A Randomized Crossover Study to Assess the Usability of Two New Vision Tests in Patients with Low Vision

被引:4
|
作者
Jolly, Jasleen K. [1 ,2 ]
Gray, Joanna M. [2 ]
Salvetti, Anna Paola [1 ,2 ]
Han, Ruofan C. [1 ,2 ]
MacLaren, Robert E. [1 ,2 ]
机构
[1] Univ Oxford, Nuffield Dept Clin Neurosci, Nuffield Lab Ophthalmol, Oxford, England
[2] John Radcliffe Hosp, Oxford Eye Hosp, Oxford Biomed Res Ctr, Oxford, England
关键词
FREIBURG VISUAL-ACUITY; PERFORMANCE; VARIABILITY; RELIABILITY; MOTION; CHARTS; PAPER;
D O I
10.1097/OPX.0000000000001380
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE Well-established charts such as Early Treatment Diabetic Retinopathy Study are able to quantify visual acuity (VA) with a low cutoff of 1.6 logMAR. Below this point, nonquantitative measures, such as count fingers, hand movements, and light perception, are used. There is a need for more reproducible, comparable, and reliable ways to measure VA changes in this patient cohort. PURPOSE The purpose of this study was to examine and compare the ability of the Berkeley Rudimentary Vision Test (BRVT) and the Freiburg Acuity Test (FrACT) to quantify VA in low-vision patients who score nonnumerical VAs in standard charts. METHODS Fifty adult participants with VA <= 1.0 logMAR in both eyes were recruited from the Oxford Eye Hospital, Oxford, United Kingdom. Correlation between FrACT and BRVT results and the correlation between VA and daily living activities were analyzed statistically. Potential predictors of differences were investigated. RESULTS The BRVT was significantly faster to conduct (P = .002), but FrACT was able to quantify vision numerically in a greater proportion of eyes. The kappa agreement between tests was 0.26. The difference increased systematically with the VA reduction (P < .0001). The Bland-Altman analysis showed a skew to measurement of lower logMAR VA indicating better vision measured on the FrACT. The only significant predictor of difference between the tests was binocular VA (coefficient, -0.445; P = .001). CONCLUSIONS Both tests are suitable for a very low-vision population. The BRVT is a faster test to administer, but FrACT provides a numerical result in more eyes. The poor intertest repeatability indicates that they cannot be used interchangeably. The BRVT generally reported poorer vision than did the FrACT. The medium of presentation, such as a computer screen or externally lit print medium, is likely to be the biggest factor in these differences and warrants further investigation.
引用
收藏
页码:443 / 452
页数:10
相关论文
共 50 条
  • [41] Detection of Depression in Patients with Low Vision
    Rees, Gwyneth
    Fenwick, Eva K.
    Keeffe, Jill E.
    Mellor, David
    Lamoureux, Ecosse L.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (12) : 1328 - 1336
  • [42] ORIENTATION OF BLIND AND LOW VISION PATIENTS
    GUROVICH, L
    PENERINI, Y
    METABOLIC OPHTHALMOLOGY, 1978, 2 (2-4): : 369 - 370
  • [43] Strabismus Surgery in Patients with Low Vision
    Yurdakul, Nazife Sefi
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2013, 43 (05): : 313 - 316
  • [44] A review of rehabilitation of low vision patients
    Oduntan, O. A.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2008, 67 (04): : 166 - 175
  • [45] Optical Care in Low Vision Patients
    von Livonius, Bettina
    AUGENHEILKUNDE UP2DATE, 2018, 8 (02) : 111 - 121
  • [46] Magnetic resonance imaging respirators: a randomized crossover trial to assess respiratory protection, usability, and comfort
    Williams, Daryl Lindsay
    Kave, Benjamin
    Bodas, Charles
    Roberts, Megan
    Ng, Irene
    ANTIMICROBIAL STEWARDSHIP & HEALTHCARE EPIDEMIOLOGY, 2024, 4 (01):
  • [47] Comparative Study of Hyperacuity and Retinometer Tests for the Evaluation of Vision in Patients with Advanced Cataract
    George C Woo
    Brian Brown
    眼科学报, 1997, (03) : 164 - 166+161
  • [48] Central Field Defects and Reading Errors in Low Vision Patients Analyzed With Binocular Low Tech Tests
    Fletcher, D. C.
    Schuchard, R. A.
    Wada, J.
    Villani, G. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [49] Challenges to use of low vision assistive devices among patients with residual vision
    Akuffo, Kwadwo Owusu
    Kyeremeh, Sylvester
    Duah, Isaiah Junior Osei
    Danquah, Princella Oye
    Tchiakpe, Michel Pascal
    Boateng, Josephine
    Koomson, Nana Yaa
    Owusu, Emmanuel
    Eisenbarth, Werner
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [50] Usability in the app Interface Designing for the Elderly with Low-Vision in Taiwan and Thailand
    Kunaratana-angkul, Yosssarund
    Wu, Ko-chiu
    Shin-Renn, Yu
    PROCEEDINGS OF THE 2ND IEEE EURASIA CONFERENCE ON BIOMEDICAL ENGINEERING, HEALTHCARE AND SUSTAINABILITY 2020 (IEEE ECBIOS 2020): BIOMEDICAL ENGINEERING, HEALTHCARE AND SUSTAINABILITY, 2020, : 64 - 67