Energy management of WSN-based charge measurement system of ultra high-voltage direct-current transmission line

被引:6
|
作者
Deng, Dawei [1 ]
Yuan, Haiwen [1 ]
Cui, Yong [1 ]
Ju, Yong [1 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
关键词
Low power consumption; Energy management; Wireless sensor network; Space charge density measurement; Electromagnetic environment; WIRELESS SENSOR NETWORKS;
D O I
10.1007/s11276-016-1419-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the construction of ultra-high-voltage direct current (UHVDC) transmission lines, the complex electromagnetic environment around the lines has been a widespread concern. The ZigBee-based field measurement system is widely used in ground space charge density measurements of HVDC transmission projects. In actual use, the power consumption of the space charge density measurement system is a key limitation of the device performance.Research on low-power and energy-management strategies of this measurement system can improve the device lifetimes. This capability is very important for improving monitoring efficiency of the surrounding electromagnetic environment of HVDC transmission projects.
引用
收藏
页码:1667 / 1681
页数:15
相关论文
共 50 条
  • [1] Energy management of WSN-based charge measurement system of ultra high-voltage direct-current transmission line
    Dawei Deng
    Haiwen Yuan
    Yong Cui
    Yong Ju
    [J]. Wireless Networks, 2018, 24 : 1667 - 1681
  • [2] WSN-Based Measurement of Ion-Current Density Under High-Voltage Direct Current Transmission Lines
    Cui, Yong
    Song, Xiao
    Zhao, Luxing
    Yuan, Haiwen
    Wu, Guifang
    Wang, Chen
    [J]. IEEE ACCESS, 2019, 7 : 10947 - 10955
  • [3] POWER-LINE CARRIER SYSTEM OF CABORA BASSA HIGH-VOLTAGE DIRECT-CURRENT TRANSMISSION-LINE
    SENN, W
    [J]. BROWN BOVERI REVIEW, 1977, 64 (08): : 460 - 461
  • [4] Hybrid High-voltage Direct-current Transmission System Based on Unidirectional Current Modular Multilevel Converter
    Yang, Wenbo
    Song, Qiang
    Liu, Wenhua
    Xu, Shukai
    Rao, Hong
    Zhu, Zhe
    [J]. Gaodianya Jishu/High Voltage Engineering, 2018, 44 (07): : 2205 - 2212
  • [5] Development of a sensor for corona current measurement under high-voltage direct-current transmission lines
    Xin, Encheng
    Yuan, Haiwen
    [J]. INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2016, 12 (08):
  • [6] Fundamental Concepts in High-Voltage Direct-Current Power Transmission
    Long, W. F.
    Litzenberger, W.
    [J]. 2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [8] Transient measured impedance-based protection scheme for DC line faults in ultra high-voltage direct-current system
    Liu, Jian
    Tai, Nengling
    Fan, Chunju
    Yang, Yayu
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (14) : 3597 - 3609
  • [9] Design and Application of Corona Current Measurement System under High-Voltage Direct-Current Environment
    Xin Encheng
    Yuan Haiwen
    Xu Rui
    Lu Jiayu
    [J]. 2015 FIFTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2015, : 691 - 695
  • [10] Protection scheme for high-voltage direct-current transmission lines based on transient AC current
    Liu, Jian
    Tai, Nengling
    Fan, Chunju
    Huang, Wentao
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (16) : 2633 - 2643