Silver nanodendrite modified graphene rotating disk electrode for nonenzymatic hydrogen peroxide detection

被引:36
|
作者
Sawangphruk, Montree [1 ,2 ]
Sanguansak, Yanisa [1 ]
Krittayavathananon, Atiweena [1 ]
Luanwuthi, Santamon [1 ]
Srimuk, Pattarachai [1 ]
Nilmoung, Sukanya [3 ]
Maensiri, Santi [3 ]
Meevasana, Worawat [3 ]
Limtrakul, Jumras [2 ,4 ,5 ,6 ]
机构
[1] Kasetsart Univ, Dept Chem Engn, Natl Ctr Excellence Petr Petrochem & Adv Mat, Fac Engn, Bangkok 10900, Thailand
[2] Kasetsart Univ, Ctr Adv Studies Nanotechnol & Its Applicat Chem F, Bangkok 10900, Thailand
[3] Suranaree Univ, Inst Sci, Sch Phys, Nakhon Ratchasima 30000, Thailand
[4] Kasetsart Univ, Dept Chem, Bangkok 10900, Thailand
[5] Kasetsart Univ, NANOTEC Ctr Nanoscale Mat Design Green Nanotechno, Bangkok 10900, Thailand
[6] PTT Publ Co Ltd, PTT Grp Frontier Res Ctr, Bangkok 10900, Thailand
关键词
GLASSY-CARBON ELECTRODE; AG NANOPARTICLES; SUBSEQUENT DECORATION; FACILE SYNTHESIS; DENDRITIC NANOSTRUCTURES; REPLACEMENT REACTION; OXIDE NANOCOMPOSITE; STABILIZING AGENT; GRAPHITE OXIDE; RAMAN-SPECTRA;
D O I
10.1016/j.carbon.2014.01.010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Although silver nanostructures have been widely used for H2O2 detection, the development of silver based nanomaterials with higher performance toward H2O2 detection is still needed. In this work, metallic silver nanodendrite (AgND) modified reduced graphene oxide (rGO) electrode with open pore structure was prepared by an electrodeposition method and used for H2O2 detection. The rotating disk electrode (RDE) was used to study the convective diffusion effect of H2O2 to the electrode. The performance of the AgND/rGO electrode toward H2O2 detection significantly depends on the rotation rate of the electrode. At the rotation rates of 0 and 100 rpm, the as-fabricated electrode could not detect H2O2. At higher rotation rates, wide linear ranges of detected H2O2 concentrations with a determination coefficient R-2 of over 0.99 are found to be 1-100, 0.5-100, 0.1-100, and 0.05-30 mM at the electrode rotation rates of 500, 1000, 2000, and 6000 rpm, respectively. The LOD values determined at a signal-to-noise ratio of ca. 3 are about 100, 50, 30, and 10 mu M at 500, 1000, 2000, and 6000 rpm, respectively. The as-fabricated electrode can detect diluted H2O2 in milk demonstrating its potential sensing application. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [2] Nonenzymatic amperometric determination of hydrogen peroxide by graphene and gold nanorods nanocomposite modified electrode
    Pang, Pengfei
    Yang, Zhongming
    Xiao, Shixiu
    Xie, Jinling
    Zhang, Yanli
    Gao, Yuntao
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 727 : 27 - 33
  • [3] A novel nonenzymatic hydrogen peroxide sensor based on reduced graphene oxide/ZnO composite modified electrode
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Sarawathi, Ramiah
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 372 - 377
  • [4] Electrochemically Reduced Graphene Oxide Film Modified Electrode for Detection of Hydrogen Peroxide
    Li, Juan
    Yang, Juan
    Yang, Zhan-jun
    Ji, Ping
    Zhou, Yi-mei
    Diao, Guo-wang
    PROGRESS IN FUNCTIONAL MATERIALS, 2013, 538 : 165 - 168
  • [5] DECOMPOSITION OF HYDROGEN-PEROXIDE AT A ROTATING SILVER DISK IN ALKALINE MEDIUM
    BREZINA, M
    KORYTA, J
    LANPHUON.PT
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1972, 40 (01): : 107 - &
  • [6] A novel nonenzymatic hydrogen peroxide sensor based on Pd nanoparticles modified electrode
    Zhuang, Zhenjing
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 790 - 794
  • [7] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 911 - 916
  • [8] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [9] Pd nanoparticle-modified electrodes for nonenzymatic hydrogen peroxide detection
    Wang, Jue
    Chen, Xue-jiao
    Liao, Kai-ming
    Wang, Guang-hou
    Han, Min
    NANOSCALE RESEARCH LETTERS, 2015, 10
  • [10] Pd nanoparticle-modified electrodes for nonenzymatic hydrogen peroxide detection
    Jue Wang
    Xue-jiao Chen
    Kai-ming Liao
    Guang-hou Wang
    Min Han
    Nanoscale Research Letters, 2015, 10