Performance and outcome of the subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction

被引:10
|
作者
Chung, Da-Un [1 ]
Tauber, Johannes [2 ]
Kaiser, Lukas [1 ]
Schlichting, Andrea [1 ]
Pecha, Simon [2 ]
Sinning, Christoph [3 ]
Rexha, Enida [1 ]
Reichenspurner, Hermann [2 ]
Willems, Stephan [1 ]
Gosau, Nils [1 ]
Hakmi, Samer [1 ]
机构
[1] Asklepios Klin St Georg, Dept Cardiol & Crit Care Med, Hamburg, Germany
[2] Univ Heart & Vasc Ctr, Dept Cardiac Surg, Hamburg, Germany
[3] Univ Heart & Vasc Ctr, Dept Cardiol, Hamburg, Germany
来源
关键词
CIED-related infection; lead complications; subcutaneous implantable cardioverter-defibrillator (S-ICD); sudden cardiac death; transvenous lead extraction (TLE); EXPERT CONSENSUS STATEMENT; CLINICAL-OUTCOMES; ASSOCIATION; INFECTION; MANAGEMENT; MORTALITY; REGISTRY; TRENDS; ICD;
D O I
10.1111/pace.14157
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The subcutaneous cardioverter-defibrillator (S-ICD) may be a valuable option in patients after successful transvenous lead extraction (TLE) without indication for pacemaker therapy and persistent risk of sudden cardiac death. The aim of this study was to evaluate device performance, postoperative outcome, and safety in patients who received a S-ICD after TLE compared to patients who underwent de-novo S-ICD implantation. Methods: A retrospective analysis of all patients included into our institution's S-ICD database between September 2010 and May 2019 was conducted.The patients were divided in two groups, depending on whether they had received their S-ICD after TLE (n = 31) or de-novo (n = 113). Results: The TLE group was significantly older with a mean age of 54.3 +/- 15.7 versus 46.7 +/- 14.4 years; p = .007. Leading S-ICD indication in the TLE group was previous infection (50%), whereas in the de-novo group the S-ICD was primarily chosen due to young patient age (74.6%). Median duration of follow-up was 527.0 versus 472.5 days, respectively; p = .576. Most common complication during follow-up was inappropriate ICD therapy (12.9% vs. 13.3%); p = 1.000. Pocket erosion/infection occurred in 3.2% versus 3.5% with no reported cases of systemic (re-)infection in either group; p = 1.000. All-cause mortality was low (6.2% vs. 2.7%) and entirely unrelated to S-ICD implantation or the device itself; p = .293. Conclusion: The S-ICD is a safe and effective alternative for patients after TLE with very similar results regarding device performance and postoperative outcome, when compared to patients who underwent de-novo S-ICD implantation.
引用
收藏
页码:247 / 257
页数:11
相关论文
共 50 条
  • [1] SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR AFTER TRANSVENOUS LEAD EXTRACTION: SAFETY, EFFICACY AND OUTCOME
    Migliore, F.
    Giacomin, E.
    Pittorru, R.
    Falzone, P.
    Dall'Aglio, P.
    Vianello, R.
    De Lazzari, M.
    Bertaglia, E.
    Iliceto, S.
    [J]. EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24 (SUPPL C)
  • [2] Subcutaneous implantable cardioverter defibrillator after transvenous lead extraction: safety, efficacy and outcome
    Giacomin, Enrico
    Falzone, Pasquale Valerio
    Dall'Aglio, Pietro Bernardo
    Pittorru, Raimondo
    De Lazzari, Manuel
    Vianello, Riccardo
    Bertaglia, Emanuele
    Tarzia, Vincenzo
    Iliceto, Sabino
    Gerosa, Gino
    Migliore, Federico
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022,
  • [3] SUBCUTANEOUS IMPLANTABLE CARDIOVERTER DEFIBRILLATOR AFTER TRANSVENOUS LEAD EXTRACTION: SAFETY, EFFICACY AND OUTCOME
    Pittorru, Raimondo
    Giacomin, Enrico
    Migliore, Federico
    Falzone, Pasquale
    Dall'aglio, Pietro Bernardo
    De Lazzari, Manuel
    Vianello, Riccardo
    Iliceto, Sabino
    [J]. EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [4] TRANSVENOUS-SUBCUTANEOUS LEAD SYSTEM FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    HIEF, C
    PODCZECK, A
    VEIT, F
    FROHNER, K
    KALTENBRUNNER, W
    NURNBERG, M
    STEINBACH, K
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 1993, 105 (01) : 12 - 16
  • [5] INFECTIVE ENDOCARDITIS OF THE TRANSVENOUS LEAD OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    WERNER, GS
    GONSKA, BD
    HERSE, B
    KREUZER, H
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (01): : 51 - 54
  • [6] Technique for subcutaneous implantable cardioverter-defibrillator extraction
    Ip, James E.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (05) : 789 - 791
  • [7] Major predictors of fibrous adherences in transvenous implantable cardioverter-defibrillator lead extraction
    Segreti, Luca
    Di Cod, Andrea
    Soldati, Ezio
    Zucchelli, Giulio
    Viani, Stefano
    Paperini, Luca
    De Lucia, Raffaele
    Coluccia, Giovanni
    Valsecchi, Sergio
    Bongiorni, Maria Grazia
    [J]. HEART RHYTHM, 2014, 11 (12) : 2196 - 2201
  • [8] Implantable cardioverter-defibrillator lead performance
    Maisel, William H.
    Kramer, Daniel B.
    [J]. CIRCULATION, 2008, 117 (21) : 2721 - 2723
  • [9] SHOCK WITHOUT WIRES: A LOOK AT SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR COMPARED TO TRANSVENOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR FOR VENTRICULAR ARRHYTHMIAS
    Guice, K. C.
    Raja, J.
    Oberoi, M.
    Khouzam, R.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2021, 69 (02) : 493 - 493
  • [10] Shock Without Wires: A Look at Subcutaneous Implantable Cardioverter-Defibrillator Compared to Transvenous Implantable Cardioverter-Defibrillator for Ventricular Arrhythmias
    Raja, Joel
    Guice, Kenneth
    Oberoi, Mansi
    Whitwell, Samantha
    Asbeutah, Abdul Aziz
    Russell, Alex
    Khouzam, Rami N.
    [J]. CURRENT PROBLEMS IN CARDIOLOGY, 2022, 47 (09)