Performance and outcome of the subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction

被引:10
|
作者
Chung, Da-Un [1 ]
Tauber, Johannes [2 ]
Kaiser, Lukas [1 ]
Schlichting, Andrea [1 ]
Pecha, Simon [2 ]
Sinning, Christoph [3 ]
Rexha, Enida [1 ]
Reichenspurner, Hermann [2 ]
Willems, Stephan [1 ]
Gosau, Nils [1 ]
Hakmi, Samer [1 ]
机构
[1] Asklepios Klin St Georg, Dept Cardiol & Crit Care Med, Hamburg, Germany
[2] Univ Heart & Vasc Ctr, Dept Cardiac Surg, Hamburg, Germany
[3] Univ Heart & Vasc Ctr, Dept Cardiol, Hamburg, Germany
来源
关键词
CIED-related infection; lead complications; subcutaneous implantable cardioverter-defibrillator (S-ICD); sudden cardiac death; transvenous lead extraction (TLE); EXPERT CONSENSUS STATEMENT; CLINICAL-OUTCOMES; ASSOCIATION; INFECTION; MANAGEMENT; MORTALITY; REGISTRY; TRENDS; ICD;
D O I
10.1111/pace.14157
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The subcutaneous cardioverter-defibrillator (S-ICD) may be a valuable option in patients after successful transvenous lead extraction (TLE) without indication for pacemaker therapy and persistent risk of sudden cardiac death. The aim of this study was to evaluate device performance, postoperative outcome, and safety in patients who received a S-ICD after TLE compared to patients who underwent de-novo S-ICD implantation. Methods: A retrospective analysis of all patients included into our institution's S-ICD database between September 2010 and May 2019 was conducted.The patients were divided in two groups, depending on whether they had received their S-ICD after TLE (n = 31) or de-novo (n = 113). Results: The TLE group was significantly older with a mean age of 54.3 +/- 15.7 versus 46.7 +/- 14.4 years; p = .007. Leading S-ICD indication in the TLE group was previous infection (50%), whereas in the de-novo group the S-ICD was primarily chosen due to young patient age (74.6%). Median duration of follow-up was 527.0 versus 472.5 days, respectively; p = .576. Most common complication during follow-up was inappropriate ICD therapy (12.9% vs. 13.3%); p = 1.000. Pocket erosion/infection occurred in 3.2% versus 3.5% with no reported cases of systemic (re-)infection in either group; p = 1.000. All-cause mortality was low (6.2% vs. 2.7%) and entirely unrelated to S-ICD implantation or the device itself; p = .293. Conclusion: The S-ICD is a safe and effective alternative for patients after TLE with very similar results regarding device performance and postoperative outcome, when compared to patients who underwent de-novo S-ICD implantation.
引用
收藏
页码:247 / 257
页数:11
相关论文
共 50 条
  • [41] Brugada Syndrome and the Subcutaneous Implantable Cardioverter-Defibrillator
    Nordkamp, Louise R. A. Olde
    Conte, Giulio
    Rosenmoller, Boudewijn R. A. M.
    Warnaars, Joppe L. F.
    Tan, Hanno L.
    Caputo, Maria L.
    Regoli, Francois
    Moccetti, Tiziano
    Auricchio, Angelo
    Knops, Reinoud E.
    Wilde, Arthur A. M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (06) : 665 - 666
  • [42] SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR PLACEMENT IN A PATIENT WITH A PREEXISTING TRANSVENOUS ICD: A CASE FOR DEFIBRILLATOR THRESHOLD TESTING?
    Jazayeri, Mohammad-Ali
    Bartos, Joann
    Tabbert, Ted
    Jazayeri, Mohammad-Reza
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 2297 - 2297
  • [43] Subcutaneous implantable cardioverter-defibrillator in a young woman
    Calvagna, Giuseppe Mario
    Ceresa, Fabrizio
    Patane, Salvatore
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 175 (02) : E30 - E32
  • [44] Comparison of complications and shocks in paediatric and young transvenous and subcutaneous implantable cardioverter-defibrillator patients
    Quast, A. B. E.
    Brouwer, T. F.
    Kooiman, K. M.
    van Dessel, P. F. H. M.
    Blom, N. A.
    Wilde, A. A. M.
    Knops, R. E.
    [J]. NETHERLANDS HEART JOURNAL, 2018, 26 (12) : 612 - 619
  • [45] Use and outcomes of subcutaneous implantable cardioverter-defibrillator (ICD) after transvenous ICD extraction: An analysis of current clinical practice and a comparison with transvenous ICD reimplantation
    Viani, Stefano
    Migliore, Federico
    Tola, Gianfranco
    Pisano, Ennio C. L.
    Dello Russo, Antonio
    Luzzi, Giovanni
    Sartori, Paolo
    Piro, Agostino
    Rordorf, Roberto
    Forleo, Giovanni Battista
    Rago, Anna
    Segreti, Luca
    Bertaglia, Emanuele
    Biffi, Mauro
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Diemberger, Igor
    Bongiorni, Maria Grazia
    [J]. HEART RHYTHM, 2019, 16 (04) : 564 - 571
  • [46] GHOST VEGETATION DEVELOPMENT AFTER DUAL CHAMBER IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEAD EXTRACTION
    Patibandla, Saikrishna
    Monzidelis, Constantine, Jr.
    Buddhavarapu, Sivacharan
    Ayala-Rodriguez, Cesar Esteban
    Reddy, Sarath
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 3248 - 3248
  • [47] Watchful Waiting in an Unusual Cause of Hypoxemia after Implantable Cardioverter-Defibrillator Lead Extraction
    Bejko, Jonida
    Di Bacco, Lorenzo
    Stara, Alessandra
    Manzato, Aldo
    Curnis, Antonio
    Repossini, Alberto
    Muneretto, Claudio
    [J]. ANNALS OF CARDIAC ANAESTHESIA, 2019, 22 (01) : 109 - 110
  • [48] Clinical performance of implantable cardioverter-defibrillator lead monitoring diagnostics
    Poole, Jeanne E.
    Swerdlow, Charles D.
    Tarakji, Khaldoun G.
    Mittal, Suneet
    Ellenbogen, Kenneth A.
    Greenspon, Arnold J.
    Kennergren, Charles
    Philbert, Berit T.
    Moore, JoEllyn
    Jones, R. Chris
    Schaller, Robert D.
    Hansalia, Riple
    Simmers, Timothy
    Mihalcz, Attila
    DeBus, Becky
    Lexcen, Daniel R.
    Gunderson, Bruce
    Wilkoff, Bruce L.
    [J]. HEART RHYTHM, 2022, 19 (03) : 363 - 371
  • [49] Pacemaker/implantable cardioverter-defibrillator problem: Right ventricular lead missensing in a biventricular implantable cardioverter-defibrillator
    Otten, Richard F.
    Foreman, Lynne D.
    Groh, William J.
    [J]. HEART RHYTHM, 2008, 5 (01) : 158 - 159
  • [50] Multicenter Experience With Extraction of the Sprint Fidelis Implantable Cardioverter-Defibrillator Lead
    Martin, David T.
    Hook, Bruce G.
    Chaudhry, G. Muqtada
    Silver, Jonathan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (05) : 635 - 636