Migration of a Kirschner Wire From the Clavicle Into the Intrathoracic Trachea

被引:32
|
作者
Nakayama, Mitsuo [1 ]
Gika, Masatoshi [1 ]
Fukuda, Hiroki [1 ]
Yamahata, Takeshi [1 ]
Aoki, Kohei [1 ]
Shiba, Syugo [1 ]
Eguchi, Keisuke [1 ]
机构
[1] Saitama Med Univ, Dept Gen Thorac Surg, Saitama Med Ctr, Kawagoe, Saitama, Japan
来源
ANNALS OF THORACIC SURGERY | 2009年 / 88卷 / 02期
关键词
FRACTURE; SHOULDER; TAMPONADE;
D O I
10.1016/j.athoracsur.2008.12.093
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report a 70-year-old man who had a rare complication related to the insertion of Kirschner wires for fixation of a right clavicle fracture. Eight months after the placement of the Kirschner wires, he presented with cough and hemosputum. Chest roentgenograms, chest computed tomographic scans, and bronchoscopy revealed that one of the Kirschner wires had migrated through the lung and into the intrathoracic trachea. Immediate thoracotomy was performed to remove the wire. His postoperative course was uneventful. (Ann Thorac Surg 2009; 88: 653-4) (C) 2009 by The Society of Thoracic Surgeons
引用
收藏
页码:653 / 654
页数:3
相关论文
共 50 条
  • [31] MIGRATION OF KIRSCHNER WIRE FOLLOWING OSTEOSYNTHESES OF THE HIP
    BRADE, A
    HIPPE, P
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1981, 119 (01): : 80 - 84
  • [32] Intra-abdominal migration of a Kirschner wire
    Stalekar, Hrvoje
    Loncarek, Karmen
    Kovacevic, Miljenko
    WIENER KLINISCHE WOCHENSCHRIFT, 2010, 122 (5-6) : 140 - 140
  • [33] An Unusual Case of Kirschner Wire Migration in the Foot
    Kong, Roderick
    Mohamed, Mohamed
    Toh, Eugene
    JOURNAL OF FOOT & ANKLE SURGERY, 2016, 55 (05): : 1110 - 1112
  • [34] CARDIAC PERFORATION AFTER KIRSCHNER WIRE MIGRATION
    TUBBAX, H
    HENDZEL, P
    SERGEANT, P
    ACTA CHIRURGICA BELGICA, 1989, 89 (06) : 309 - 311
  • [35] Migration of Kirschner wires following fixation of the clavicle - a report of 2 cases
    Leppilahti, J
    Jalovaara, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (05): : 517 - 519
  • [36] Intratracheal migration of two Kirschner wires after surgery for a clavicle fracture
    Harmouchi, Hicham
    El Bouazzaoui, Abderahime
    Bensalah, Abdellatif
    Badr, Alami
    Lakranbi, Marwane
    Ouadnouni, Yassine
    Bouarhroum, Abdellatif
    Smahi, Mohammed
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2021, 29 (05): : 428 - 430
  • [37] MIGRATION OF KIRSCHNER PINS USED FOR STABILIZATION OF THE CLAVICLE - A REPORT OF 2 CASES
    JALOVAARA, P
    MYLLYLA, V
    LINDHOLM, RV
    ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (05): : 603 - 603
  • [38] Non-union of the clavicle after intramedullary nailing with a steel Kirschner wire
    Faymonville, C.
    Jubel, A.
    Schiffer, G.
    UNFALLCHIRURG, 2010, 113 (04): : 326 - 328
  • [39] Migration of a Kirschner Wire Into the Urinary Bladder: A Case Report
    Farion, Aleksei O.
    Paskov, Roman V.
    Dushin, Denis V.
    Bazarov, Alexander Yu.
    Prokopev, Aleksey N.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2023, 29 (02): : 118 - 125
  • [40] Tracheoinnominate artery fistula caused by migration of a Kirschner wire
    Wu, Yi-Hsuan
    Lai, Chao-Han
    Luo, Chawn-Yau
    Tseng, Yau-Lin