Flow injection chemiluminescence determination of thiamine based on its enhancing effect on the luminol-hydrogen peroxide system

被引:38
|
作者
Du, JX [1 ]
Li, YH [1 ]
Lu, JR [1 ]
机构
[1] Shaanxi Normal Univ, Dept Chem, Sch Chem & Mat Sci, Xian 710062, Peoples R China
关键词
thiamine; flow injection; chemiluminescence; luminol;
D O I
10.1016/S0039-9140(02)00079-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow injection chemiluminescence (CL) method is proposed for the determination of thiamine, based upon its enhancing effect on the CL reaction of luminol with hydrogen peroxide in alkaline solution. The method allows the determination of thiamine within 0.05-8 mug ml(-1) range with a detection limit (3sigma) of 0.01 mug ml(-1). The relative standard deviation is 1.4% (n = 11, 0.5 mug ml(-1) thiamine) and the sample throughput is about 90 samples h(-1). The method was successfully applied to the determination of thiamine in pharmaceutical preparations. (C) 2002 Elsevier Science: B.V. All rights reserved.
引用
收藏
页码:661 / 665
页数:5
相关论文
共 50 条
  • [1] Flow injection chemiluminescence determination of fenitrothion pesticide using luminol-hydrogen peroxide system
    Liu, Xiaoyu
    Li, Aifang
    Wu, Chengmou
    Lu, Jiuru
    [J]. ANALYTICAL LETTERS, 2007, 40 (14) : 2737 - 2746
  • [2] Determination of monocrotophos pesticide by flow injection chemiluminescence method using luminol-hydrogen peroxide system
    Du, JX
    Liu, XY
    Lu, JR
    [J]. ANALYTICAL LETTERS, 2003, 36 (05) : 1029 - 1038
  • [3] Flow-injection chemiluminescence study of luminol-hydrogen peroxide-carbendazim system
    Liao, Sulan
    Xie, Zenghong
    [J]. SPECTROSCOPY LETTERS, 2006, 39 (05) : 473 - 485
  • [4] The effect of cyclodextrins on the luminol-hydrogen peroxide chemiluminescence
    Voicescu, Mariana
    Ionita, Gabriela
    Vasilescu, Marilena
    Meghea, Aurelia
    [J]. JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2006, 54 (3-4) : 217 - 219
  • [5] The Effect of Cyclodextrins on the Luminol-Hydrogen Peroxide Chemiluminescence
    Mariana Voicescu
    Gabriela Ionita
    Marilena Vasilescu
    Aurelia Meghea
    [J]. Journal of inclusion phenomena and macrocyclic chemistry, 2006, 54 : 217 - 219
  • [6] Droplet detector for the continuous flow luminol-hydrogen peroxide chemiluminescence system
    Wen, Yaqiong
    Yuan, Hongyan
    Mao, Jianfei
    Xiao, Dan
    Choi, Martin M. F.
    [J]. ANALYST, 2009, 134 (02) : 354 - 360
  • [7] Determination of phenol by flow-injection with chemiluminescence detection based on the hemin-catalysed luminol-hydrogen peroxide reaction
    Liu, Wenwen
    Cao, Wei
    Liu, Weihua
    Du, Kang
    Gong, Pixue
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 85 (01) : 283 - 287
  • [8] Chemiluminescence determination of epicatechin by luminol-hydrogen peroxide-copper(II) system
    Li, MJ
    Wang, JZ
    Liu, XH
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (05) : 613 - 613
  • [9] Automated Sequential-injection Chemiluminescence Determination of Glucosamine Sulphate via Luminol-Hydrogen Peroxide System
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (10) : 1246 - 1252
  • [10] Flow system for the automatic screening of the effect of phenolic compounds on the luminol-hydrogen peroxide-peroxidase chemiluminescence system
    Araujo, Andre R. T. S.
    Maya, Fernando
    Saraiva, M. Lucia M. F. S.
    Lima, Jose L. F. C.
    Estela, Jose M.
    Cerda, Victor