; OPTIMIZATION; BUNDLES;
D O I
10.1016/j.applthermaleng.2013.12.078
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer from cam-shaped tube bank has been studied experimentally. Tubes were mounted in an in-line arrangement with two longitudinal pitch ratios 1.5 and 2. Reynolds number based on equivalent diameter varied in range of 27,000 <= Re-D <= 42,500. Drag coefficient and heat transfer from tubes in second row were obtained. Results show that drag coefficient and heat transfer of cam shaped tubes depend on position of tubes in tube bank. Tubes that located at first and second column have the maximum and minimum value of drag coefficient, respectively. In addition, Heat transfer from subsequent tubes is greater than tube in first column. Thermal hydraulic performance of cam shape tube is about 6 times greater than circular tube with same equivalent diameter. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 50 条
  • [31] Experimental study on forced convective flow and heat transfer in a concentric annular tube
    State Key Lab. of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    不详
    Huaxue Gongcheng, 2007, 6 (12-15):
  • [32] Experimental study for forced convective heat transfer with molten salts in a circular tube
    Liu, Bin
    Wu, Yu-Ting
    Ma, Chong-Fang
    Zhao, Yao-Hua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (10): : 1739 - 1742
  • [33] HEAT-TRANSFER AROUND TUBES IN IN-LINE TUBE BANKS
    AIBA, S
    TSUCHIDA, H
    OTA, T
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1982, 25 (204): : 919 - 926
  • [35] Finite Analytic Solution of Convective Heat Transfer for Tube Arrays in Crossflow: Part II-Heat Transfer Analysis
    Chen, Ching Jen
    Wung, Tzong-Shyan
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 641 - 648
  • [36] EXPERIMENTAL INVESTIGATION ON HEAT TRANSFER AND PRESSURE DROP CHARACTERISTICS OF AIR FLOW OVER A STAGGERED FLAT TUBE BANK IN CROSSFLOW
    Ishak, M.
    Tahseen, Tahseen Ahmad
    Rahman, Md Mustafizur
    INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2013, 7 : 900 - 911
  • [37] Convective heat transfer in plane channels with in-line mounted rectangular bars
    Valencia, A
    Calderón, W
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2004, 14 (07) : 866 - 878
  • [38] Experimental investigation of in-line tube bundle heat transfer process to vertical downward foam flow
    Gylys, J.
    Zdankus, T.
    Jonynas, R.
    Maladauskas, R.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (11-12) : 2326 - 2333
  • [39] Numerical Investigations of the Convective Heat Transfer from Turbulent Flow Over Staggered Tube Bank
    Refaey H.A.
    Sultan A.M.
    Moawad M.
    Abdelrahman M.A.
    Journal of The Institution of Engineers (India): Series C, 2019, 100 (06): : 983 - 993
  • [40] Heat transfer at in-line tube bank under low-frequency asymmetrical impulses impact on fluid flow
    Khaibullina, Aigul
    Khairullin, Aidar
    Sinyavin, Alexey
    Ilin, Vladimir
    THERMOPHYSICAL BASIS OF ENERGY TECHNOLOGIES, 2014, 76