Energy management of WSN-based charge measurement system of ultra high-voltage direct-current transmission line

被引:6
|
作者
Deng, Dawei [1 ]
Yuan, Haiwen [1 ]
Cui, Yong [1 ]
Ju, Yong [1 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
关键词
Low power consumption; Energy management; Wireless sensor network; Space charge density measurement; Electromagnetic environment; WIRELESS SENSOR NETWORKS;
D O I
10.1007/s11276-016-1419-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the construction of ultra-high-voltage direct current (UHVDC) transmission lines, the complex electromagnetic environment around the lines has been a widespread concern. The ZigBee-based field measurement system is widely used in ground space charge density measurements of HVDC transmission projects. In actual use, the power consumption of the space charge density measurement system is a key limitation of the device performance.Research on low-power and energy-management strategies of this measurement system can improve the device lifetimes. This capability is very important for improving monitoring efficiency of the surrounding electromagnetic environment of HVDC transmission projects.
引用
收藏
页码:1667 / 1681
页数:15
相关论文
共 50 条
  • [32] Analysis of ice disasters on ultra-high-voltage direct-current transmission lines
    Jiazheng Lu
    Jun Guo
    Jianping Hu
    Li Yang
    Tao Feng
    [J]. Natural Hazards, 2017, 86 : 203 - 217
  • [33] MODULATION OF TRANSFER COEFFICIENT OF RESISTIVE SEPARATORS DURING MEASUREMENT OF HIGH-VOLTAGE DIRECT-CURRENT
    GRUDEV, KL
    [J]. PRIBORY I TEKHNIKA EKSPERIMENTA, 1972, (02): : 138 - &
  • [34] Linear programming techniques for developing an optimal electrical system including high-voltage direct-current transmission and storage
    Clack, C. T. M.
    Xie, Y.
    MacDonald, A. E.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 68 : 103 - 114
  • [35] Development and Application of a Wireless Sensor for Space Charge Density Measurement in an Ultra-High-Voltage, Direct-Current Environment
    Xin, Encheng
    Ju, Yong
    Yuan, Haiwen
    [J]. SENSORS, 2016, 16 (10)
  • [36] A fault location method based on genetic algorithm for high-voltage direct current transmission line
    Li, Yongli
    Zhang, Shuo
    Li, Hongbo
    Zhai, Yongchang
    Zhang, Weiya
    Nie, Yao
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2012, 22 (06): : 866 - 878
  • [37] THE EFFECT OF HIGH-VOLTAGE PULSED DIRECT-CURRENT ON MICROVESSEL PERMEABILITY
    REED, BV
    [J]. PHYSICAL THERAPY, 1987, 67 (05): : 765 - 765
  • [38] Novel protection scheme for high-voltage direct-current transmission lines based on one-terminal transient AC voltage
    Zhang, Yunke
    Li, Yongli
    Song, Jinzhao
    Li, Botong
    Chen, Xiaolong
    Zeng, Liang
    [J]. JOURNAL OF ENGINEERING-JOE, 2019, (17): : 4480 - 4485
  • [39] Effects of Conditional Changes on High-Voltage Direct Current Transmission Line Characteristic
    Pothisarn, Chaichan
    Ngaopitakkul, Atthapol
    Leelajindakrairerk, Monthon
    Phannil, Natthanon
    Bunjongjit, Sulee
    Thongsuk, Surakit
    Sreewirote, Bancha
    [J]. JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2022, 2022
  • [40] HIGH-VOLTAGE DIRECT-CURRENT UNDERGROUND TRANSMISSION TO METROPOLITAN AREAS AND BENEFITS OF A COMPACT TERMINAL DESIGN
    DANFORS, P
    NAATZ, RA
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (04): : 1068 - 1068