Experimental Testing and Numerical Simulation of a Six-Story Structure Incorporating Two-Degree-of-Freedom Nonlinear Energy Sink

被引:74
|
作者
Wierschem, Nicholas E. [1 ]
Luo, Jie [1 ]
AL-Shudeifat, Mohammad [2 ,3 ]
Hubbard, Sean [4 ]
Ott, Richard [5 ]
Fahnestock, Larry A. [1 ]
Quinn, D. Dane [5 ]
McFarland, D. Michael [4 ]
Spencer, B. F., Jr. [1 ]
Vakakis, Alexander [3 ]
Bergman, Lawrence A. [4 ]
机构
[1] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[2] Khalifa Univ Sci Technol & Res, Dept Aerosp Engn, Abu Dhabi, U Arab Emirates
[3] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61801 USA
[4] Univ Illinois, Dept Aerosp Engn, Urbana, IL 61801 USA
[5] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
关键词
Multi-story buildings; Simulation; Nonlinear systems; Damping; Passive control; Impulsive loads; Dynamic tests; Targeted energy transfer; Nonlinear energy sink; Shock mitigation; Shock and vibratory effects; COUPLED OSCILLATORS; RESONANCE CAPTURES; TRANSFERS; EFFICIENCY; ATTACHMENT; MITIGATION; SYSTEMS;
D O I
10.1061/(ASCE)ST.1943-541X.0000978
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The nonlinear energy sink (NES) is a fully passive attachment used to rapidly dissipate a significant portion of energy induced in a linear primary structure to which it is attached. In this study, the performance of a Type III NES in reducing the response of a large primary structure when subjected to a shock-type loading is evaluated experimentally. The Type III NES is a two-degree-of-freedom device comprising two relatively lightweight masses in series coupled together and to the primary structure through essentially nonlinear (i.e.,nonlinearizable) stiffness elements. The essential stiffness nonlinearity of the NES and the corresponding lack of preferential resonance frequencies enable it to resonantly interact with multiple structural modes over broad frequency and energy ranges. Hence a local NES can induce global effects in the dynamics of the structure to which it is attached. In this study, and for the first time, specially shaped polyurethane bumpers are employed for realizing these essentially nonlinear stiffness elements of the Type III NES. Measures calculated from the experiments in this study, such as the effective damping of the primary structure, indicate the ability of the NES to dissipate energy and reduce the response of the primary structure over a wide range of magnitudes of a shock loading. Good agreement between numerical predictions and experimental observations validates the identified model of the NES.
引用
收藏
页数:10
相关论文
共 43 条
  • [41] Vortex-Induced Vibrations of Two Degrees-of-Freedom Sprung Cylinder With a Rotational Nonlinear Energy Sink: A Numerical Investigation
    Chen, Dongyang
    Gu, Chaojie
    Zhang, Ruihua
    Liu, Jiaying
    Guo, Dian
    Marzocca, Pier
    JOURNAL OF COMPUTATIONAL AND NONLINEAR DYNAMICS, 2021, 16 (07):
  • [42] Study on Cubic Stiffness Nonlinear Energy Sink Controlling Dynamic Responses of Multi-Degree-of-Freedom Structure by Shake Table Tests
    Wang, Qinhua
    Yi, Xueshuang
    Yang, Dongxu
    Tang, Yi
    BUILDINGS, 2024, 14 (11)
  • [43] EXPERIMENTAL BLAST TESTING OF A LARGE 9-STORY STRUCTURE EQUIPPED WITH A SYSTEM OF NONLINEAR ENERGY SINKS
    Wierschem, Nicholas E.
    Hubbard, Sean A.
    Luo, Jie
    Fahnestock, Larry A.
    Spencer, B. F., Jr.
    Quinn, D. Dane
    McFarland, D. Michael
    Vakakis, Alexander F.
    Bergman, Lawrence A.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2013, VOL 8, 2014,