Determination of melamine impurities by capillary zone electrophoresis with UVand quadrupole time-of-flight mass spectrometric detection

被引:9
|
作者
Himmelsbach, Markus [1 ]
Thuy Diep Thanh Vo [2 ]
机构
[1] Johannes Kepler Univ Linz, Inst Analyt Chem, A-4040 Linz, Austria
[2] Borealis Polyolefine GmbH, Linz, Austria
关键词
CZE; Melamine; Melamine impurities; quadrupole TOF MS; ELECTROSPRAY-IONIZATION; LIQUID-CHROMATOGRAPHY; ION-TRAP; RESINS; MILK; MS;
D O I
10.1002/elps.201300493
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method based on CZE coupled to quadrupole TOF MS (Q-TOF MS), which is suitable to analyze seven common melamine impurities is presented. MS compatible formic acid based BGEs with various concentrations of organic modifiers were investigated using UV detection to determine the best separation system regarding resolution and speed. The optimized BGE consisted of 350 mM formic acid with 10% ACN and migration times were <6 min. The detection limits were considerably improved when ESI MS was applied instead of UV detection. In addition the instrument allows quantification with good linearity and repeatability in the relevant concentration range. The analytical characteristics of the method were evaluated for melamine, guanylurea, diaminotriazine, ureidomelamine, guanlymelamine, melam, methylmelamine, and dimethylmelamine both with UV and MS detection. Several different melamine samples were analyzed und the determined impurity levels were in the range from 0.02 to 2.3%.
引用
收藏
页码:1362 / 1367
页数:6
相关论文
共 50 条
  • [21] Analysis of Major Chemical Constituents in Jiuwei Decoction Based On Capillary Electrophoresis Coupled With Quadrupole Time-of-Flight Mass Spectrometry
    Zhao, Jiayu
    Li, Jinhong
    Xue, Hongyu
    Ma, Qiang
    ELECTROPHORESIS, 2024, : 322 - 330
  • [22] Multiple injection technique for the determination and quantitation of insulin formulations by capillary electrophoresis and time-of-flight mass spectrometry
    Staub, Aline
    Rudaz, Serge
    Veuthey, Jean-Luc
    Schappler, Julie
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (51) : 8041 - 8047
  • [23] Applicability of Liquid Chromatography with Time-of-Flight Mass Spectrometric Detection for Determination of Cyanuric Acid in Soil
    Stipicevic, Sanja
    Mendas, Gordana
    Vuletic, Marko
    Fingler, Sanja
    Drevenkar, Vlasta
    CROATICA CHEMICA ACTA, 2013, 86 (01) : 95 - 102
  • [24] Laser ablation of a silicon carbide target: a time-of-flight quadrupole mass spectrometric study
    S.H. Nam
    S.M. Park
    Applied Physics A, 2004, 79 : 1117 - 1120
  • [25] Laser ablation of a silicon carbide target: a time-of-flight quadrupole mass spectrometric study
    Nam, SH
    Park, SM
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2004, 79 (4-6): : 1117 - 1120
  • [26] Determination of phosphatidylcholine monohydroperoxides using quadrupole time-of-flight mass spectrometry
    Adachi, J
    Yoshioka, N
    Funae, R
    Nushida, H
    Asano, M
    Ueno, Y
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 806 (01): : 41 - 46
  • [27] Determination of ciprofloxacin and its impurities by capillary zone electrophoresis
    Michalska, K
    Pajchel, G
    Tyski, S
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) : 267 - 272
  • [28] Determination of rotenone in river water utilizing packed capillary column switching liquid chromatography with UV and time-of-flight mass spectrometric detection
    Holm, A
    Molander, P
    Lundanes, E
    Greibrokk, T
    JOURNAL OF CHROMATOGRAPHY A, 2003, 983 (1-2) : 43 - 50
  • [29] Laser vaporization/ionization interface for capillary electrophoresis time-of-flight mass spectrometry
    Chang, SY
    Yeung, ES
    ANALYTICAL CHEMISTRY, 1997, 69 (13) : 2251 - 2257
  • [30] Evaluation of time-of-flight mass spectrometric detection for fast gas chromatography
    van Deursen, MM
    Beens, J
    Janssen, HG
    Leclercq, PA
    Cramers, CA
    JOURNAL OF CHROMATOGRAPHY A, 2000, 878 (02) : 205 - 213