Implementation of a cryo-electron tomography tilt-scheme optimized for high resolution subtomogram averaging

被引:414
|
作者
Hagen, Wim J. H. [1 ]
Wan, William [1 ]
Briggs, John A. G. [1 ]
机构
[1] European Mol Biol Lab, Struct & Computat Biol Unit, Meyerhofstr 1, Heidelberg, Germany
关键词
Electron tomography; Tilt-scheme; Subtomogram averaging; Cryo-electron microscopy; ELECTRON CRYOTOMOGRAPHY; ALIGNMENT;
D O I
10.1016/j.jsb.2016.06.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cryo-electron tomography (cryoET) allows 3D structural information to be obtained from cells and other biological samples in their close-to-native state. In combination with subtomogram averaging, detailed structures of repeating features can be resolved. CryoET data is collected as a series of images of the sample from different tilt angles; this is performed by physically rotating the sample in the microscope between each image. The angles at which the images are collected, and the order in which they are collected, together are called the tilt-scheme. Here we describe a "dose-symmetric tilt-scheme" that begins at low tilt and then alternates between increasingly positive and negative tilts. This tilt-scheme maximizes the amount of high-resolution information maintained in the tomogram for subsequent subtomogram averaging, and may also be advantageous for other applications. We describe implementation of the tilt-scheme in combination with further data-collection refinements including setting thresholds on acceptable drift and improving focus accuracy. Requirements for microscope set-up are introduced, and a macro is provided which automates the application of the tilt-scheme within SerialEM. (C) 2016 The Authors. Published by Elsevier Inc.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [1] Cryo-Electron Tomography and Subtomogram Averaging
    Wan, W.
    Briggs, J. A. G.
    RESOLUTION REVOLUTION: RECENT ADVANCES IN CRYOEM, 2016, 579 : 329 - 367
  • [2] emClarity: software for high-resolution cryo-electron tomography and subtomogram averaging
    Benjamin A. Himes
    Peijun Zhang
    Nature Methods, 2018, 15 : 955 - 961
  • [3] emClarity: software for high-resolution cryo-electron tomography and subtomogram averaging
    Himes, Benjamin A.
    Zhang, Peijun
    NATURE METHODS, 2018, 15 (11) : 955 - +
  • [4] Advances in cryo-electron tomography and subtomogram averaging and classification
    Zhang, Peijun
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2019, 58 : 249 - 258
  • [5] Toward high-resolution in situ structural biology with cryo-electron tomography and subtomogram averaging
    Schur, Florian K. M.
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2019, 58 : 1 - 9
  • [6] Cryo-electron Tomography Remote Data Collection and Subtomogram Averaging
    Sheng, Yuewen
    Morris, Kyle
    Radecke, Julika
    Zhang, Peijun
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (185):
  • [7] Protocol for subtomogram averaging of helical filaments in cryo-electron tomography
    Zhang, Xiaojie
    Mahamid, Julia
    STAR PROTOCOLS, 2024, 5 (03):
  • [8] High-resolution in situ structure determination by cryo-electron tomography and subtomogram averaging using emClarity
    Tao Ni
    Thomas Frosio
    Luiza Mendonça
    Yuewen Sheng
    Daniel Clare
    Benjamin A. Himes
    Peijun Zhang
    Nature Protocols, 2022, 17 : 421 - 444
  • [9] High-resolution in situ structure determination by cryo-electron tomography and subtomogram averaging using emClarity
    Ni, Tao
    Frosio, Thomas
    Mendonca, Luiza
    Sheng, Yuewen
    Clare, Daniel
    Himes, Benjamin A.
    Zhang, Peijun
    NATURE PROTOCOLS, 2022, 17 (02) : 421 - +
  • [10] In situ cryo-electron tomography and subtomogram averaging of intraflagellar transport trains
    Jordan, Mareike A.
    Pigino, Gaia
    THREE-DIMENSIONAL ELECTRON MICROSCOPY, 2019, 152 : 179 - 195