Quantitative determination of 1-hydroxypyrene in bovine urine samples using high-performance liquid chromatography with fluorescence and mass spectrometric detection

被引:43
|
作者
Ferrari, S
Mandel, F
Berset, JD
机构
[1] Inst Environm Protect & Agr, IUL, CH-3003 Bern, Switzerland
[2] Agilent Technol GMBH, Dept Mass Spectrometry, European Mkt Ctr, D-76337 Waldbronn, Germany
关键词
OHP; SPE; HPLC-FD; HRGC-MS; HPLC-MS; animal urine samples; PAH;
D O I
10.1016/S0045-6535(01)00302-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An analytical method was developed to determine quantitatively 1-hydroxypyrene (OHP) in bovine urine samples. The procedure includes an enzymatic hydrolysis to cleave the conjugated metabolite, an enrichment step using solid phase extraction with a non-polar rinse step and elution with dichloromethane. A final clean-up on silicagel was performed before high-performance liquid chromatography (HPLC) analysis and fluorescence detection. Alternatively, HPLC and electrospray ionization in the negative ion mode applying selective ion monitoring acquisition revealed to be a highly sensitive detection method allowing the quantitation of low pg of OHP in the urine samples. The method was successfully applied to the determination of OHP in bovine urine samples from animals living in urban and rural areas. Urine concentrations of OHP were significantly higher (median 8.6 mug l(-1)) of bovines living close to a highway. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 50 条
  • [1] Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography with fluorescence detection using a deuterated internal standard
    Chetiyanukornkul, T
    Toriba, A
    Kizu, R
    Makino, T
    Nakazawa, H
    Hayakawa, K
    JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (01) : 107 - 112
  • [2] Determination of 1-hydroxypyrene using high-performance liquid chromatography with electrochemical detection
    Barek, J
    Bencko, V
    Cvacka, J
    Mejstrik, V
    Slamova, A
    Svagrova, I
    Zima, J
    CHEMICKE LISTY, 1997, 91 (10): : 871 - 876
  • [3] DETERMINATION OF 1-HYDROXYPYRENE IN HUMAN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HANSEN, AM
    POULSEN, OM
    CHRISTENSEN, JM
    HANSEN, SH
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (01) : 38 - 41
  • [4] AN IMPROVED METHOD FOR THE DETERMINATION OF URINARY 1-HYDROXYPYRENE BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    Lu, Shaoyou
    Fan, Ruifang
    Yu, Zhiqiang
    Sheng, Guoying
    Fu, Jiamo
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (11) : 1528 - 1537
  • [5] Determination of 1-hydroxypyrene in children urine using column-switching liquid chromatography and fluorescence detection
    Kuo, CT
    Chen, HW
    Chen, JL
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02): : 187 - 193
  • [6] Automated column-switching high-performance liquid chromatography method for the determination of 1-hydroxypyrene in human urine
    Simon, P
    Morele, Y
    Delsaut, P
    Nicot, T
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01): : 91 - 101
  • [8] Determination of marbofloxacin in plasma samples by high-performance liquid chromatography using fluorescence detection
    Garcia, MA
    Solans, C
    Aramayona, JJ
    Rueda, S
    Bregante, MA
    JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2): : 157 - 161
  • [9] Quantitative determination of voglibose in pharmaceutical tablets using high-performance liquid chromatography-fluorescence detection with post-column derivatization and mass spectrometric detection
    Woo, Jong Soo
    Ryu, Jae Kuk
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (03) : 328 - 333
  • [10] The use of chemical derivatization to enhance liquid chromatography/tandem mass spectrometric determination of 1-hydroxypyrene, a biomarker for polycyclic aromatic hydrocarbons in human urine
    Li, YH
    Li, AC
    Shi, H
    Zhou, SL
    Shou, WZ
    Jiang, XY
    Weng, ND
    Lauterbach, JH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (22) : 3331 - 3338