A Randomized Crossover Study to Assess the Usability of Two New Vision Tests in Patients with Low Vision

被引:4
|
作者
Jolly, Jasleen K. [1 ,2 ]
Gray, Joanna M. [2 ]
Salvetti, Anna Paola [1 ,2 ]
Han, Ruofan C. [1 ,2 ]
MacLaren, Robert E. [1 ,2 ]
机构
[1] Univ Oxford, Nuffield Dept Clin Neurosci, Nuffield Lab Ophthalmol, Oxford, England
[2] John Radcliffe Hosp, Oxford Eye Hosp, Oxford Biomed Res Ctr, Oxford, England
关键词
FREIBURG VISUAL-ACUITY; PERFORMANCE; VARIABILITY; RELIABILITY; MOTION; CHARTS; PAPER;
D O I
10.1097/OPX.0000000000001380
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE Well-established charts such as Early Treatment Diabetic Retinopathy Study are able to quantify visual acuity (VA) with a low cutoff of 1.6 logMAR. Below this point, nonquantitative measures, such as count fingers, hand movements, and light perception, are used. There is a need for more reproducible, comparable, and reliable ways to measure VA changes in this patient cohort. PURPOSE The purpose of this study was to examine and compare the ability of the Berkeley Rudimentary Vision Test (BRVT) and the Freiburg Acuity Test (FrACT) to quantify VA in low-vision patients who score nonnumerical VAs in standard charts. METHODS Fifty adult participants with VA <= 1.0 logMAR in both eyes were recruited from the Oxford Eye Hospital, Oxford, United Kingdom. Correlation between FrACT and BRVT results and the correlation between VA and daily living activities were analyzed statistically. Potential predictors of differences were investigated. RESULTS The BRVT was significantly faster to conduct (P = .002), but FrACT was able to quantify vision numerically in a greater proportion of eyes. The kappa agreement between tests was 0.26. The difference increased systematically with the VA reduction (P < .0001). The Bland-Altman analysis showed a skew to measurement of lower logMAR VA indicating better vision measured on the FrACT. The only significant predictor of difference between the tests was binocular VA (coefficient, -0.445; P = .001). CONCLUSIONS Both tests are suitable for a very low-vision population. The BRVT is a faster test to administer, but FrACT provides a numerical result in more eyes. The poor intertest repeatability indicates that they cannot be used interchangeably. The BRVT generally reported poorer vision than did the FrACT. The medium of presentation, such as a computer screen or externally lit print medium, is likely to be the biggest factor in these differences and warrants further investigation.
引用
收藏
页码:443 / 452
页数:10
相关论文
共 50 条
  • [1] Usability of smartphone apps as reading aids for low vision patients
    Eliseo da Silva, Paula Baptista
    Leal, Ariadne Stavare
    Ferraz, Nivea Nunes
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2022, 17 (07) : 848 - 852
  • [2] Screen Magnification for Readers with Low Vision: A Study on Usability and Performance
    Tang, Meini
    Manduchi, Roberto
    Chung, Susana
    Prado, Raquel
    PROCEEDINGS OF THE 25TH INTERNATIONAL ACM SIGACCESS CONFERENCE ON COMPUTERS AND ACCESSIBILITY, ASSETS 2023, 2023,
  • [3] Usability evaluation of smartphone apps as reading aid in low vision patients
    Cavascan, Nivea Nunes
    Eliseo da Silva, Paula Baptista
    Oh, Hye Lim
    da Silva Santos, Carla Ribeiro
    Bois, Bruna Roman
    Leal, Ariadne Stavare
    Nakanami, Celia Regina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [4] Color vision testing in patients with acquired color deficiency and low-vision. Results of two oversized hue discrimination tests
    Schroeder, BU
    Otto, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S429 - S429
  • [5] The effect of low vision rehabilitation on the quality of life and caregiver burden of low vision patients - a randomized trial
    Cai, Chunling
    Shuai, Yuwei
    Li, Gonghui
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [6] Comparison of two color vision tests in patients with Usher syndrome
    Chapon, Mathias
    Audo, Isabelle S.
    Costa, Aureline
    Nassisi, Marco
    Said, Saddek Mohand
    Sahel, Jose-Alain
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [7] Designing for people with low vision: Learnability, usability and measurability
    Harrison, CM
    CONTEMPORARY ERGONOMICS 2004, 2004, : 124 - 129
  • [8] Testing the Usability of Serious Game for Low Vision Children
    Othman, Nurul Izzah
    Mohamed, Hazura
    Zin, Nor Azan Mat
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2023, 14 (08) : 310 - 317
  • [9] Vision-specific and psychosocial impacts of low vision among patients with low vision at the eastern regional Low Vision Centre
    Adamptey, Beatrice
    Naidoo, Kovin S.
    Govender, Pirindhavellie
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2018, 77 (01):
  • [10] The eRDS v6 Stereotest and the Vivid Vision Stereo Test: Two New Tests of Stereoscopic Vision
    Denkinger, Sylvie
    Antoniou, Maria-Paraskevi
    Tarello, Demetrio
    Levi, Dennis M.
    Backus, Benjamin T.
    Bavelier, Daphne
    Chopin, Adrien
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (03):