Capillary pumps with constant flow rate

被引:9
|
作者
van der Wijngaart, Wouter [1 ]
机构
[1] KTH Royal Inst Technol, Micro & Nanosyst Dept, S-10044 Stockholm, Sweden
关键词
Constant flow rates - Design parameters - Hydrodynamic flows - Micropillar arrays - Rectangular cross-sections - Taylor series approximation - Velocity profiles - Volumetric flow rate;
D O I
10.1007/s10404-014-1365-3
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper unambiguously derives, ab initio starting from the Navier-Stokes and Laplace equations, the geometric parameters defining capillary pumps (CPs) with rectangular cross section with constant volumetric flow rate and steady velocity profile. The parametric formulation of the channel shape is derived using Taylor series approximations of the capillary pressure and the hydrodynamic flow resistance with negligible error. First, the design parameters are derived for a CP consisting of a single channel and illustrated with an example. Thereafter, the design parameters for multichannel and for micropillar array CPs are derived. Finally, the design of CPs for multistep constant flow rates derived and those for arbitrarily varying flow rates are discussed.
引用
收藏
页码:829 / 837
页数:9
相关论文
共 50 条
  • [31] FLOW CURVES RELATED TO CONSTANT STRAIN RATE
    REE, A
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 1972, 16 (01): : 40 - &
  • [32] Optimal heating rate in constant pressure and constant flow gas chromatography
    Merrick, Mark
    Blumberg, Leonid M.
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (17) : 3254 - 3267
  • [33] PRESSURE-FLOW RATE CHARACTERISTICS OF THE PUMPS WITH PERMANENT MAGNETS
    Bucenieks, I.
    Kravalis, K.
    Krishbergs, R.
    MAGNETOHYDRODYNAMICS, 2011, 47 (01): : 97 - 104
  • [34] Cam shape and theoretical flow rate in balanced vane pumps
    Giuffrida, A
    Lanzafame, R
    MECHANISM AND MACHINE THEORY, 2005, 40 (03) : 353 - 369
  • [35] Influence of temperature on the flow rate of Baxter™ elastomeric infusion pumps
    Ehrmann, S.
    Delpech, M.
    Fusciardi, J.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 106 - 106
  • [36] Clinical protocols for titrating constant flow implantable pumps in patients with pain or spasticity
    Faaberg, J
    Koulousakis, A
    Staats, PS
    NEUROMODULATION, 2005, 8 (02): : 121 - 130
  • [37] Studies of the rate constant of sucrose hydrolysis by capillary electrophoresis with electrochemical detection
    Ye, JN
    Jin, W
    Zhao, XW
    Fang, YZ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1998, 19 (01): : 31 - 34
  • [38] Rarefied gas flow rate in poiseuille flow through a circular capillary
    V. V. Zhvick
    Fluid Dynamics, 2015, 50 : 711 - 720
  • [39] Controlling Capillary Flow Rate on Lateral Flow Test Substrates by Tape
    Xiao, Zhiqing
    Yang, Yuqian
    Zhang, Xingwei
    Guo, Weijin
    MICROMACHINES, 2021, 12 (05)
  • [40] Rarefied gas flow rate in poiseuille flow through a circular capillary
    Zhvick, V. V.
    FLUID DYNAMICS, 2015, 50 (05) : 711 - 720