摘要
Benefits of pulsatile machine perfusion (pumping) of standard criteria donor (SCD) kidneys are unclear. Our center is located 41/2 hours from our Organ Procurement Organization. We evaluated outcomes of pumping SCD kidneys under such circumstances by conducting a retrospective examination of all SCD kidneys transplanted between January 2007 and March 2012, comparing kidneys pumped (28 [group 1]) versus standard cold storage (77 [group 2]). Group 1 had fewer delayed graft function (DGF, 3.57% vs. 23.38%, p = 0.02) and slow graft function (SGF, 7.14% vs. 24.68%; p = 0.047) and faster serum creatinine recovery curve (p < 0.001) than group 2. Having a kidney pumped decreases the incidence (odds ratio [OR], 0.059) of DGF, SGF, or primary nonfunction. Group 1 were quicker to reach an estimated glomerular filtration rate (eGFR) >30 ml/min (OR, 4.186; confidence interval [CI], [2.448-7.157]) or an eGFR >60 ml/min (OR, 2.669; CI [1.255-5.679]). Pumping the SCD kidneys in a geographically remote transplant center tended to be better than those preserved in cold storage. However, except recovery curve of serum creatinine during the first postoperative month, other parameters failed to reach statistical significance in the post hoc examination of the contemporary groups. Prospective paired kidney study is required to scrutinize this finding.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [21] Determinants of discard of expanded criteria donor kidneys: Impact of biopsy and pulsatile perfusion.
    Sung, RS
    Christensen, LL
    Leichtman, AB
    Greenstein, SM
    Distant, DA
    Wynn, JJ
    Stegall, MD
    Delmonico, FL
    Port, FK
    AMERICAN JOURNAL OF TRANSPLANTATION, 2005, 5 : 394 - 394
  • [22] The Prognostic Value of Renal Resistance During Hypothermic Machine Perfusion of Deceased Donor Kidneys
    Jochmans, I.
    Moers, C.
    Smits, J. M.
    Leuvenink, H. G. D.
    Treckmann, J.
    Paul, A.
    Rahmel, A.
    Squifflet, J-P
    van Heurn, E.
    Monbaliu, D.
    Ploeg, R. J.
    Pirenne, J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2011, 11 (10) : 2214 - 2220
  • [23] Does Keeping Deceased Donor Kidneys on Machine Perfusion for Longer Time Really Help?
    Algeizawi, Samer
    Farney, Alan
    Rogers, Jeffrey
    Stratta, Robert
    AMERICAN JOURNAL OF TRANSPLANTATION, 2011, 11 : 69 - 69
  • [24] The Benefits of Hypothermic Machine Preservation and Short Cold Ischemia Times in Deceased Donor Kidneys
    Kox, Jasper
    Moers, Cyril
    Monbaliu, Diethard
    Strelniece, Agita
    Treckmann, Juergen
    Jochmans, Ina
    Leuvenink, Henri
    Van Heurn, Ernest
    Pirenne, Jacques
    Paul, Andreas
    Ploeg, Rutger
    TRANSPLANTATION, 2018, 102 (08) : 1344 - 1350
  • [25] Hypothermic Machine Preservation Benefits Deceased Donor Kidneys With Short Cold Ischemic Times
    Hosgood, Sarah A.
    TRANSPLANTATION, 2018, 102 (08) : 1205 - 1206
  • [26] Preliminary Experience with Universal Use of Pulsatile Perfusion for Deceased Donor Kidneys: An Improvement in Early Graft Function.
    Hassanain, Mazen
    Tchervenkov, Jean
    Arena, Goffredo
    Metrakos, Peter
    Chaudhury, Prosanto
    Cantarovich, Marcelo
    Fernandez, Myriam
    Paraskevas, Steven
    AMERICAN JOURNAL OF TRANSPLANTATION, 2009, 9 : 582 - 582
  • [27] Graft Arteriosclerosis and Glomerulosclerosis Correlate with Initial Resistance to Pulsatile Pump Perfusion in Evaluation of Deceased Donor Kidneys for Transplantation
    Patel, S. K.
    Pankewycz, O.
    Weber-Shrikant, E.
    Alnimri, M.
    Said, M.
    Feng, L.
    Laftavi, M.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2011, 11 : 454 - 454
  • [28] 'When good kidneys pump badly': outcomes of deceased donor renal allografts with poor pulsatile perfusion characteristics
    Guarrera, James V.
    Goldstein, Michael J.
    Samstein, Benjamin
    Henry, Scot
    Reverte, Christopher
    Arrington, Ben
    Brown, Tod
    Coleman, Theresa K.
    Mattei, Gabriel
    Mendez, Natasha
    Kelly, Joan
    Ratner, Lloyd E.
    TRANSPLANT INTERNATIONAL, 2010, 23 (04) : 444 - 446
  • [29] DOES THE COST OF CONTINUOUS PULSATILE PERFUSION PRECLUDE ITS BENEFIT? THE UNMHSC EXPERIENCE WITH CONTINUOUS PULSATILE PERFUSION VERSUS STATIC COLD STORAGE OF DECEASED DONOR KIDNEYS
    Kerr, Hannah
    Davis, Michael
    Menotti, D. Mark
    Liu, Albert
    Paine, Susan
    Harford, Antonia
    JOURNAL OF UROLOGY, 2011, 185 (04): : E880 - E880
  • [30] NANOPARTICLE RELEASE BY EXTENDED CRITERIA DONOR KIDNEYS DURING NORMOTHERMIC MACHINE PERFUSION
    Woud, Wouter
    Merino, Ana
    Hoogduijn, Martin
    Boer, Karin
    van den Hoogen, Martijn
    Baan, Carla
    Minnee, Robert
    TRANSPLANT INTERNATIONAL, 2019, 32 : 360 - 360