Arterial to end-tidal carbon dioxide tension difference in anaesthetized adults mechanically ventilated via a laryngeal mask or a cuffed oropharyngeal airway

被引:0
|
作者
Casati, A [1 ]
Fanelli, G [1 ]
Cappelleri, G [1 ]
Albertin, A [1 ]
Anelati, D [1 ]
Magistris, L [1 ]
Torri, G [1 ]
机构
[1] Univ Milan, IRCCS H San Raffaele, Dept Anaesthesiol, I-20132 Milan, Italy
关键词
anaesthesia general; isoflurane; airway; laryngeal mask; cuffed oropharyngeal airway; mechanical ventilation; monitoring; carbon dioxide; arterial-alveolar gradients;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
To evaluate arterial (PaCO2), end-tidal (PETCO2) and carbon dioxide tension difference during mechanical ventilation with extratracheal airways, 60 patients ASA physical status I-II, receiving general anaesthesia for minor extra-abdominal procedures were randomly allocated to receive either a cuffed oropharyngeal airway (group COPA, n=30) or a laryngeal mask (group LMA, n=30). The lungs were mechanically ventilated by IPPV using a 60% nitrous oxide and 1-1.5% isoflurane in oxygen mixture (V-T=8 mL kg(-1); RR=12 b min(-1); I/E=1/2). After PETCO2 had been stable for at least 10 min after airway placement, haemodynamic variables and PETCO2 were recorded and an arterial blood sample was obtained for measurement of PaCO2. No differences in anthropometric parameters, smoking habit, haemodynamic variables and incidence of untoward events were observed between the two groups. Airway manipulation, to maintain adequate ventilation, was required in only nine patients in the cuffed oropharyngeal airway group (30%) (P<0.0005); however, in no case was it necessary to remove the designated extratracheal airway due to unsuccessful mechanical ventilation. The mean difference between arterial and end-tidal carbon dioxide partial pressure was 0.4+/-0.3 KPa in the laryngeal mask group (95% confidence intervals: 0.3-0.5 KPa) and 0.3+/-0.26 KPa in the cuffed oropharyngeal airway group (95% confidence intervals: 0.24-0.4 KPa) (P=NS). We conclude that in healthy adults who are mechanically ventilated via the cuffed oropharyngeal airway, the end-tidal carbon dioxide determination is as accurate an indicator of PaCO2 as that measured via the laryngeal mask, allowing capnometry to be reliably used to evaluate the adequacy of ventilation.
引用
收藏
页码:534 / 538
页数:5
相关论文
共 50 条
  • [41] Difference between arterial and end-tidal carbon dioxide pressures during laparoscopy in paediatric patients
    M. Laffon
    A. Gouchet
    P. Sitbon
    V. Guicheteau
    E. Biyick
    A. Duchalais
    C. Mercier
    Canadian Journal of Anaesthesia, 1998, 45 : 561 - 563
  • [42] Difference between arterial and end-tidal carbon dioxide pressures during laparoscopy in paediatric patients
    Laffon, M
    Gouchet, A
    Sitbon, P
    Guicheteau, V
    Biyick, E
    Duchalais, A
    Mercier, C
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (06): : 561 - 563
  • [43] Relationship between arterial and end-tidal carbon dioxide pressures during anesthesia using a laryngeal tube
    Lee, JS
    Nam, SB
    Chang, CH
    Han, DW
    Lee, YW
    Shin, CS
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (06) : 759 - 762
  • [44] THE RELIABILITY OF SIDE-STREAM END-TIDAL CO2 CAPNOGRAPHY FOR ESTIMATING ARTERIAL CARBON DIOXIDE TENSION IN MECHANICAL VENTILATED CHILDREN
    Truin, G.
    Verhaeg, J.
    van der Hoeven, J.
    Lemson, J.
    INTENSIVE CARE MEDICINE, 2011, 37 : S326 - S327
  • [45] High alveolar-arterial oxygen and end tidal-arterial carbon dioxide gradients in mechanically ventilated rats
    Heavner, JE
    LABORATORY ANIMAL SCIENCE, 1999, 49 (05): : 476 - 479
  • [46] The gradient of arterial carbon dioxide to end-tidal carbon dioxide levels over the first week after birth in ventilated newborn infants
    Bednarczuk, Nadja
    Williams, Emma
    Dassios, Theodore
    Greenough, Anne
    PEDIATRIC RESEARCH, 2021, 90 (SUPPL 1) : 40 - 40
  • [47] ESTIMATION OF ARTERIAL CARBON-DIOXIDE BY END-TIDAL AND TRANSCUTANEOUS PCO2 MEASUREMENTS IN VENTILATED CHILDREN
    SIVAN, Y
    ELDADAH, MK
    CHEAH, TE
    NEWTH, CJL
    PEDIATRIC PULMONOLOGY, 1992, 12 (03) : 153 - 157
  • [48] STABILITY OF THE ARTERIAL TO END-TIDAL CARBON-DIOXIDE DIFFERENCE DURING ANESTHESIA FOR PROLONGED NEUROSURGICAL PROCEDURES
    SHARMA, SK
    MCGUIRE, GP
    CRUISE, CJE
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (06): : 498 - 503
  • [49] Arterial-to-end-tidal carbon dioxide tension difference in children with congenital heart disease
    Choudhury, M
    Kiran, U
    Choudhary, SK
    Airan, B
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (02) : 196 - 201
  • [50] Cost-efficient end-tidal carbon dioxide monitoring via Hudson-style mask
    Kempen, P
    ANESTHESIOLOGY, 1999, 91 (04) : 1176 - 1177