Failure of a cemented all-polyethylene patellar component of a Press-Fit Condylar total knee arthroplasty

被引:16
|
作者
Francke, EI [1 ]
Lachiewicz, PF [1 ]
机构
[1] Univ N Carolina, Dept Orthopaed, Chapel Hill, NC 27599 USA
来源
JOURNAL OF ARTHROPLASTY | 2000年 / 15卷 / 02期
关键词
Press-Fit Condylar modular total knee; all-polyethylene patella;
D O I
10.1016/S0883-5403(00)90396-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A 65-year-old woman had a posterior cruciate-retaining cemented Press-Fit Condylar (PFC; Johnson & Johnson Professional, Inc., Raynham, MA) knee replacement with resurfacing of the patella using a cemented all-polyethylene, 3-peg component. Five years postoperatively, the patient developed anterior knee pain. The patella tracked normally, but radiographs showed a shift of the patellar component. At revision, there was shear failure of all 3 fixation pegs and loosening of the component. Revision with a cemented Press-Fit Condylar Sigma patellar 3-pegs component (Johnson & Johnson Professional, Inc., Raynham, MA) was performed.
引用
收藏
页码:234 / 237
页数:4
相关论文
共 50 条
  • [21] All-polyethylene Tibial Components in Modern Total Knee Arthroplasty
    Browne, James A.
    Sims, Susan E. Gall
    Giuseffi, Steven A.
    Trousdale, Robert T.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (09) : 527 - 535
  • [22] No reduced patellar loading with latest-generation cruciate-retaining total knee arthroplasty-a comparative study of Attune and Press-Fit Condylar®
    Schiapparelli, Filippo-Franco
    Ahmadi, Puja
    Amsler, Felix
    Hirschmann, Michael T.
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (05) : 1205 - 1213
  • [23] Excellent Survival and Good Outcomes at 15 Years Using the Press-Fit Condylar Sigma Total Knee Arthroplasty
    Oliver, William M.
    Arthur, Calum H. C.
    Wood, Alexander M.
    Clayton, Robert A. E.
    Brenkel, Ivan J.
    Walmsley, Philip
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2524 - 2529
  • [24] Press-Fit Condylar design total knee arthroplasty - Fourteen to seventeen-year follow-up
    Rodricks, David J.
    Patil, Shantanu
    Pulido, Pamela
    Colwell, Clifford W., Jr.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (01): : 89 - 95
  • [25] Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty
    van Hamersveld, Koen T.
    Marang-Van de Mheen, Perla J.
    Nelissen, Rob G. H. H.
    Toksvig-Larsen, Soren
    ACTA ORTHOPAEDICA, 2018, 89 (04) : 412 - 417
  • [26] Short-term survival analysis of the all-polyethylene tibial component in total knee arthroplasty
    沈彬
    杨静
    裴福兴
    中华创伤杂志(英文版), 2005, (02) : 63 - 65
  • [27] Short-term survival analysis of the all-polyethylene tibial component in total knee arthroplasty
    沈彬
    杨静
    裴福兴
    ChineseJournalofTraumatology, 2005, (02)
  • [28] PATELLAR COMPONENT FAILURE IN CEMENTLESS TOTAL KNEE ARTHROPLASTY
    ROSENBERG, AG
    ANDRIACCHI, TP
    BARDEN, R
    GALANTE, JO
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (236) : 106 - 114
  • [29] Value comparison of humeral component press-fit and cemented techniques in reverse shoulder arthroplasty
    Berglund, Derek D.
    Mijic, Dragomir
    Law, Tsun Yee
    Kurowicki, Jennifer
    Rosas, Samuel
    Levy, Jonathan C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (03) : 496 - 502
  • [30] Press-Fit Condylar total knee arthroplasty - 5- to 9-year follow-up evaluation
    Martin, SD
    McManus, JL
    Scott, RD
    Thornhill, TS
    JOURNAL OF ARTHROPLASTY, 1997, 12 (06): : 603 - 614