Measured spatially variant system response for PET image reconstruction

被引:0
|
作者
Alessio, Adam M. [1 ]
Kinahan, Paul E. [1 ]
Harrison, Robert L. [1 ]
Lewellen, Thomas K. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
PET; quantitation; statistical reconstruction; system modeling; PSF;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Quantitative accuracy in PET imaging is essential for longitudinal studies and monitoring tumor response to treatment. The goal of this work is to improve the quantitative accuracy of whole-body PET imaging through the use of an accurate, measured system model. Past empirically measured system response functions used line sources positioned at various locations in the imaging field of view. Here, we present a practical method for measuring the detector blurring component of a whole-body PET system with a non-collimated point source. We employ Monte Carlo simulations to show that a non-collimated point source is acceptable for modeling the radial blurring present in a PET tomograph. And, we justify the use of a Na22 point source for collecting these measurements. We measure the system response, simplify it to a two-dimensional function, and incorporate a parameterized version of this response into a modified OSEM algorithm. Reconstructions of measured data from an image quality and tine source phantom reveal improved quantitative accuracy and resolution with the modified system model.
引用
收藏
页码:1986 / 1990
页数:5
相关论文
共 50 条
  • [21] Image reconstruction by conditional entropy maximisation for PET system
    Mondal, PP
    Rajan, K
    IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 2004, 151 (05): : 345 - 352
  • [22] A portable PET image reconstruction system for parallel machines
    Jeng, WM
    Huang, SHS
    Yang, DJ
    11TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 1998, : 137 - 142
  • [23] PET image reconstruction with allowance for errors in the system model
    Brankov, JG
    Djordjevic, J
    Galatsanos, NP
    Wernick, MN
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1163 - 1167
  • [24] Optimization of image reconstruction for the RatCAP (PET) tomograph: An analysis of the statistical quality of the system response matrix
    Southekal, Sudeepti S.
    Purschke, Martin
    Schlyer, David J.
    Woody, Craig L.
    Vaska, Paul
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3051 - +
  • [25] IMAGE RECONSTRUCTION IN PET
    Laforest, Richard
    MOMENTO-REVISTA DE FISICA, 2015, (50E): : 22 - 33
  • [26] Full Field Spatially-Variant Image-Based Resolution Modelling Reconstruction for the HRRT
    Angelis, Georgios I.
    Kotasidis, Fotis A.
    Matthews, Julian C.
    Markiewicz, Pawel J.
    Lionheart, William R.
    Reader, Andrew J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3434 - 3438
  • [27] Full field spatially-variant image-based resolution modelling reconstruction for the HRRT
    Angelis, Georgios I.
    Kotasidis, Fotis A.
    Matthews, Julian C.
    Markiewicz, Pawel J.
    Lionheart, William R.
    Reader, Andrew J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (02): : 137 - 145
  • [28] Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction
    Fessler, JA
    Booth, SD
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 1999, 8 (05) : 688 - 699
  • [29] CATADIOPTRIC IMAGE DENOISING: A SPATIALLY VARIANT APPROACH
    Phan, T. D. K.
    Pham, C. T.
    EURASIAN JOURNAL OF MATHEMATICAL AND COMPUTER APPLICATIONS, 2023, 11 (02): : 82 - 98
  • [30] Spatially variant PSF modeling and image deblurring
    Thiebaut, Erie
    Denis, Loic
    Soulez, Ferreol
    Mourya, Rahul
    ADAPTIVE OPTICS SYSTEMS V, 2016, 9909