Beam test results for a tungsten-cerium fluoride sampling calorimeter with wavelength-shifting fiber readout

被引:5
|
作者
Becker, R. [1 ]
Candelise, V. [7 ,8 ]
Cavallari, F. [4 ]
Dafinei, I. [4 ]
Della Ricca, G. [7 ,8 ]
Diemoz, M. [4 ]
del Re, D. [4 ,5 ]
D'Imperio, G. [4 ,5 ]
Dissertori, G. [1 ]
Donega, M. [1 ]
Droege, M. [1 ]
Gelli, S. [4 ,5 ]
Haller, C. [1 ]
Lope, C. Jorda [4 ]
Lustermann, W. [1 ]
Martelli, A. [2 ,3 ]
Meridiani, P.
Micheli, F. [4 ,5 ]
Nessi-Tedaldi, F. [1 ]
Nuccetelli, M. [4 ]
Organtini, G. [4 ,5 ]
Quittnat, M. [1 ]
Pandolfi, F. [1 ]
Paramatti, R. [4 ]
Pastrone, N. [6 ]
Pellegrino, F. [4 ]
Peruzzi, M. [1 ]
Rahatlou, S. [4 ,5 ]
Rovelli, C. [4 ]
Santanastasio, F. [4 ,5 ]
Schoenenberger, M. [1 ]
Soffi, L. [4 ,5 ]
de Fatis, T. Tabarelli [2 ,3 ]
Vazzoler, F. [7 ,8 ]
机构
[1] ETH, Inst Particle Phys, Zurich, Switzerland
[2] Univ Milano Bicocca, Dipartimento Fis, Milan, Italy
[3] Ist Nazl Fis Nucl, Sez Milano Bicocca, I-20133 Milan, Italy
[4] Ist Nazl Fis Nucl, Sez Roma, I-20133 Milan, Italy
[5] Univ Roma La Sapienza, Dipartimento Fis, I-00185 Rome, Italy
[6] Ist Nazl Fis Nucl, Sez Torino, I-10125 Turin, Italy
[7] Univ Trieste, Trieste, Italy
[8] Ist Nazl Fis Nucl, Sez Trieste, Trieste, Italy
来源
基金
瑞士国家科学基金会;
关键词
Scintillators and scintillating fibres and light guides; Calorimeters;
D O I
10.1088/1748-0221/10/07/P07002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A sampling calorimeter using cerium fluoride scintillating crystals as active material, interleaved with heavy absorber plates, and read out by wavelength-shifting (WLS) fibers is being studied as a calorimeter option for detectors at the upgraded High-Luminosity LHC (HL-LHC) collider at CERN. A prototype has been exposed to electron beams of different energies at the INFN Frascati (Italy) Beam Test Facility. This paper presents results from the studies performed on the prototype, such as signal amplitudes, light yield and energy resolution.
引用
收藏
页数:11
相关论文
共 24 条
  • [21] Beam test results from a fine-sampling quartz fiber calorimeter for electron, photon and hadron detection
    Univ of Iowa, Iowa City, United States
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 399 (2-3): : 202 - 226
  • [22] Diagnosis of Neutron Sensitivity within a Scintillator/Wavelength-Shifting Fiber Coil Element by Using a Collimated Pulsed Neutron Beam
    Nakamura, T.
    Toh, K.
    Tsutsui, N.
    Ebine, M.
    Birumachi, A.
    Sakasai, K.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [23] Beam test results of a high-granularity tile/fiber electromagnetic calorimeter
    Ono, H.
    Miyata, H.
    Iba, S.
    Nakajima, N.
    Sanchez, A. L. C.
    Fujii, Y.
    Itoh, S.
    Kajino, F.
    Kanzaki, J.
    Kawagoe, K.
    Kim, S.
    Kishimoto, S.
    Matsumoto, T.
    Matsunaga, H.
    Nagano, A.
    Nakamura, R.
    Takeshita, T.
    Tamura, Y.
    Yamauchi, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (02): : 398 - 407
  • [24] THE CALICE TILE HADRON CALORIMETER PROTOTYPE WITH SIPM READOUT: DESIGN, CONSTRUCTION AND FIRST TEST BEAM RESULTS
    Wattimena, N.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 381 - 385