A three-dimensional digital image correlation technique for strain measurements in microstructures

被引:229
|
作者
Verhulp, E [1 ]
van Rietbergen, B [1 ]
Huiskes, R [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
关键词
strain measurements; trabecular bone; image correlation; computed tomography;
D O I
10.1016/j.jbiomech.2003.12.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A three-dimensional digital image correlation technique is presented for strain measurements in open-cell structures such as trabecular bone. The technique uses high-resolution computed tomography images for displacement measurements in the solid structure. In order to determine the local strain-state within single trabeculae, a tetrahedronization method is used to fill the solid structure with tetrahedrae. Displacements are calculated at the nodes of the tetrahedrae. The displacement data is subsequently converted to a deformation tensor in each of the tetrahedral element centers with a least-squares estimation method. Because the trabeculae are represented by a mesh, it is possible to deform this mesh according to the deformation tensor and, at the same time, visualize the calculated local strain in the deformed mesh with a finite element post-processing tool. In this way, the deformation of a single trabecula from an aluminum foam sample was determined and validated with rendered images of the three-dimensional sample. A precision analysis showed that a rigid translation or rotation does not affect the accuracy. Typical values for the standard deviation in the displacement and strain components are 2.0 mum and 0.01, respectively. Presently, the precision limits the technique to strain measurements beyond the yield strain. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1313 / 1320
页数:8
相关论文
共 50 条
  • [31] Real-time three-dimensional digital image correlation for biomedical applications
    Wu, Rong
    Wu, Hua
    Arola, Dwayne
    Zhang, Dongsheng
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (10)
  • [32] Three-dimensional digital image correlation measurement of mechanical properties of soft materials
    Wang, Wei-Chung
    Chiang, Yu-An
    Yu, Ken-Jen
    Ho, Yi-Chieh
    Shen, Hung-Tsan
    Chang, Ting-Yu
    Chang, Ya-Hsin
    Tsao, Chun-Sheng
    MECCANICA, 2015, 50 (02) : 419 - 428
  • [33] Application of three-dimensional digital image correlation to the core-drilling method
    M. J. McGinnis
    S. Pessiki
    H. Turker
    Experimental Mechanics, 2005, 45 (4) : 359 - 367
  • [34] Three-dimensional rigid body displacement measurement based on digital image correlation
    Sun, Wei
    He, Xiaoyuan
    Quan, Chenggen
    Zheng, Xiang
    Guangxue Xuebao/Acta Optica Sinica, 2008, 28 (05): : 894 - 901
  • [35] Application of three-dimensional digital image correlation to the core-drilling method
    McGinnis, MJ
    Pessiki, S
    Turker, H
    EXPERIMENTAL MECHANICS, 2005, 45 (04) : 359 - 367
  • [36] Measuring Three-Dimensional Deformation of Underwater Propellers Based on Digital Image Correlation
    Pan Jiyu
    Zhang Shuiqiang
    Su Zhilong
    Wu Shen
    Zhang Dongsheng
    ACTA OPTICA SINICA, 2021, 41 (12)
  • [37] Three-dimensional digital image correlation system for deformation measurement in experimental mechanics
    Tang, Zheng-Zong
    Liang, Jin
    Xiao, Zhen-Zhong
    Guo, Cheng
    Hu, Hao
    OPTICAL ENGINEERING, 2010, 49 (10)
  • [38] Determination of three-dimensional movement for rotary blades using digital image correlation
    Wu, Rong
    Chen, Yue
    Pan, Yanting
    Wang, Qiang
    Zhang, Dongsheng
    OPTICS AND LASERS IN ENGINEERING, 2015, 65 : 38 - 45
  • [39] Three-Dimensional Digital Image Correlation Using a Single Color-Camera
    Gubbels, Wade
    Schajer, Gary S.
    ADVANCEMENT OF OPTICAL METHODS IN EXPERIMENTAL MECHANICS, VOL 3, 2015, : 315 - 324
  • [40] Quantification of Three-Dimensional Surface Deformation using Global Digital Image Correlation
    J. van Beeck
    J. Neggers
    P. J. G. Schreurs
    J. P. M. Hoefnagels
    M. G. D. Geers
    Experimental Mechanics, 2014, 54 : 557 - 570