Flow injection chemiluminescence determination of thiamine based on its enhancing effect on the luminol-hydrogen peroxide system

被引:38
|
作者
Du, JX [1 ]
Li, YH [1 ]
Lu, JR [1 ]
机构
[1] Shaanxi Normal Univ, Dept Chem, Sch Chem & Mat Sci, Xian 710062, Peoples R China
关键词
thiamine; flow injection; chemiluminescence; luminol;
D O I
10.1016/S0039-9140(02)00079-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow injection chemiluminescence (CL) method is proposed for the determination of thiamine, based upon its enhancing effect on the CL reaction of luminol with hydrogen peroxide in alkaline solution. The method allows the determination of thiamine within 0.05-8 mug ml(-1) range with a detection limit (3sigma) of 0.01 mug ml(-1). The relative standard deviation is 1.4% (n = 11, 0.5 mug ml(-1) thiamine) and the sample throughput is about 90 samples h(-1). The method was successfully applied to the determination of thiamine in pharmaceutical preparations. (C) 2002 Elsevier Science: B.V. All rights reserved.
引用
收藏
页码:661 / 665
页数:5
相关论文
共 50 条
  • [41] 'Reagentless' Flow Analysis Determination of Hydrogen Peroxide by Electrocatalyzed Luminol Chemiluminescence
    Atwater, J. E.
    Akse, J. R.
    DeHart, J.
    Wheeler, R. R.
    Analytical Letters, 30 (01):
  • [42] On the effect of hydrogen peroxide on the flow-injection determination of platinum based on luminol chemiluminescent reaction
    Malejko, J.
    Milewska, R.
    Lesniewska, B.
    Godlewska-Zylkiewicz, B.
    Kojlo, A.
    ANALYTICAL LETTERS, 2007, 40 (05) : 961 - 973
  • [43] Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Martín, J
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) : 189 - 194
  • [44] Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection
    Tomás Pérez-Ruiz
    Carmen Martínez-Lozano
    Virginia Tomás
    Jesús Martín
    Analytical and Bioanalytical Chemistry, 2003, 377 : 189 - 194
  • [45] Automatic screening of antioxidants based on the evaluation of kinetics of suppression of chemiluminescence in a luminol-hydrogen peroxide system using a sequential injection analysis setup with a flow-batch detection cell
    Chladkova, Gabriela
    Kunovska, Klara
    Chocholous, Petr
    Polasek, Miroslav
    Sklenarova, Hana
    ANALYTICAL METHODS, 2019, 11 (19) : 2531 - 2536
  • [46] Flow-injection chemiluminescence determination of catecholamines based on their enhancing effects on the luminol-potassium periodate system
    Yao, H
    Sun, YY
    Lin, XH
    Cheng, JH
    Huang, LY
    LUMINESCENCE, 2006, 21 (02) : 112 - 117
  • [47] Luminol-hydrogen peroxide-horseradish peroxidase chemiluminescence intensification by kosmotrope ammonium sulfate
    Karatani, Hajime
    ANALYTICAL SCIENCES, 2022, 38 (03) : 613 - 621
  • [48] DETERMINATION OF PROMETHAZINE BY ITS INHIBITION OF THE CHEMILUMINESCENCE OF THE LUMINOL HYDROGEN-PEROXIDE CHROMIUM(III) SYSTEM
    ALWARTHAN, AA
    ALTAMRAH, SA
    AKEL, AA
    ANALYTICA CHIMICA ACTA, 1993, 282 (01) : 169 - 174
  • [49] Chemiluminescence system of luminol-manganese-tetrasulfonatophthalocyanine hydrogen peroxide and its appheation to the determination of proteins
    Li, YX
    Zhao, DH
    Zhuo, SJ
    Zhu, CQ
    Wang, L
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (05) : 638 - 638
  • [50] Multivariate versus univariate calibration for nonlinear chemiluminescence data -: Application to chromium determination by luminol-hydrogen peroxide reaction
    Tortajada-Genaro, LA
    Campíns-Falcó, P
    Verdú-Andrés, J
    Bosch-Reig, F
    ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) : 155 - 173