An Investigation on Cooling Performance of Air-Cooled Heat Exchangers Used in Coal Seam Gas Production

被引:4
|
作者
Lu, Yuanshen [1 ,2 ]
Guan, Zhiqiang [1 ,2 ]
Hooman, Kamel [1 ,2 ]
Parulekar, Prashant S. [3 ]
机构
[1] Queensland Geothermal Energy Ctr Excellence, St Lucia, Qld, Australia
[2] Univ Queensland, Sch Mech & Min Engn, Mansergh Shaw Bldg 45,Cooper Rd, St Lucia, Qld 4072, Australia
[3] Arrow Energy, Brisbane, Qld, Australia
关键词
INTAKE FLOW-RATE; WIND; TOWER;
D O I
10.1080/01457632.2016.1217039
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper reports an investigation into a practical cooling issue on a type of fan-forced finned-tube heat exchangers used in Queensland's coal seam gas (CSG) industry. CSG compression facilities in some production sites suffered underproduction in recent summers because of frequent automatic engine shutdowns. The problem is not expected by the manufacturer's design. However, it is suspected of being related to the control systems on the compression facilities triggering the overheating-protection shutdowns due to possible deficiencies in one or some water/gas cooling loops in the facilities' air-cooled heat exchangers. Therefore, to understand which heat exchangers and what exact reasons cause the unexpected cooling issue, an investigation has been carried out on the cooler units of the gas compression facilities. A field instrumentation measurement on one operating cooler unit has been done, followed by an analysis using a one-dimensional analytical model and a three-dimensional computational fluid dynamics model. The experimental results are used to validate both the models. Then the cooling performance of the cooler unit under the summer peak condition is predicted by the verified models. The prediction suggests that the water inlet temperature in one particular cooler section is higher than its upper limit defined by the manufacturer, due to poor cooling at high ambient temperatures. The lower cooling performance is caused by large reductions in the cooler air speed and total heat transfer coefficient, which are related to less efficiency of the cooler fans, more airflow resistance, and fouling on both sides of the finned tubes.
引用
收藏
页码:1073 / 1088
页数:16
相关论文
共 50 条
  • [1] Air-cooled Heat Exchangers
    S Afr Mech Eng, 10 (35):
  • [2] SPRAY COOLING OF AIR-COOLED COMPACT HEAT-EXCHANGERS
    YANG, WJ
    CLARK, DW
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1975, 18 (02) : 311 - 317
  • [3] AIR-COOLED HEAT EXCHANGERS.
    Zanker, Adam
    Machine Design, 1979, 51 (28) : 158 - 166
  • [4] QUIETER AIR-COOLED HEAT EXCHANGERS
    DRYDEN, SL
    JUDD, SH
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (02): : 9 - &
  • [5] Constructal design of finned tubes used in air-cooled heat exchangers
    Hossein Shokouhmand
    Shoeib Mahjoub
    Mohammad Reza Salimpour
    Journal of Mechanical Science and Technology, 2014, 28 : 2385 - 2391
  • [6] Constructal design of finned tubes used in air-cooled heat exchangers
    Shokouhmand, Hossein
    Mahjoub, Shoeib
    Salimpour, Mohammad Reza
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (06) : 2385 - 2391
  • [7] Effectively design air-cooled heat exchangers
    Mukherjee, R
    CHEMICAL ENGINEERING PROGRESS, 1997, 93 (02) : 26 - 47
  • [8] TROUBLESHOOTING AIR-COOLED HEAT EXCHANGERS.
    Berryman, Bob
    Russell, Charles
    Process Engineering (London), 1985, 66 (04):
  • [9] Modeling air-cooled heat sinks as heat exchangers
    Moffat, Robert J.
    TWENTY-THIRD ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2007, 2007, : 200 - 207
  • [10] ASSESSING AIR-SIDE PERFORMANCE OF AIR-COOLED HEAT EXCHANGERS.
    Berryman, Bob
    Russell, Charles
    Process Engineering (London), 1986, 67 (04):