Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis

被引:2
|
作者
Erceg, M. [1 ]
Becic, K. [2 ]
机构
[1] Clin Hosp Ctr Split, Dept Orthopaed, Split, Croatia
[2] Univ Split, Sch Med, Split, Croatia
关键词
Austin Moore endoprosthesis; hip rearthroplasty; aseptic loosening; BONE; ASSOCIATION; OSTEOLYSIS; REVISION; CEMENT;
D O I
10.4103/0022-3859.128823
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years). To the best of the author's knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.
引用
收藏
页码:81 / 83
页数:3
相关论文
共 50 条
  • [21] TREATMENT OF INFECTION IN TOTAL HIP-ARTHROPLASTY
    ZILKENS, KW
    FORST, R
    CASSER, HR
    UNFALLCHIRURG, 1989, 92 (07): : 352 - 357
  • [22] Surgical Treatment of Hip Osteoarthritis: Update in Total Hip Arthroplasty
    Ilizaliturri Sanchez, Vector M.
    Mangino Pariente, Gerardo
    Camacho Galindo, Javier
    REUMATOLOGIA CLINICA, 2007, 3 : 57 - 62
  • [23] Identification and treatment of infected total hip arthroplasty
    Zmistowski, Benjamin
    Parvizi, Javad
    EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2012, 10 (04) : 509 - 518
  • [24] TREATMENT OF FRACTURE-DISLOCATION OF HIP BY TOTAL HIP ARTHROPLASTY
    COVENTRY, MB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (06): : 1128 - 1134
  • [25] Comparing total hip arthroplasty and hemiarthroplasty in the treatment of hip fracture
    Tucker, Nicholas J.
    Kamath, Atul F.
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7
  • [26] HIP IMPLANT INFECTION - TREATMENT WITH RESECTION ARTHROPLASTY AND LATE TOTAL HIP-ARTHROPLASTY
    FITZGERALD, RH
    JONES, DR
    AMERICAN JOURNAL OF MEDICINE, 1985, 78 (6B): : 225 - 228
  • [27] Serum Chromium Levels Before and After Revision Surgery for Loosened Metal-On-Metal Total Hip Arthroplasty
    Maezawa, Katsuhiko
    Nozawa, Masahiko
    Matsuda, Keiji
    Sugimoto, Munehiko
    Shitoto, Katsuo
    Kurosawa, Hisashi
    JOURNAL OF ARTHROPLASTY, 2009, 24 (04): : 549 - 553
  • [28] AN UNUSUAL CAUSE OF THIGH PAIN AFTER TOTAL HIP-ARTHROPLASTY
    HIGGS, JED
    CHONG, A
    HAERTSCH, P
    SEKEL, R
    LEICESTER, A
    JOURNAL OF ARTHROPLASTY, 1995, 10 (02): : 203 - 204
  • [29] STRESS-FRACTURE OF THE HIP - AN UNUSUAL COMPLICATION OF TOTAL KNEE ARTHROPLASTY
    HARDY, DCR
    DELINCE, PE
    YASIK, E
    LAFONTAINE, MA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (281) : 140 - 144
  • [30] Unusual cause of third-body wear in total hip arthroplasty
    Diwan, A
    Drummond, R
    JOURNAL OF ARTHROPLASTY, 1997, 12 (05): : 586 - 588