Determination of the spatial distribution of neutron fluence rate using printed activation foil arrays

被引:2
|
作者
Kim, Jiseok [1 ,2 ]
Yim, Chewook [2 ]
Lee, Han Rim [1 ]
Kim, Yongkyun [2 ]
机构
[1] Korea Atom Energy Res Inst, 111 Daedeok Daero,989 Beon Gil, Deajeon, South Korea
[2] Hanyang Univ, Dept Nucl Engn, Seoul, South Korea
关键词
Neutron; Activation foil; Semiconductor printing; Fluence rate determination;
D O I
10.1007/s10967-018-5856-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method to fabricate neutron activation foil arrays using a semiconductor printing technique is proposed; it allows higher resolutions, and fast and convenient fabrication. A validation irradiation test is performed, using a traditional array and the proposed printed array. The latter exhibited higher resolution and avoided the spatial distortion of the traditional foil array which can reach several tens of percent. Furthermore, it can be easily bent and made to use small individual foils (1 mm or less), making it suitable to measure neutron spatial distributions at the curved surfaces of pipes or the inner surface of irradiation passages.
引用
收藏
页码:1027 / 1032
页数:6
相关论文
共 50 条
  • [1] Determination of the spatial distribution of neutron fluence rate using printed activation foil arrays
    Jiseok Kim
    Chewook Yim
    Han Rim Lee
    Yongkyun Kim
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 316 : 1027 - 1032
  • [2] Fabrication of activation foil arrays using printing techniques for evaluation of spatial distribution of neutron flux and energy
    Kim, Jiseok
    Sun, Gwang Min
    Baek, Hani
    Hoang, Sy Minh Tuan
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 2133 - 2136
  • [3] Fabrication of activation foil arrays using printing techniques for evaluation of spatial distribution of neutron flux and energy
    Jiseok Kim
    Gwang Min Sun
    Hani Baek
    Sy Minh Tuan Hoang
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 2133 - 2136
  • [4] DETERMINATION OF THERMAL NEUTRON FLUENCE BY COBALT ACTIVATION MONITORS
    KOHLER, W
    VANINBROUKX, R
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (09): : 529 - +
  • [5] The importance of the direction distribution of neutron fluence, and methods of determination
    Bartlett, DT
    Drake, P
    d'Errico, F
    Luszik-Bhadra, M
    Matzke, M
    Tanner, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 386 - 394
  • [6] Neutron fluence spectrometry using disk activation
    Loevestam, Goeran
    Hult, Mikael
    Fessler, Andreas
    Gasparro, Joel
    Kockerols, Pierre
    Okkinga, Klaas
    Tagziria, Hamid
    Vanhavere, Filip
    Wieslander, J. S. Elisabeth
    RADIATION MEASUREMENTS, 2009, 44 (01) : 72 - 79
  • [7] NEUTRON-SPECTRUM DETERMINATION BY MULTIPLE FOIL ACTIVATION
    TASHANI, HA
    ENERGIA ES ATOMTECHNIKA, 1990, 43 (02): : 64 - 68
  • [8] NEUTRON-FLUX SPECTRAL DETERMINATION BY FOIL ACTIVATION
    MCELROY, WN
    BERG, S
    GIGAS, G
    NUCLEAR SCIENCE AND ENGINEERING, 1967, 27 (03) : 533 - &
  • [9] Determination of Slow-Neutron Fluence Rate Using Gamma-Ray Spectroscopy
    Gawelczyk, B.
    Konefal, A.
    ACTA PHYSICA POLONICA A, 2021, 139 (03) : 280 - 282
  • [10] Determination of radial and axial neutron flux distribution in irradiation channel of NIRR-1 using foil activation technique
    Musa, Y.
    Ahmed, Y. A.
    Yamusa, Y. A.
    Ewa, I. O. B.
    ANNALS OF NUCLEAR ENERGY, 2012, 50 : 50 - 55