Comparison of nickel-titanium and stainless-steel spreader penetration and accessory cone fit in curved canals

被引:12
|
作者
Schmidt, KJ
Walker, TL
Johnson, JD
Nicoll, BK
机构
[1] Natl Naval Dent Ctr, Naval Dent Sch, Endodont Dept, Bethesda, MD 20889 USA
[2] Natl Naval Dent Ctr, Naval Dent Sch, Adv Specialty Educ Program Endodont, Bethesda, MD 20889 USA
关键词
D O I
10.1097/00004770-200001000-00011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare nickel-titanium and stainless-steel spreader penetration in curved canals. Twenty prepared plastic blocks with a 30 degrees curvature were used for each part of the study. In part 1, the force required to insert each spreader to within 1 mm of working length in an empty canal was measured. In part 2, the force required to insert each spreader to within 3 mm of working length was measured in a canal containing a master cone. In part 3, the depth of penetration of each spreader with a master cone in place using a 1.5 kg force was measured. Additionally, in part 3, the depth of penetration of the first accessory cone was measured. The results from part 1 showed that a nickel-titanium spreader required significantly less force than a stainless-steel spreader (0.30 kg vs. 0.59 kg). In part 2, a nickel-titanium spreader required significantly less force than a stainless-steel spreader (1.56 kg vs. 2.42 kg). In part 3, a nickel-titanium spreader penetrated significantly deeper than a stainless-steel spreader (15.0 mm vs. 14.0 mm). There was no significant difference in the depth of penetration of the first accessory cone used after either spreader (0.8 mm vs. 0.7 mm). Therefore, the potential for vertical root fracture in curved canals during lateral condensation may be minimized by using nickel-titanium spreaders.
引用
收藏
页码:42 / 44
页数:3
相关论文
共 50 条
  • [21] The accuracy of the root ZX electronic apex locator using stainless-steel and nickel-titanium files
    Thomas, AS
    Hartwell, GR
    Moon, PC
    JOURNAL OF ENDODONTICS, 2003, 29 (10) : 662 - 663
  • [22] TIG WELDING OF NICKEL-TITANIUM TO 304 STAINLESS STEEL
    Fox, Gordon
    Hahnlen, Ryan
    Dapino, Marcelo
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS (SMASIS 2011), VOL 1, 2012, : 625 - 632
  • [23] Shaping ability of two rotary instruments in simulated canals: stainless steel ENDOflash and nickel-titanium HERO Shaper
    Perez, F
    Schoumacher, M
    Peli, JF
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (09) : 637 - 644
  • [24] Stainless steel versus niquel titanium files in curved canals.
    Atlas, D
    Leonardi, L
    Raiden, G
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1016 - 1016
  • [25] Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments
    Buerklein, S.
    Boerjes, L.
    Schaefer, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (05) : 470 - 476
  • [26] Lifespan of One Nickel-Titanium Rotary File with Reciprocating Motion in Curved Root Canals
    You, Sung-Yeop
    Bae, Kwang-Shik
    Baek, Seung-Ho
    Kum, Kee-Yeon
    Shon, Won-Jun
    Lee, WooCheol
    JOURNAL OF ENDODONTICS, 2010, 36 (12) : 1991 - 1994
  • [27] Torsional properties of stainless steel and nickel-titanium endodontic files
    Rowan, MB
    Nicholls, JI
    Steiner, J
    JOURNAL OF ENDODONTICS, 1996, 22 (07) : 341 - 345
  • [28] Comparison of shaping ability of ProTaper Next and 2Shape nickel-titanium files in simulated severe curved canals
    Staffoli, Simone
    Ozyurek, Taha
    Hadad, Avi
    Lvovsky, Alex
    Solomonov, Michael
    Azizi, Hadas
    Ben Itzhak, Joe
    Bossu, Maurizo
    Grande, Nicola M.
    Plotino, Gianluca
    Polimeni, Antonella
    GIORNALE ITALIANO DI ENDODONZIA, 2018, 32 (02): : 52 - 56
  • [29] Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments
    Samia M.Elsherief
    Mohamed K.Zayet
    Ibrahim M.Hamouda
    The Journal of Biomedical Research, 2013, 27 (04) : 326 - 335
  • [30] Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments
    Elsherief, Samia M.
    Zayet, Mohamed K.
    Hamouda, Ibrahim M.
    JOURNAL OF BIOMEDICAL RESEARCH, 2013, 27 (04): : 326 - 335