Experimental and Numerical Study of Cross-flow Fan in Air-conditioner Indoor Unit

被引:11
|
作者
Zou, Tengda [1 ]
Zhan, Dongwen [1 ]
Hu, Xiaowen [1 ]
Hu, Site [1 ,2 ]
Li, Yeqiang [1 ]
机构
[1] Midea Global Innovat Ctr, Midea Corp Res Ctr, Midea Grp, Foshan, Guangdong, Peoples R China
[2] Midea Grp, Foshan, Peoples R China
关键词
Air -conditioner indoor unit; Cross -flow fan; Eccentric vortex; Recirculation zone; Structure optimization; ECCENTRIC VORTEX; HEAT-TRANSFER; PERFORMANCE; GEOMETRY;
D O I
10.1016/j.ijrefrig.2022.05.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
The cross-flow fan is an essential component of an air-conditioner indoor unit, and its aerodynamic performance seriously affects the performance and heat exchange efficiency of air-conditioning. The internal flow of the crossflow fan is studied by PIV measurements combined with the three-dimensional unsteady simulation. It is observed that the internal flow of the cross-flow fan is unevenly distributed along the axial direction, and it presents prominent three-dimensional characteristics. Due to the influence of the end-wall, the eccentric vortex is strong in the middle and weak at both ends. Therefore, a pressure gradient along the axial direction in the eccentric vortex area, resulting in axial fluid transport inside the eccentric vortex. At the exit of the impeller, there is a small recirculation zone near the end-wall, which grows continually as it moves downstream in the diffuser section, thereby blocking the outlet. This paper further proposes a structure optimization, which effectively enhances the eccentric vortex near the end-wall and reduces the recirculation zone in the diffuser section, resulting in a 2.1% increase in the flow rate of air-conditioner indoor unit and a 0.8dB reduction in noise level. It is indicated that the structure optimization strategy based on the understanding of three-dimensional flow is beneficial to the internal flow and effectively improves the aerodynamic performance and the aeroacoustics performance of the whole air-conditioner indoor unit.
引用
收藏
页码:102 / 111
页数:10
相关论文
共 50 条
  • [31] Remote terminal air-conditioner unit for power management
    Srisuwan, Khomkrit
    Sangmalee, Vansan
    Thunyaphirak, Veera
    Skunpong, Apirak
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 395 - +
  • [32] EFFECT OF THE OUTDOOR UNIT ARRANGEMENTS ON COP OF AN AIR-CONDITIONER
    Li, Hao
    Huang, Chen
    Zou, Zhijun
    Wang, Fei
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2273 - 2278
  • [33] Optimization Design Investigation of Volute tongue in Indoor Air-conditioner
    Wan Zhongmin
    Chen Huanxin
    Lin Kun
    Jin Tingxiang
    Zheng Zuyi
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [34] Thermal flow study of multi-flow condenser for automotive air-conditioner
    Lee, KH
    Won, JP
    Kim, WH
    HEAT TRANSFER 1998, VOL 6: GENERAL PAPERS, 1998, : 113 - 118
  • [35] A systematic experimental approach to cross-flow fan design
    Lazzaretto, A
    Toffolo, A
    Martegani, AD
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (04): : 684 - 693
  • [36] Experimental Study of Energy-Saving Air-Conditioner with Hot Water
    CHEN Jian-bo
    CHEN Dan
    LU Ying(University of Shanghai for Science and Technology
    Shanghai
    China)
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 75 - 78
  • [37] A study on axial flow fan design parameters of air conditioner outdoor unit and the performance improvement
    Chung, MK
    Jin, SW
    Chung, BY
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 856 - 862
  • [38] Experimental study on refrigerant migration of room air-conditioner at starting and stopping
    Shi, WX
    Wang, BL
    Liu, T
    Li, XT
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 660 - 663
  • [39] A Comparative Study Between a Constant-Speed Air-Conditioner and a Variable-Speed Air-Conditioner
    Chen, Ing Youn
    Chen, Y. M.
    Chang, Y. J.
    Wei, C. S.
    Wang, C. C.
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 1, 2009, 115 : 326 - +
  • [40] Visualization measurement and numerical analysis of internal flow in cross-flow fan
    Tsurusaki, H
    Tsujimoto, Y
    Yoshida, Y
    Kitagawa, K
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (03): : 633 - 638