Thermal Analysis of Two-level Wind Power Converter under Symmetrical Grid Fault

被引:0
|
作者
Zhou, Dao [1 ]
Blaabjerg, Frede [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
FED INDUCTION GENERATOR;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the case of symmetrical grid fault when using the multi-MW wind turbine of partial-scale and full-scale two-level power converter are designed and investigated. Firstly, the different operation behaviors of the relevant power converters under the voltage dip will be described and analyzed. Simulations of different configurations regarding the loss distribution and the junction temperature of the power device are presented in respect to the various voltage dips. It is concluded that for both systems the power loss will change dramatically during the Low-Voltage Ride Through (LVRT) condition as well as the junction temperature. For the full-scale wind turbine system, the most thermal stressed power device in the grid-side converter will appear at the grid voltage below 0.5 pu, and for the partial-scale wind turbine system, the most thermal stressed power device in the rotor-side converter will appear around 0.6 pu grid voltage.
引用
收藏
页码:1904 / 1909
页数:6
相关论文
共 50 条
  • [21] Fault detection based on the discrete wavelet transform for the converter of a wind power generator system operating under disturbances in the grid
    de-la-Rosa-Mendoza, San-Jose
    Alvarez-Salas, Ricardo
    Gonzalez-Garcia, Mario
    Cardenas, Victor
    Villalobos-Pina, Francisco-Javier
    Miranda-Vidales, Homero
    [J]. DYNA, 2022, 97 (03): : 249 - 253
  • [22] Analysis of Wind Turbine Structural Loads under Grid Fault
    Song, Zhanfeng
    Xia, Changliang
    Chen, Wei
    [J]. ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2277 - 2282
  • [23] IoT enabled Intelligent Fault Diagnosis System for Two-level Voltage Source Converter
    Banerjee, Swapnil
    Manikandan, R.
    Singh, R. Raja
    Mohan, Harshit
    [J]. 2021 INTERNATIONAL CONFERENCE ON COMPUTATIONAL PERFORMANCE EVALUATION (COMPE-2021), 2021, : 85 - +
  • [24] Control Strategy of Wind Power Converter Under Unbalanced Grid Voltage Condition
    Jiang, Chenhui
    Wang, Zhixin
    [J]. PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 615 - 621
  • [25] Reactive Power Capability of DFIG based Wind Turbine around Synchronous Operating Point with Two-Level and Three-Level NPC Converter
    Sujod, Muhamad Zahim
    Erlich, Istvan
    [J]. 2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [26] A two-level power-grid model for transient current testing evaluation
    Alorda, B
    Canals, V
    Segura, J
    [J]. JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2004, 20 (05): : 543 - 552
  • [27] A Two-Level Power-Grid Model for Transient Current Testing Evaluation
    B. Alorda
    V. Canals
    J. Segura
    [J]. Journal of Electronic Testing, 2004, 20 : 543 - 552
  • [28] Performance characteristics of a cascaded two-level converter
    Corzine, KA
    Sudhoff, SD
    Whitcomb, CA
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (03) : 433 - 439
  • [29] Hybrid CCS/FCS model predictive current control of a grid connected two-level converter
    Iles, Sandor
    Barisa, Tin
    Sumina, Damir
    Matusko, Jadranko
    [J]. 2018 IEEE 18TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (PEMC), 2018, : 981 - 986
  • [30] Power Losses Analysis of Two-Level and Three-Level Neutral Clamped Inverters for a Wind Pump Storage System
    Clotea, L.
    Forcos, A.
    Marinescu, C.
    Georgescu, M.
    [J]. OPTIM 2010: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, PTS I-IV, 2010, : 1174 - 1179