Development of electrochemical biosensor for detection of pathogenic microorganism in Asian dust events

被引:29
|
作者
Yoo, Min-Sang [1 ]
Shin, Minguk [1 ]
Kim, Younghun [1 ]
Jang, Min [2 ]
Choi, Yoon-E [3 ]
Park, Si Jae [4 ]
Choi, Jonghoon [5 ]
Lee, Jinyoung [6 ]
Park, Chulhwan [1 ]
机构
[1] Kwangwoon Univ, Dept Chem Engn, 20 Gwangun Ro, Seoul 01897, South Korea
[2] Kwangwoon Univ, Dept Environm Engn, 20 Gwangun Ro, Seoul 01897, South Korea
[3] Korea Univ, Div Environm Sci & Ecol Engn, 145 Anam Ro, Seoul 02841, South Korea
[4] Ewha Womans Univ, Div Chem Engn & Mat Sci, 52 Ewhayeodae Gil, Seoul 03760, South Korea
[5] Chung Ang Univ, Sch Integrat Engn, 84 Heukseok Ro, Seoul 06974, South Korea
[6] Sangmyung Univ, Dept Plant & Food Sci, 31 Sangmyungdae Gil, Cheonan Si 31066, Chungcheongnam, South Korea
基金
新加坡国家研究基金会;
关键词
Bacillus subtilis; Asian dust events; Biosensor; Carbon nanotubes; Pathogen; PLASMON RESONANCE BIOSENSOR; CARBON NANOTUBES; IDENTIFICATION; SALMONELLA; BACTERIA; FOOD;
D O I
10.1016/j.chemosphere.2017.02.060
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
developed a single-walled carbon nanotubes (SWCNTs)-based electrochemical biosensor for the detection of Bacillus subtilis, one of the microorganisms observed in Asian dust events, which causes respiratory diseases such as asthma and pneumonia. SWCNTs plays the role of a transducer in biological antigen/antibody reaction for the electrical signal while 1-pyrenebutanoic acid succinimidyl ester (1-PBSE) and ant-B. subtilis were performed as a chemical linker and an acceptor, respectively, for the adhesion of target microorganism in the developed biosensor. The detection range (10(2)-10(10) CFU/mL) and the detection limit (10(2) CFU/mL) of the developed biosensor were identified while the response time was 10 min. The amount of target B. subtilis was the highest in the specificity test of the developed biosensor, compared with the other tested microorganisms (Staphylococcus aureus, Flavobacterium psychrolimnae, and Aquabacterium commune). In addition, target B. subtilis detected by the developed biosensor was observed by scanning electron microscope (SEM) analysis. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:269 / 274
页数:6
相关论文
共 50 条
  • [31] Development of an Electrochemical Impedimetric Biosensor for the Detection of Telomerase Activity in Cancer Cells
    Diaz-Cartagena, D. C.
    Hernandez-Cancel, G.
    Bracho-Rincon, D. P.
    Gonzalez-Feliciano, J. A.
    Cunci, L.
    Gonzalez, C. I.
    Cabrera, C. R.
    SELECTED PROCEEDINGS FROM THE 231ST ECS MEETING, 2017, 77 (11): : 1833 - 1840
  • [32] Development and properties of a polypyrrole-based electrochemical biosensor for cholesterol detection
    Zhang, Xiu-Hua
    Wan, Kai
    Liang, Zhen-Xing
    Jin, Feng
    Piao, Jin-Hua
    Modern Food Science and Technology, 2015, 31 (04) : 170 - 174
  • [33] Design and Development of a Non-Enzymatic Electrochemical Biosensor for the Detection of Glutathione
    Kannappan, Shrute
    Prabakaran, Lakshmishri
    Nesakumar, Noel
    Babu, K. Jayanth
    Kulandaisamy, Arockia Jayalatha
    Rayappan, John Bosco Balaguru
    ELECTROANALYSIS, 2023, 35 (01) : 245 - 255
  • [34] Development of conducting paper-based electrochemical biosensor for procalcitonin detection
    Gupta, Yachana
    Ghrera, Aditya Sharma
    ADMET AND DMPK, 2023, 11 (02): : 263 - 275
  • [35] Development of electrochemical biosensor for detection of Ag+ ions in aqueous medium
    Pal, Chittatosh
    Majumder, Subrata
    MATERIALS TODAY-PROCEEDINGS, 2020, 29 : 1176 - 1178
  • [36] Development of an electrochemical maltose biosensor
    Moron, Carlos
    Tremps, Enrique
    Garcia, Alfonso
    Andres Somolinos, Jose
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS, 2012, 495 : 116 - +
  • [37] The Development and Application of Electrochemical Biosensor
    Xiang, Qian
    INFORMATION AND MANAGEMENT ENGINEERING, PT V, 2011, 235 : 215 - 220
  • [38] Development of a new dust index NDLI for Asian dust extraction system based on Aqua MODIS data and monitoring of trans-boundary Asian dust events in Japan
    Kazi, Kalpoma A.
    Nagatani, Izumi
    Kawano, Koichi
    Kudoh, Jun-Ichi
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2019, 40 (03) : 1030 - 1047
  • [39] Electrochemical biosensor detection on respiratory and flaviviruses
    Ang, Phaik Ching
    Perumal, Veeradasan
    Ibrahim, Mohamad Nasir Mohamad
    Adnan, Rohana
    Azman, Daruliza Kernain Mohd
    Gopinath, Subash C. B.
    Raja, Pandian Bothi
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2023, 107 (5-6) : 1503 - 1513
  • [40] A novel electrochemical biosensor for detection of cholesterol
    Lin Xu
    Yiting Hou
    Mengdan Zhang
    Xin Yang
    Greath Jenkins
    Wei Huang
    Cheng Yao
    Qiong Wu
    Russian Journal of Electrochemistry, 2016, 52 : 239 - 244