Spectra-resolved technique of a sensitive time-resolved fluorescence immunoassay instrument

被引:0
|
作者
Guo, ZY [1 ]
Tian, Z [1 ]
Jia, YL [1 ]
机构
[1] S China Normal Univ, Inst Laser Life Sci, Guangzhou 510631, Peoples R China
关键词
spectra-resolved technology; time-resolved fluorescence; immunoassay; lanthanide;
D O I
10.1117/12.572442
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The lanthanide trivalence ion and its chelates are used for marking substance in time-resolved fluorescence immunoassay (TRFIA), marking the protein, hormone, antibody, nucleic acid probe or biologic alive cell, to measure the concentration of the analysis substance inside the reaction system with time-resolved fluorometry after the reaction system occurred, and attain the quantitative analysis's purpose. TRFIA has been become a kind of new and more sensitive measure method after radioisotope marking, enzymatic marking, chemiluminescence, electrochemiluminescence, it primarily is decided by the special physics and chemistry characteristic of lanthanide trivalence ion and its chelates. In this paper, the result of spectroscopic evaluation of europium trivalence ion and its chelate, and the principle of spectra-resolved technology and a sensitive time-resolved fluorescence immunoassay instrument made by ourselves are reported. In the set, a high frequency Xenon pulsed-light was adopted as exciting light, and two special filters was utilized according to spectra-resolved technique. Thus the influence of scattering light and short-lifetime fluorescence was removed. And the sensitivity is 10(-12)mol/L (when Eu3+ was used for marking substance), examination repeat is CVless than or equal to5 %, examination linearity is from 10 (-8) mol/L to 10(-12)mol/L, correlation coefficient rgreater than or equal to95%(p<0.01).
引用
收藏
页码:222 / 226
页数:5
相关论文
共 50 条
  • [21] Time-resolved fluorescence spectra of arterial fluorescent compounds: Reconstruction with the laguerre expansion technique
    Maarek, JMI
    Marcu, L
    Snyder, WJ
    Grundfest, WS
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2000, 71 (02) : 178 - 187
  • [22] IMMUNOASSAY BY TIME-RESOLVED ELECTROGENERATED LUMINESCENCE
    KANKARE, J
    HAAPAKKA, K
    KULMALA, S
    NANTO, V
    ESKOLA, J
    TAKALO, H
    ANALYTICA CHIMICA ACTA, 1992, 266 (02) : 205 - 212
  • [23] TIME-RESOLVED FLUORESCENCE IMMUNOASSAY SYSTEM ESPECIALLY SUITED FOR RESEARCH APPLICATIONS
    DIAMANDIS, EP
    CLINICAL CHEMISTRY, 1989, 35 (03) : 491 - 491
  • [24] An ELISA-like time-resolved fluorescence immunoassay for microcystin detection
    Lei, LM
    Wu, YS
    Gan, NQ
    Song, LR
    CLINICA CHIMICA ACTA, 2004, 348 (1-2) : 177 - 180
  • [25] A TIME-RESOLVED FLUORESCENCE IMMUNOASSAY FOR DIGOXIN USING A MONOCLONAL-ANTIBODY
    SHAMI, Y
    REICHSTEIN, E
    RAMJEESINGH, M
    VANGULCK, K
    ZYWULKO, M
    CLINICAL CHEMISTRY, 1986, 32 (06) : 1072 - 1073
  • [26] Determination of parvovirus antigen in the vaccine using time-resolved fluorescence immunoassay
    Chen, Cuicui
    Liang, Huankun
    Hu, Baoyu
    Ning, Bo
    Lai, Hongrui
    He, Ying
    Guo, Guiling
    Zhong, Shuhai
    Li, Laiqing
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2021, 68 (03) : 597 - 602
  • [27] IMMUNOASSAY OF NEONATAL HTSH IN PAPER DISKS USING TIME-RESOLVED FLUORESCENCE
    REICHSTEIN, E
    DIAMANDIS, EP
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1139 - 1139
  • [28] SOLID-PHASE IMMUNOASSAY OF DIGOXIN BY MEASURING TIME-RESOLVED FLUORESCENCE
    HELSINGIUS, P
    HEMMILA, I
    LOVGREN, T
    CLINICAL CHEMISTRY, 1986, 32 (09) : 1767 - 1769
  • [29] Rapid Homogenous Time-Resolved Fluorescence (HTRF) Immunoassay for Anthrax Detection
    Cohen, Noam
    Mechaly, Adva
    Mazor, Ohad
    Fisher, Morly
    Zahavy, Eran
    JOURNAL OF FLUORESCENCE, 2014, 24 (03) : 795 - 801
  • [30] Rapid Homogenous Time-Resolved Fluorescence (HTRF) Immunoassay for Anthrax Detection
    Noam Cohen
    Adva Mechaly
    Ohad Mazor
    Morly Fisher
    Eran Zahavy
    Journal of Fluorescence, 2014, 24 : 795 - 801