Determination of the spatial distribution of neutron fluence rate using printed activation foil arrays

被引:2
|
作者
Kim, Jiseok [1 ,2 ]
Yim, Chewook [2 ]
Lee, Han Rim [1 ]
Kim, Yongkyun [2 ]
机构
[1] Korea Atom Energy Res Inst, 111 Daedeok Daero,989 Beon Gil, Deajeon, South Korea
[2] Hanyang Univ, Dept Nucl Engn, Seoul, South Korea
关键词
Neutron; Activation foil; Semiconductor printing; Fluence rate determination;
D O I
10.1007/s10967-018-5856-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method to fabricate neutron activation foil arrays using a semiconductor printing technique is proposed; it allows higher resolutions, and fast and convenient fabrication. A validation irradiation test is performed, using a traditional array and the proposed printed array. The latter exhibited higher resolution and avoided the spatial distortion of the traditional foil array which can reach several tens of percent. Furthermore, it can be easily bent and made to use small individual foils (1 mm or less), making it suitable to measure neutron spatial distributions at the curved surfaces of pipes or the inner surface of irradiation passages.
引用
收藏
页码:1027 / 1032
页数:6
相关论文
共 50 条
  • [21] Determination of fluence rate distribution in a multilayered skin tissue model by using Monte Carlo simulations
    Arslan, Halil
    Pehlivanoz, Bahar
    TURKISH JOURNAL OF PHYSICS, 2019, 43 (03): : 286 - 292
  • [22] Neutron diagnostics using nickel foil activation analysis in the KSTAR
    Chae, San
    Lee, Jae-Yong
    Kim, Yong-Soo
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (09) : 3012 - 3017
  • [23] Neutron spectrum determination of accelerator-driven d(10)+Be neutron source using the multi-foil activation technique
    Stefanik, Milan
    Simeckova, Eva
    Bem, Pavel
    Stursa, Jan
    Zach, Vaclav
    Mrazek, Jaromir
    RADIATION PHYSICS AND CHEMISTRY, 2022, 190
  • [24] EPITHERMAL-NEUTRON SPECTRUM DETERMINATION USING A PLURAL FOIL
    DEKKER, AL
    NUCLEAR APPLICATIONS AND TECHNOLOGY, 1969, 7 (02): : 179 - &
  • [25] DETERMINATION OF HIGH INTEGRAL THERMAL-NEUTRON FLUXES BY GOLD FOIL ACTIVATION
    DANIS, A
    SANDU, M
    SAVU, V
    REBIGAN, F
    REVUE ROUMAINE DE PHYSIQUE, 1971, 16 (10): : 1213 - &
  • [26] DETERMINATION OF IRON AND URANIUM IN HIGH PURITY LEAD FOIL BY NEUTRON ACTIVATION ANALYSIS
    BENSON, PA
    SMITH, RH
    HOLLAND, WD
    ANALYTICAL CHEMISTRY, 1962, 34 (09) : 1113 - &
  • [27] Determination of neutron fluence using the plot of isotope variation of cadmium and gadolinium
    Tomiyoshi, IA
    Iyer, SS
    Rodrigues, C
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 237 (1-2) : 85 - 89
  • [28] Determination of neutron fluence using the plot of isotope variation of cadmium and gadolinium
    I. A. Tomiyoshi
    S. S. Iyer
    C. Rodrigues
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 237 : 85 - 89
  • [29] Determination of neutron fluence using the plot of isotope variation of cadmium and gadolinium
    I. A. Tomiyoshi
    S. S. Iyer
    C. Rodrigues
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 240 : 705 - 705
  • [30] Determination of the fluoride distribution in rabbit bone using instrumental neutron activation analysis
    T. P. Cheng
    H. D. Anderson
    D. S. Mills
    V. L. Spate
    C. K. Baskett
    J. S. Morris
    Journal of Radioanalytical and Nuclear Chemistry, 1997, 217 : 171 - 174