Novel Simulation Model with Pulsatile Flow System for Microvascular Training, Research, and Improving Patient Surgical Outcomes

被引:15
|
作者
Gallardo, Federico Carlos [1 ]
Bustamante, Jorge Luis [1 ,2 ]
Martin, Clara [1 ]
Orellana, Cristian Marcelo [1 ]
Caviglia, Mauricio Rojas [1 ]
Oriola, Guillermo Garcia [3 ]
Diaz, Agustin Ignacio [1 ]
Rubino, Pablo Augusto [1 ]
Quesada, Vicent Quilis [3 ,4 ,5 ]
机构
[1] Hosp Alta Complejidad El Cruce, Dept Neurosurg, Buenos Aires, DF, Argentina
[2] Univ Nacl La Plata, Fac Ciencias Med, Lab Programa Trasplante Organos & Tejidos, La Plata, Argentina
[3] Univ Valencia, Hosp Clin, Dept Neurosurg, Valencia, Spain
[4] Mayo Clin, Coll Med & Sci, Dept Neurosurg, Rochester, MN USA
[5] Univ Valencia, Dept Human Anat & Embryol, Div Neuroanat, Fac Med & Dent, Valencia, Spain
关键词
Anastomosis; Aneurysm; Microsurgery; Neurosurgery; Placenta; Training Simulation; HUMAN-PLACENTA; VASCULAR ANASTOMOSIS; TECHNICAL SKILL; SURGERY; FIDELITY; IMPACT; CIRCULATION; ACQUISITION; PERFORMANCE;
D O I
10.1016/j.wneu.2020.07.116
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Simulation allows surgical trainees to acquire surgical skills in a safe environment. With the aim of reducing the use of animal experimentation, different alternative nonliving models have been pursued. However, one of the main disadvantages of these nonliving models has been the absence of arterial flow, pulsation, and the ability to integrate both during a procedure on a blood vessel. In the present report, we have introduced a microvascular surgery simulation training model that uses a fiscally responsible and replicable pulsatile flow system. METHODS: We connected 30 human placentas to a pulsatile flow system and used them to simulate aneurysm clipping and vascular anastomosis. RESULTS: The presence of the pulsatile flow system allowed for the simulation of a hydrodynamic mechanism similar to that found in real life. In the aneurysm simulation, the arterial flow could be evaluated before and after clipping the aneurysm using a Doppler ultrasound system. When practicing anastomosis, the use of the pulsatile flow system allowed us to assess the vascular flow through the anastomosis, with verification using the Doppler u ltrasound system. Leaks were manifested as "blood" pulsatile ejections and were more frequent at the begin-n ing of the surgical practice, showing a learning curve. CONCLUSIONS: We have provided a step-by-step guide for the assembly of a replicable and inexpensive pulsatile flow system and its use in placentas for the simulation of, and training in, performing different types of anastomoses and intracranial aneurysms surgery.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 43 条
  • [41] Development of Surgical Error Reduction System (SERS) for Laparoscopic Appendectomy by using Observational Human Reliability Analysis (OCHRA) model and to analyse its impact on patient outcomes
    Muthukumarasamy, Girivasan
    Zino, Samer
    Tang, Benjie
    Patil, Pradeep
    INTERNATIONAL JOURNAL OF SURGERY PROTOCOLS, 2022, 26 (01):
  • [42] Outcomes of focussed training of intravenous catheter (IVC) placement using point of care ultrasound scan (POCUS) to junior doctors in the surgical department using a novel porcine based model
    Golpe, A. Leyte
    Ertansel, B.
    Thomas, P.
    BRITISH JOURNAL OF SURGERY, 2018, 105 : 162 - 162
  • [43] Simulation of blood flow and vessel deformation in three-dimensional, patient-specific models of the cardiovascular system using a novel method for fluid-solid interactions
    Figueroa, A
    Vignon-Clementel, I
    Jansen, K
    Hughes, TJR
    Taylor, CA
    Fluid Structure Interaction and Moving Boundary Problems, 2005, 84 : 143 - 152