Is complete axillary dissection necessary for all patients with positive findings on sentinel lymph node biopsy? Validation of a breast cancer nomogram for predicting the likelihood of a non-sentinel lymph node

被引:0
|
作者
Amanti, Claudio [1 ]
Lombardi, Augusto [1 ]
Maggi, Stefano [1 ]
Moscaroli, Alessandra [1 ]
Lo Russo, Marzia [1 ]
Maglio, Riccardo [1 ]
Provenza, Giuseppe [1 ]
Romano, Camilla [1 ]
Pezzatini, Massimo [1 ]
Scopinaro, Francesco [2 ]
Di Stefano, Domenica [3 ]
机构
[1] Univ Roma La Sapienza, Osped San Andrea, Fac Med 2, Operat Unit Chirurg Senol, Rome, Italy
[2] Univ Roma La Sapienza, Osped San Andrea, Fac Med 2, Operat Unit Med Nucl, Rome, Italy
[3] Univ Roma La Sapienza, Osped San Andrea, Fac Med 2, Operat Unit Anat Patol, Rome, Italy
关键词
breast cancer; intraoperative pathologic evaluation; sentinel lymph node; LYMPHADENECTOMY; CARCINOMA;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim and background. Axillary dissection in patients positive for sentinel lymph nodes is currently under discussion in the literature, since approximately only 50% of such patients has metastases in the remaining lymph nodes. To identify patients at risk for non-sentinel lymph nodes metastases, a nomogram was developed by the Breast Service of the Memorial Sloan-Kettering Cancer Center. The aim of this study was to assess the nomogram's predictive accuracy in a population of Italian breast cancer patients in our hospital. Materials and methods. The system of calculation used as variables prognostic factors of breast cancer: pathologic size, tumor type and nuclear grade, lymphovascular invasion, multifocality, estrogen receptor status, method of detection of the sentinel lymph nodes metastases (frozen section, serial hematoxylin-eosin, routine hematoxylin-eosin, and immunohistochemistry), number of positive and number of negative sentinel lymph nodes. Results and conclusions. To measure the discrimination of the nomogram, a receiver-operating characteristic curve was construed, and the area under the curve was calculated. However, the area under the curve was 0.72, a very high value considering that the limit of acceptability is 0.70-0.80. The calculation system developed by the Memorial Sloan-Kettering Cancer Center provides a predictive value oil the histopathologic state of sentinel lymph nodes.
引用
收藏
页码:153 / 155
页数:3
相关论文
共 50 条
  • [21] Prediction of non-sentinel lymph node involvement in breast cancer patients with a positive sentinel lymph node
    Reynders, Anneleen
    Brouckaert, Olivier
    Smeets, Ann
    Laenen, Annouschka
    Yoshihara, Emi
    Persyn, Frederik
    Floris, Giuseppe
    Leunen, Karin
    Amant, Frederic
    Soens, Julie
    Van Ongeval, Chantal
    Moerman, Philippe
    Vergote, Ignace
    Christiaens, Marie-Rose
    Staelens, Gracienne
    Van Eygen, Koen
    Vanneste, Alain
    Van Dam, Peter
    Colpaert, Cecile
    Neven, Patrick
    BREAST, 2014, 23 (04): : 453 - 459
  • [22] A nomogram predictive of non-sentinel lymph node involvement in breast cancer patients with a sentinel lymph node micrometastasis
    Houvenaeghel, G.
    Nos, C.
    Giard, S.
    Mignotte, H.
    Esterni, B.
    Jacquemier, J.
    Buttarelli, M.
    Classe, J. -M.
    Cohen, M.
    Rouanet, P.
    Llorca, F. Penault
    Bonnier, P.
    Marchal, F.
    Garbay, J. -R.
    Fraisse, J.
    Martel, P.
    Fondrinier, E.
    de Lara, C. Tunon
    Rodier, J. -F.
    EJSO, 2009, 35 (07): : 690 - 695
  • [23] Validation of the Memorial Sloan Kettering Cancer Center nomogram for predicting non-sentinel lymph node metastasis in sentinel lymph node-positive breast-cancer patients
    Bi, Xiang
    Wang, Yongsheng
    Li, Minmin
    Chen, Peng
    Zhou, Zhengbo
    Liu, Yanbing
    Zhao, Tong
    Zhang, Zhaopeng
    Wang, Chunjian
    Sun, Xiao
    Qiu, Pengfei
    ONCOTARGETS AND THERAPY, 2015, 8 : 487 - 493
  • [24] Non-sentinel lymph node removal in axillary lymph node evaluation: Is it necessary?
    Kim, S.
    Youn, H. J.
    Jung, S. H.
    EUROPEAN JOURNAL OF CANCER, 2014, 50 : S135 - S135
  • [25] Use and limitations of a nomogram predicting the likelihood of non-sentinel node involvement after a positive sentinel node biopsy in breast cancer patients
    Kocsis, L
    Svébis, M
    Boross, G
    Sinkó, M
    Maráz, R
    Rajtár, M
    Cserni, G
    AMERICAN SURGEON, 2004, 70 (11) : 1019 - 1024
  • [26] MRI-Based Radiomics Nomogram: Prediction of Axillary Non-Sentinel Lymph Node Metastasis in Patients With Sentinel Lymph Node-Positive Breast Cancer
    Qiu, Ya
    Zhang, Xiang
    Wu, Zhiyuan
    Wu, Shiji
    Yang, Zehong
    Wang, Dongye
    Le, Hongbo
    Mao, Jiaji
    Dai, Guochao
    Tian, Xuwei
    Zhou, Renbing
    Huang, Jiayi
    Hu, Lanxin
    Shen, Jun
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [27] A New Model for Predicting Non-Sentinel Lymph Node Status in Chinese Sentinel Lymph Node Positive Breast Cancer Patients
    Liu, Miao
    Wang, Shu
    Pan, Lu
    Yang, Deqi
    Xie, Fei
    Liu, Peng
    Guo, Jiajia
    Zhang, Jiaqing
    Zhou, Bo
    PLOS ONE, 2014, 9 (08):
  • [28] The predictive probability of four different breast cancer nomograms for non-sentinel axillary lymph node metastasis in positive sentinel lymph node biopsy
    Gur, S. A.
    Unal, B.
    Johnson, R.
    Ahrendt, G.
    Bonaventura, M.
    Soran, A.
    CANCER RESEARCH, 2009, 69 (02) : 88S - 88S
  • [29] Validation and limitations of use of a breast cancer nomogram predicting the likelihood of non-sentinel node involvement after positive sentinel node biopsy.
    Alran, S.
    De Rycke, Y.
    Fourchotte, V
    Chritansky, H.
    Salmon, R. J.
    BREAST CANCER RESEARCH AND TREATMENT, 2006, 100 : S80 - S80
  • [30] Breast cancer with micrometastases detected by sentinel lymph node biopsy:: is full axillary lymph node dissection necessary?
    Rodriguez-Gasen, A.
    Bajen, M. T.
    Benitez, A.
    Guiroa, S.
    Rodriguez-Bel, L.
    Pernas, S.
    Gil, M.
    Ortega, R.
    Pla, M. J.
    Catala, I.
    Martin-Comin, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S144 - S144