In Vitro Hydrolytic Degradation of Polyester-Based Scaffolds under Static and Dynamic Conditions in a Customized Perfusion Bioreactor

被引:16
|
作者
Alaman-Diez, Pilar [1 ]
Garcia-Gareta, Elena [1 ,2 ]
Francisco Napal, Pedro [1 ]
Arruebo, Manuel [3 ,4 ]
Angeles Perez, Maria [1 ]
机构
[1] Univ Zaragoza, Inst Invest Ingn Aragon I3A, Inst Invest Sanitaria Aragon IIS Aragon, Multiscale Mech & Biol Engn, Zaragoza 50018, Spain
[2] UCL, UCL Eastman Dent Inst, Div Biomat & Tissue Engn, London WC1E 6BT, England
[3] Univ Zaragoza, Inst Nanociencia & Mat Aragon INMA, Consejo Super Invest Cient CSIC, Zaragoza 50018, Spain
[4] Univ Zaragoza, Dept Chem Engn, Campus Rio Ebro Edificio I D,C Poeta Mariano Esqu, Zaragoza 50018, Spain
关键词
biomaterials; scaffolds; degradation; hydrolysis; polyester-based materials; flow perfusion; POLYMER SCAFFOLDS; PCL SCAFFOLDS; TISSUE; PLGA; BIODEGRADATION; REGENERATION; FABRICATION; DELIVERY; FRACTURE; DESIGN;
D O I
10.3390/ma15072572
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Creating biofunctional artificial scaffolds could potentially meet the demand of patients suffering from bone defects without having to rely on donors or autologous transplantation. Three-dimensional (3D) printing has emerged as a promising tool to fabricate, by computer design, biodegradable polymeric scaffolds with high precision and accuracy, using patient-specific anatomical data. Achieving controlled degradation profiles of 3D printed polymeric scaffolds is an essential feature to consider to match them with the tissue regeneration rate. Thus, achieving a thorough characterization of the biomaterial degradation kinetics in physiological conditions is needed. Here, 50:50 blends made of poly(s-caprolactone)-Poly(D,L-lactic-co-glycolic acid (PCL-PLGA) were used to fabricate cylindrical scaffolds by 3D printing (empty set 7 x 2 mm). Their hydrolytic degradation under static and dynamic conditions was characterized and quantified. For this purpose, we designed and in-house fabricated a customized bioreactor. Several techniques were used to characterize the degradation of the parent polymers: X-ray Photoelectron Spectroscopy (XPS), Gel Permeation Chromatography (GPC), Scanning Electron Microscopy (SEM), evaluation of the mechanical properties, weigh loss measurements as well as the monitoring of the degradation media pH. Our results showed that flow perfusion is critical in the degradation process of PCL-PLGA based scaffolds implying an accelerated hydrolysis compared to the ones studied under static conditions, and up to 4 weeks are needed to observe significant degradation in polyester scaffolds of this size and chemical composition. Our degradation study and characterization methodology are relevant for an accurate design and to tailor the physicochemical properties of polyester-based scaffolds for bone tissue engineering.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] In vitro static and dynamic cell culture study of novel bone scaffolds based on 3D-printed PLA and cell-laden alginate hydrogel
    Noroozi, Reza
    Shamekhi, Mohammad Amin
    Mahmoudi, Reza
    Zolfagharian, Ali
    Asgari, Fatemeh
    Mousavizadeh, Ali
    Bodaghi, Mahdi
    Hadi, Amin
    Haghighipour, Nooshin
    BIOMEDICAL MATERIALS, 2022, 17 (04)
  • [42] Filter Cake Properties of Water-Based Drilling Fluids Under Static and Dynamic Conditions Using Computed Tomography Scan
    Elkatatny, Salaheldin
    Mahmoud, Mohamed
    Nasr-El-Din, Hisham A.
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2013, 135 (04):
  • [43] Stress-strain and degradation behaviour of railway ballast under static and dynamic loading, based on large-scale triaxial testing
    Indraratna, B
    Salim, W
    Ionescu, D
    Christie, D
    PROCEEDINGS OF THE FIFTEENTH INTERNATIONAL CONFERENCE ON SOIL MECHANICS AND GEOTECHNICAL ENGINEERING VOLS 1-3, 2001, : 2093 - 2096
  • [44] In vitro growth of human urinary tract smooth muscle cells on laminin and collagen type I-coated membranes under static and dynamic conditions
    Hubschmid, U
    Leong-Morgenthaler, PM
    Basset-Dardare, A
    Ruault, S
    Frey, P
    TISSUE ENGINEERING, 2005, 11 (1-2): : 161 - 171
  • [45] In vitro stimulation of vascular endothelial growth factor by borate-based glass fibers under dynamic flow conditions
    Chen, Sisi
    Yang, Qingbo
    Brow, Richard K.
    Liu, Kun
    Brow, Katherine A.
    Ma, Yinfa
    Shi, Honglan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 73 : 447 - 455
  • [46] Model-Based Investigation of PEMFC Catalyst Layer Degradation Behavior Under Dynamic Conditions Considering the Evolution of Transfer Coefficient
    Zhang, Xuexia
    Liao, Hongbo
    Huang, Lei
    Huang, Ruike
    Jiang, Yu
    Liu, Wentao
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2025, 11 (01): : 3182 - 3193
  • [47] Interval prediction of fuel cell degradation based on voltage signal frequency characteristics with TimesNet-GPR under dynamic conditions
    Zhu, Wenchao
    Li, Yongjia
    Xu, Yafei
    Zhang, Leiqi
    Guo, Bingxin
    Xiong, Rui
    Xie, Changjun
    JOURNAL OF CLEANER PRODUCTION, 2025, 486
  • [48] Degradation of waste polycarbonate via hydrolytic strategy to recover monomer (bisphenol A) catalyzed by DBU-based ionic liquids under metal- and solvent-free conditions
    Liu, Mengshuai
    Guo, Jiao
    Gu, Yongqiang
    Gao, Jun
    Liu, Fusheng
    POLYMER DEGRADATION AND STABILITY, 2018, 157 : 9 - 14
  • [49] Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions
    Ya. I. Korenman
    T. A. Kumchenko
    N. Yu. Strashilina
    I. V. Aristov
    L. J. V. Rajakovic
    D. G. Antonovic
    Journal of Analytical Chemistry, 2000, 55 : 893 - 898
  • [50] Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions
    Korenman, YI
    Kumchenko, TA
    Strashilina, NY
    Aristov, IV
    Rajakovic, LJV
    Antonovic, DG
    JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 55 (09) : 893 - 898